MAURY USCG vessel records Sign in
← All vessels

CHIQUITA MERCHANT

CHIQUITA MERCHANT is a 2007 freight ship. The Coast Guard has recorded 45 inspections since 2012, most recently in April 2026, along with 21 deficiencies and 8 operational controls.

Records from 2012 to 2026. Most recent: inspection, 30 April 2026.

Built
2007
Last inspected
30 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9344631 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1026633
Flag
LIBERIA
—
Maury page id
psix-1026633

Inspections, by type

…with no type recorded9
Years with a record 13 calendar years (2012–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22914 - Convention (Subpart B), Gross Ton
9277 - Convention (Subpart B), Net Ton
37942 - Displacement, Metric Ton
28142 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

30 April 2026 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8358508
16 November 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8267960
13 November 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8268229
21 February 2025 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8082678
28 December 2024 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8051510
27 December 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8051239
11 August 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7977691
5 March 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7874456
13 February 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7864970
4 February 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7859102
23 January 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7853332
20 September 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7795402
30 July 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7753906
13 January 2023 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7619236
10 November 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7592727
8 July 2022 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7498537
22 June 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7484269
1 May 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7441548
4 April 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7424427
19 May 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7199003
11 January 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7122813
8 January 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7120833
11 October 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7075191
9 October 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7074577
26 September 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7065646
6 July 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6998099
19 November 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6856963
18 November 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6857738
14 November 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6579977
13 June 2016 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5906527
12 May 2016 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5873878
4 March 2016 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5828569
18 November 2015 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5766316
9 October 2015 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5741488
19 August 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5220790
8 August 2015 MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5209824
7 August 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5209785
6 August 2015 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5202227
24 October 2014 ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5011665
30 May 2014 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4874484
1 May 2014 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4843866
27 March 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4820722
19 February 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4244190
19 February 2012 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4247383
17 February 2012 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4246739

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 April 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2026
Resolution: Recieved class report attesting to repairs to fire doors
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2026 Resolved
LIFEBUOYS SHALL BE STOWED AS TO BE CAPABLE OF BEING RAPIDLY CAST LOOSE. PSCO OBSERVED LIFEBUOYS ON BOTH BRIDGE WINGS STOWED IN SUCH A WAY PREVENTING RAPID ABILITY TO BE CAST LOOSE. 74SOLAS(24)III/7.1.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2026
Resolution: CREW RE-INSTALLED LIFEBUOYS PROPERLY
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2026 Resolved
CYLINDERS MUST ALWAYS BE SECURED AND WHEN NOT IN USE, THEY MUST BE STOWED IN A RACK IN AN UPRIGHT POSITION WITH PROTECTION CAP IN PLACE. PSCO OBSERVED 44 COMPRESSED GAS CYLINDERS STOWED NOT IN RACKS AND UNSECURED IN BOSUN WOKRROOM, OXYGEN+ACETELYNE STORAGE SPACES, AND ON DECK. 46CFR147.60(b)(1)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2026
Resolution: Recieved class report attesting to proper stowage of bottles not discharges to shore.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 December 2024 Resolved
MAIN AND AUXILLIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. REPORTED AND ACKNOWLEDGED THAT THE GOVERNER FOR THE MAIN ENGINE IS NON-OPERATIONAL, OFFERING NO MEANS OF CONTROL OF THE ENGINE OTHER THAN LOCAL OPERATION.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2024
Resolved 2 January 2025
Resolution: Received Flag dispensation attesting to repair and proper operation of propulsion systems from remote location.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 4 February 2024 Resolved
Cargo Ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the code. 74SOLAS (20) III/31.2 The normal equipement of every rescue boat shall consist of a searchlight which can work continously for not less 3 hours. PSCO observed searchlight not readily available. LSA Code 5.1.2.2.11
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 February 2024
Resolved 4 February 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 February 2024 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed corrosion on the fixed CO2 nozzle. 74SOLAS (20) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 February 2024
Resolved 4 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 September 2020 Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED. VESSEL EXPERIENCED A LOSS OF PROPULSION WHILE MOORED.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 September 2020
Resolution: See attached Class Report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 July 2020 Resolved
The name and port of registry of the ship to which the rescue boat belongs shall be marked on each side of the recue boats bow in block capitals of the roman alphabet. PSCO observed that the free fall life boat did not have required marking.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 6 July 2020
Resolved 6 July 2020
Resolution: Corrected on the spot
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 May 2016 Resolved
01-0750 Fire prevention - Doors required to be self closing shall not be fitted with hold-back hooks. PSCO found four galley doors fitted with hold back hooks within the "A" class division. 74SOLAS(2004 Cons)II-2/9.4.2.2 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 May 2016
Resolved 13 June 2016
Resolution: Ship's crew removed hold-back hooks from the galley doors.
Lifesaving › Lifeboat › Markings
Issued 12 May 2016 Resolved
02-0610 Lifeboats-All lifesaving appliances of this part shall be fitted with retro-reflective material where it will assist in detection. PSCO found retro-reflective material on the free fall lifeboat's hull to be weathered, rendering it ineffective. 74SOLAS(2009 Cons)III/34 LSA Code 1.2.2.7 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 May 2016
Resolved 13 June 2016
Resolution: Ship's crew installed new retro-flective tape.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 8 August 2015 Resolved
74 SOLAS (2009 CONS.) CH I reg. 11 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. STBD diesel oil bunker station valve failed and replacement is not available.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 October 2015
Resolution: 09OCT15: Received DNV-GL classification survey report #37, stating 01 deficiency issued by Sector LA/LB in activity #5209824 has been rectified. The vessel was supplied with a new butterfly vale at the bunker station, and has been hydrostatically tested.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 27 March 2014 Resolved
01-1499 Other(Prop & Aux Machinery)- The condition of the ship shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found modification to lube oil drain line to bypass day tank with soft hose arrangement. 74SOLAS(2009 Cons) I/11 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: Lube oil soft hose bypass from storage tank was removed and the system is back to its original form.
Engineering › Feedwater/Condensate Water System › Drain
Issued 27 March 2014 Resolved
02-1499 Other(Prop & Aux Machinery)-The condition of the ship shall be maintained to conform with the provisions of the present regulations...Found bypass of condensate drain on #1 and #3 ship service generators. 74SOLAS(2009 Cons) I/11 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: Bypass on drains on #1 and #3 ship service generators were removed and new automatic drain valves were installed.
Engineering › Feedwater/Condensate Water System › Drain
Issued 27 March 2014 Resolved
03-1499 Other(Prop & Aux Machinery)-The condition of the ship shall be maintained to conform with the provisions of the present regulations...Found leaky oil flange on scupper drain line over shaft alley. 74SOLAS(2009 Cons) I/11 10C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2014
Resolved 27 March 2014
Resolution: Tightened flange to stop the slow leak on the drain line.
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 27 March 2014 Resolved
04-1499 Other(Prop & Aux Machinery)- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations...Found soft hose modification running from oily bilge tank to N/E SSAV BOX DRAIN TANK. Not of original design or construction. 74SOLAS(2009 Cons) I/11
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2014
Resolved 27 March 2014
Resolution: Removed soft hose from bilge tank
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 27 March 2014 Resolved
05-0830 Pipes wires(insulate) accident prevention-Proper lagging or shielding of such items as steam lines, exhaust pipes and compressor discharges which owing to their location and operating temperature, create a safety hazard. Lagging was wasted on #2 oil purifier line. ILO-147/PWSA 33USC1223(b)1 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: Lagging was replaced.
Accommodation/Occupational Safety › Ventilation › General
Issued 27 March 2014 Resolved
06-0999 Other(safety in general)-Means shall be provided for the crew to safely check the quantity of the fire-extinguishing medium in the containers. Found severed exhaust line in CO2 room which does not allow for proper air flow or ventilation. FSS Code 5.2.1.1.3 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: CO2 exhaust line was found in order and new exhaust fan installed.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 27 March 2014 Resolved
07-0945 Emergency lighting-Electrical services essential for safety will be endured under various emergency conditions. Found lighting above emergency fire pump inoperable, as well as lighting in bow thruster space. 74SOLAS(2009 Cons)II-1/40.1.2 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: Lights in the bow thruster room and in the emergency fire pump area was found in operational condition.
Documentation › Markings/Placards › Garbage Placard
Issued 27 March 2014 Resolved
08-2199 Other (MARPOL operational def.)-Every ship of 12 m or more in length overall and fixed or floating platforms shall display placards which notify the crew and passengers of the discharge requirements of regulations 3, 4, 5 and 6 of this Annex, as applicable. Vessel did not have incinerator placard. MARPOL V/9.1 40AC
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: Incinerator placard was placed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 27 March 2014 Resolved
09-2199 Other(MARPOL operational def.)-Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. Vessel did not have placard on the marine sanitation device. 33CFR159.59 40AC
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: Sewage placard placed with instructions.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 March 2014 Resolved
10-0520 Lighting-working spaces-All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Found lighting wiring disconnected and hanging on stern light and starboard side amidships light, creating safety hazard. 74SOLAS(2009 Cons)II-1/45/1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2014
Resolution: Ground wires and electrical connections of the emergency lighting in way of the life boat davit and starboard midship light were renewed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.