MAURY USCG vessel records
← All vessels

HORIZON THEANO

HORIZON THEANO is a 2009 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in April 2024, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2024. Most recent: inspection, 5 April 2024.

Built
2009
Last inspected
5 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 April 2024
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9407392
1026658
Flag
LIBERIA
Maury page id
psix-1026658

Documentation record

Tonnage as PSIX records it29828 - Convention (Subpart B), Gross Ton
13429 - Convention (Subpart B), Net Ton
50268 - Dead Weight, Metric Ton
60972 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

5 April 2024 Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7890484
15 September 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7312949
2 March 2021 COC-CHEM & TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7144739
20 February 2020 PSC B · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6910878
20 February 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6624466
16 September 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6541439
1 March 2018 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6363989
13 November 2017 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6306102
24 September 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6273490
24 September 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6273730
24 September 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331995
23 September 2017 COE-Offshore · COE-Administrative
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6269314
18 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6179286
11 June 2017 ISPS III Exam · COE-Dockside
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6171972
4 February 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6082780
6 October 2016 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6017438

Deficiency record · 3

Electrical › Electric Supply System (service) › Cable
Issued 6 October 2016 Resolved
0950 Electric Equipment in General. installations in hazardous areas shall be of an approved type acceptable to the administration. PSCO noted 3 lighting fixtures an both manifold stop buttons non intresnsically safe and in poor condition. No Flammable Cargo until fixed. SOLASII-1/45.5.4 IBC (2016) 10.1.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2016
Resolved 4 February 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 October 2016 Resolved
1730 Oily Water Seperating Equipment. Failure of the oil fitlering equipment shall be recordeed in the oil record book part 1. PSCO noted that crew was unable to conduct test of OWS due to broken 3 way diversion valve for testing. Crew failed to document. MARPOL I.17.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 9 October 2016
Resolution: Crew fixed valve and conducted operational tests while exam team was still on board.
Fire Fighting › Firemans Outfit › Axe
Issued 6 October 2016 Resolved
Axe with a handle provided with high voltage insulation. PSCO noted that the firemans outfits had exposed metal on the end of the handles. SOLAS 10.10.1.1 / FSS CODE 3.2.1.1.5.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 October 2016
Resolved 4 February 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.