RCC EUROPE is a 2009 freight ship. The Coast Guard has recorded 21 inspections since 2016, most recently in May 2026, along with 5 deficiencies and 3 operational controls.
Records from 2016 to 2026. Most recent: operational control imposed, 19 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it38050 - Displacement, Metric Ton 21021 - Dead Weight, Metric Ton 57692 - Convention (Subpart B), Gross Ton 57692 - Simplified, Gross Ton 21037 - Convention (Subpart B), Net Ton 21037 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 21
19 May 2026Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8376061
19 May 2026Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8376681
18 May 2026PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8371164
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 19 March 2026Resolved
EVERY SHIP TO WHICH CHAPTER 1 APPLIES SHALL CARRY AN APPROPRIATE PORTABLE ATMOSPHERE TESTING INSTRUMENT. SUITABLE MEANS SHALL BE PROVIDED FOR THE CALIBRATION OF SUCH INSTRUMENTS. PSCO OBSERVED THE CREW UNABLE TO PERFORM BUMP TEST PER MANUFACTURERS MANUAL, AND INCORRECT REGULATOR TO PERFORM IT.
74SOLAS(24)X1-1/7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Rcvd class report and cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 April 2022Resolved
THE MACHINERY, OTHER PRESSURE VESSEL ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AN DSHALL BE INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCO OBSERVED #2 GENERATOR HAD FUEL LEAKING FROM THE FUEL PUMP ON THE #7 CYLINDER.
74SOLAS(04)II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 April 2022Resolved
RESCUE BOATS SHALL BE STOWED IN A STATE OF CONTINUOUS READINESS FOR LAUNCHING IN NOT MORE THAN 5 MINUTES. [name withheld] BOAT COULD NOT BE STARTED AND EXCEEDED THE 5 MINUTE LAUNCH REQUIREMENT.
74SOLAS(20)III/14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2019Resolved
-40AC; Rectify def prior to next US port after sailing foreign.
-The machinery, associated piping sytems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed diesel oil leak on 3-way fuel filter valve on No. 2 generator. SOLAS 74 (2004 Cons) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2019
Resolution: Received, reviewed and accepted class report from DNV-GL satisfying the requirement. Ships crew replaced defective O ring.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 5 April 2016Resolved
2510: Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel does not have a ship specific Bio-Fouling Plan. 33CFR2050(g) & IMO Res 207(62, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: PSC personnel spoke with the [name withheld] and Chief Engineer about Ballast Water and Bio-Fouling documentation.