NAVIGATOR PEGASUS is a 2009 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in January 2024, along with 5 deficiencies and 4 operational controls.
Records from 2016 to 2024. Most recent: operational control imposed, 26 January 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it17807 - Regulatory (Subpart C or D), Gross Ton 5343 - Regulatory (Subpart C or D), Net Ton 17807 - Convention (Subpart B), Gross Ton 5343 - Convention (Subpart B), Net Ton 23640 - Dead Weight, Ton 33004 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
26 January 2024Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7856091
26 January 2024Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7857433
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 June 2021Resolved
"Electrical equipment, cables and wiring should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization." However, for locations not covered by such standards, electrical equipment, cables and wiring which do not conform to the standards may be installed in hazardous locations based on a risk assessment to the satisfaction of the Administration, to ensure that an equivalent level of safety is assured.
All ballast water electrical arrangements to include cables, glands, and enclosures are wasted away. 74SOLAS(20) VII/13.1 '93 IGC 10.1.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2021
Resolution: Received class report and photos attesting to successful repair of deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 June 2021Resolved
Each cargo tank should be provided with means for indicating level.
Starboard deck tank level indicator is inoperable.
74SOLAS(20) VII/13.1 '93IGC 13.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 July 2021
Resolution: Vessel provided documentation that this deficiency was rectified.
02 - Structural Conditions › N/A - No Subsystem › Safe access to tanker bows
Issued 22 June 2021Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the code to ensure that the ship will remain fit to proceed to sea without danger to ship or persons on board.
Catwalk supports forward of Tank 2 up to bow has wastage.
74SOLAS(20) VII/13.1 '93IGC 1.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 October 2021
Resolution: Received a class report attesting to repairs with pictures of the repairs.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 8 August 2016Resolved
The system and the dry chemical powder should be adequate for the purpose and satisfactory to the administration. Six pressure regulators require replacement. Require technician report prior to cargo ops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 August 2016
Resolution: Service technician boarded vessel and installed 7 N2 regulators, repaired 4 guages (2 high, 2 low) and set regulators to working pressure of 14 BAR.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 August 2016Resolved
Airlock doors should be self-closing. Three airlock doors were discovered to be non-self closing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2016
Resolution: The Airlock door's self-closing mechanism was overhauled. Properation operation was demonstrated.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.