MAURY USCG vessel records Sign in
← All vessels

ICE HAWK

ICE HAWK is a 1999 tank ship. The Coast Guard has recorded 12 inspections since 2009, most recently in May 2012, along with 12 deficiencies and 7 operational controls.

Records from 2009 to 2012. Most recent: inspection, 30 May 2012.

Built
1999
Last inspected
30 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9169768 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1023003
Flag
LIBERIA
—
Maury page id
psix-1023003

Inspections, by type

…with no type recorded5
Years with a record 3 calendar years (2009–2012)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10321 - Simplified, Gross Ton
10321 - Convention (Subpart B), Gross Ton
5054 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

30 May 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4328369
27 May 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4324446
18 May 2012 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4314611
18 May 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4315272
1 May 2012 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4299280
5 November 2010 ISPS III Exam · In-Service Inspection · NPV Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3886917
25 October 2010 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3876998
15 October 2010 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3870500
7 October 2010 ISPS II Exam · Joint Vessel Security Verification (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3866159
26 July 2009 COC-CHEM Renew · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3546645
23 July 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3543498
10 July 2009 Joint Vessel Security Verification (Massena only) · ISPS II Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3533258

Deficiency record · 12

Fire Fighting › Fixed Fire Detection System › Indicator Light
Issued 18 May 2012 Resolved
Fire detection shall initiate audible and visual alarms in sufficient place to ensure the alarms are observed by a responsible officer of the Engine Room. Visual alarm does not operate in Engine Room upper level and machine shop. Solas Reg 7.4.2 16a
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 30 May 2012
Resolution: Recieved report from tech rep, master, and class stating that the def has been recitified.
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 May 2012 Resolved
All ships shall have a properly adjusted standard magnetic compass. Ships magnetic compass is off by thirty degrees. This will affect the proper navigation of the vessel. Soles Rag 19.2.1.1
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 30 May 2012
Resolution: Recieved report from tech rep, master, and class stating that the def has been recitified.
Navigation › Piloting/Steering › Gyro Compass
Issued 5 November 2010 Resolved
Gyro Compass not indicating true heading and displays varying headings while moored at pier. SOLAS (09 cons) Ch. V REG 19.2.5 17a
Action required: 705 - Other - as specified
Resolved 18 May 2012
Resolution: Gyro compass serivced and repair by certified tech.
Navigation › Piloting/Steering › Azimuth
Issued 5 November 2010 Resolved
Heading or track control system is not operable. SOLAS (09 cons) CH V REG 19.2.8.2 17a
Action required: 705 - Other - as specified
Resolved 18 May 2012
Resolution: Track control system was repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 5 November 2010 Resolved
Vessel has only one operational SSDG. #1 and #2 SSDG bearings are out of tolerance, readings provided by the ships crew. #1 SSDG needs spare parts for a complete overhaul. (SSDG #2 availible for emergency, bearing out of tolerance) SOLAS 04 CONS II-1 / 41.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2011
Resolved 18 May 2012
Resolution: All 3 Generator sets are operational.
Lifesaving › Inflatable Liferafts › Servicing
Issued 5 November 2010 Resolved
All liferafts on board are past the annual servicing date. SOLAS 09 CONS III / 8.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2011
Resolved 31 May 2012
Resolution: Received a letter from vessel''s flag state administration granting an extention for safety equipment servicing until 11 JUL 2012.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 5 November 2010 Resolved
The company did not complete annual internal audits, IAW companies SMS manual Chap.8. Last Audit (19FEB10). Intermediate verification surveys for SMC & ISSC are due no later than 14 APR 2011 and have not been scheduled.
Condition: Improper/Lack of Maintenance
Due 18 April 2011
Resolved 18 May 2012
Resolution: Class NKK conducted ISM audit.
Fire Fighting › Means of Escape › Number
Issued 5 November 2010 Resolved
07 EEBD's are non-operational (in-adequate pressure). Fire control plan requires a total of 35, vessel has only 28.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2011
Resolved 18 May 2012
Resolution: Vessel sent 07 EEBD''s to be serviced. See EEBD service report attached to act. # 4314611
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 November 2010 Resolved
Portable fire extinguishers have not been serviced annually. Servicing certificate expired 25 March 2011.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2011
Resolved 31 May 2012
Resolution: Received a letter from vessel''s flag state administration granting an extention for safety equipment servicing until 11 JUL 2012.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 November 2010 Resolved
Fixed CO2 extinguishing system has not been serviced annually , servicing certificate expired 24 March 2011.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2011
Resolved 31 May 2012
Resolution: Received a letter from vessel''s flag state administration granting an extention for safety equipment servicing until 11 JUL 2012.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 5 November 2010 Resolved
Company did not follow SMS procedure to maintain vessel in accordance with relevant rules and regulations. Objective evidence as follows: Only one SSDG operational and two in need of repair. All life rafts are past due for annual servicing. Portable and fixed fire extinguishing system are past due for annual servicing. 7 of the 35 required EEBD's not operational since Sept 2010. Ship’s crew n
Condition: Improper/Lack of Maintenance
Due 18 April 2011
Resolved 18 May 2012
Resolution: Vessel is under operation of new ISM Company. Class NKK conduct ISM audit.
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 July 2009 Resolved
Vessel requested LOD for 1 inoperable radar. Repair or replace and provide a certified technician's report prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2009
Resolved 31 July 2009
Resolution: Received tech report attesting to repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.