Records from 2017 to 2023. Most recent: inspection, 5 February 2023.
Inspection history · 10
5 February 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7632208
3 January 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7615558
26 November 2022
PSC B · COC-CHEM Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7599759
11 July 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7503835
25 November 2021
COE-Offshore · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7357503
25 November 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7357542
25 October 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6837297
24 October 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6841686
12 October 2017
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6286063
29 September 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6278174
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 November 2022
Resolved
FIRE PROTECTION SYSTEMS AND FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. SPRINKLER HEADS IN INERT GAS SPACE ARE CORRODED/COVERED BY CHRYSTALIZED SALT. GASKET ON SPRINKLER SYSTEM IN SAMPLE LOCKER SPACE IS DETERIORATED AND COVERED WITH CHRYSTALIZED SALT.
74 SOLAS(20) II-2/14.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2022
Resolved 5 February 2023
Resolution: Vessel's crew removed and replaced damage system components and then tested system to the satisfaction of the attending ABS Surveyor. Report atttached in Documents.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 25 November 2021
Resolved
FOR TANKERS OF 20,000 TONNES DEADWEIGHT AND UPWARDS ON OR AFTER 01 JUL 2002 BUT BEFORE 01 JANUARY 2016, THE PROTECTION OF THE CARGO TANKS SHALL BE ACHIEVED BY A FIXED INERT GAS SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE FSS CODE. INSTRUMENTATION SHALL BE FITTED FOR CONTINOUSLY INDICATING AND PERMANTLY READING WHEN THE INERT GAS IS BEING SUPPLIED: THE OXYGEN CONTENT OF THE INERT GAS IN THE INERT GAS SUPPLY MAINS ON THE DISCHARGE SIDE OF THE GAS BLOWERS. PSCO OBSERVED SECONDARY 02 ANALYZER ON THE INERT GAS MAINE THAT IS NOT REFLECTED ON CLASS APPROVED INERT GAS MANUAL.
74 SOLAS 2020 II-2/4.5.2.2 --- FSS CODE 15.2.4.2.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 July 2022
Resolution: Vessel provided proof that it removed the second, optional O2 analyzer that was not approved by class from the control space for the IG system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 October 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL IS INDICATING LOW INSULATION READINGS ON SWITCHBOARD POSING A PROBLEM WITH THE WIRING AND POWER DISTRIBUTION. 74SOLAS(14)1/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2019
Resolution: THE SOURCE OF THE LOW INSULATION READING ON SWITCHBOARD WAS DETERMINED AND APPROPRIATELY MITIGATED; INSULATION TESTING COMPLETED AND SYSTEM REPAIRED TO THE SATISFACTION OF THE ATTENDING SURVEYOR.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 25 October 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO WAS UNABLE TO TEST IGS AND IGG SYSTEM DUE TO LOW OXYGEN CONTENT IN IGG ROOM AND PROBLEMS WITH STARTING THE SYSTEM. 74SOLAS(14)1/11((a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2019
Resolution: THE COAUSE OF THE LOW OXYGEN CONTENT WAS DETERMINED TO BE A CRACKED BELLOWS. CRACKED BELLOWS REPLACED WITH NEW, IGS AND IGG SYSTEM RUN AT NORMAL OPERATING CONDITIONS; TESTED; AND FOUND SATISFACTORY TO THE ATTENDING SURVEYOR.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED POSSIBLE LEAK FORWARD OF THE STRIPPING PUMP AT FLANGE. 74SOLAS(14)1/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2019
Resolution: THE STRIPPING PUMP RUN AT NORMAL OPERATING PRESSURE AND NO LEAKS FOUND. AREA ADJACENT TO THE FLANGE CLEANED, EXAMINED AND FOUND IN NORMAL CONDITION. PUMP FOUND SATISFACTORY BY THE ATTENDING SURVEYOR.