← All vessels
PAX
Freight Ship · Bulk Carrier class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named PAX
PAX is a 2009 freight ship. The Coast Guard has recorded 13 inspections since 2009, most recently in April 2023, along with 6 deficiencies and 3 operational controls.
Records from 2009 to 2023. Most recent: inspection, 5 April 2023.
- Built
- 2009
- Last inspected
- 5 April 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9412622 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7UF6
1024594
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1024594
Inspections, by type
…with no type recorded2
Years with a record
9 calendar years (2009–2023)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it19846 - Convention (Subpart B), Gross Ton
10514 - Convention (Subpart B), Net Ton
32047 - Dead Weight, Ton
39550 - Displacement, Ton
10514 - Convention (Subpart B), Net Ton
32047 - Dead Weight, Ton
39550 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
5 April 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7663360
28 January 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7627516
24 January 2023
COE-Administrative · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7626124
13 January 2020
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6887988
12 January 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6885646
17 September 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6542031
15 October 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6022770
23 December 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5778841
15 October 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5005423
27 February 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4252046
15 February 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4238640
26 November 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3898966
21 July 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3537268
Deficiency record · 6
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 September 2018
Resolved
01-2035-Fire Protection System shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire portection including fire resisting divisions, and protection of openings and penetrations in these divisions.
06 A-class self closing doors were not operating in accordance with fire control plan.
(74) SOLAS 2009 CH. II-2 REG. 14.2.1.1.1
Engineering › Fuel Oil Service System › Piping
Issued 15 October 2014
Resolved
1499: External high-pressure fuel delivery lines shall be protected with jacketed piping capable of containing fuel from high-pressure failure. The main engine fuel lines do not have double-jacketed protection.
SOLAS 74 (04 cons) II-2/4.22.5.2 ---(17ac)
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 15 October 2014
Resolved
1499: The machinery shall be of a design and construction adequate for the service for which they are intended. The incinerator has no refractory and cracks on the unit casing.
SOLAS 74 (04 cons) II-1 / 26.1---(16ac)
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 15 October 2014
Resolved
1499: After any survey of the ship, no change shall be made in the structural arrangements, machinery, and equipment without the sanction of the administration. The vent duct has temporary drain pipe located in the bridge electrical room. SOLAS 74 (04 cons) I/11 (b)---(40ac)
Engineering › Compressed Air System (control) › Valve
Issued 15 October 2014
Resolved
1499: In every ship means shall be provided to prevent overpressure in any part of a compressed air system. Suitable pressure relief arrangements shall be provided for all systems. Start air systems receivers for main engine have no pressure relief valves. SOLAS 74 (04 cons.) II-1/34.1---(40ac)
Fire Fighting › Fixed Fire Detection System › Approval
Issued 15 October 2014
Resolved
0715: The function of the fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration. Vessel does not have appropriate means of testing the heat detection system. Crew uses a lighter to test heat detection. SOLAS 74 (04 cons.) II-2/7.3.2---(50c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.