← All vessels
SEASTAR TITAN
SEASTAR TITAN is a 2009 freight ship. The Coast Guard has recorded 19 inspections since 2010, most recently in July 2022, along with 10 deficiencies — 1 with no resolution recorded — and 6 operational controls.
Records from 2010 to 2022. Most recent: inspection, 16 July 2022.
- Built
- 2009
- Last inspected
- 16 July 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9406037 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZDQS6
1026763
Flag
GIBRALTAR
—
Maury page id
psix-1026763
Inspections, by type
…with no type recorded7
…past their stated due date1
Years with a record
10 calendar years (2010–2022)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it19972 - Convention (Subpart B), Gross Ton
10404 - Convention (Subpart B), Net Ton
38549 - Displacement, Metric Ton
30439 - Dead Weight, Metric Ton
10404 - Convention (Subpart B), Net Ton
38549 - Displacement, Metric Ton
30439 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 19
16 July 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7507982
19 March 2021
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7159132
9 February 2021
PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7130256
5 February 2021
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7136384
8 October 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7073854
25 September 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7065289
8 June 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6438203
19 March 2018
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6374609
28 November 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6312105
2 March 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6094066
21 February 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6091679
24 February 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5813550
22 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5819965
12 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5814025
26 December 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5787316
22 December 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5785981
16 October 2014
PII Safety Exam · COE-Offshore · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5003286
10 September 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4141044
6 October 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3864441
Deficiency record · 10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2021
Resolved
13199- OTHER (MACHINERY)-The machinery and other pressure vessels associated piping systems and futtings shall be of a design and construction adequate for the service and for which are intended. PSCO observed oil leak from wrench hydrolic tank for aft steering.
74 SOLAS(20) II-1/26
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 8 October 2020
No resolution recorded
OIL RESIDUE (SLUDGE) TANK(S) SHALL BE PROVIDED AND SHALL BE OF ADEQUATE CAPACITY, HAVING REGARD TO THE TYPE OF MACHINERY AND LENGTH OF VOYAGE, TO RECEIVE THE OIL RESIDUES (SLUDGE) WHICH CANNOT BE DEALT WITH OTHERWISE IN ACCORDANCE WITH THE REQUIREMENTS OF THIS ANNEX.
VESSEL MADE TEMPORARY REPAIRS TO HULL OF BILGE TANK. BILGE HOLDING TANK IS TO BE SECURED WHILE IN U.S. WATERS. VESSEL IS AUTHORIZED TO USE STERN TUBE LUBE OIL TANK WHILE TRANSITING. CAPACITY OF BILGE HOLDING TANK IS 28.60 M3, CAPACITY OF STERN TUBE LUBE OIL TANK IS 3.2 M3.
MARPOL 1/12.3.1
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 28 November 2017
Resolved
9800- Other (clearly hazardous)- Each transfer pipe system is to be tested under static liquid test at least 1.5 MAWP annually. Vessel failed to provide documentation of hydrostatic test of bunker lines. 33CFR156.170 c
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 November 2017
Resolved
9800- Other (clearly hazardous)- The vessel must maintain a copy of the VRP onboard. Vessel did not maintain a hard copy or electronic copy of the Non-tank Vessel Response Plan onboard. 33CFR155.5030 10c
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 28 November 2017
Resolved
9800- Other (clearly hazardous)-Doors required to be self closing shall not be fitted with hold back hooks. PSCO observed 4 A-0 self closing doors with permanent hooks attached. SOLAS 74a (2009) II-2/9.4.2.2 10c
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 November 2017
Resolved
3032-drills-In cases where more than 25% of the ship's personnel has been changed, a drill should be conducted within one week of the change. PSCO observed 100% crew change occurred on 20Nov17 and a security drill was not conducted within one week. SOLAS 74a (2009) XI-2/4.1 ISPS B/13.6 10c
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 2 March 2017
Resolved
1720-Control of discharge of oil-Each non-metallic transfer hose must not burst, bulge, leak, or abnormally distort under static liquid pressure at least 1.5 times the maximum allowable working pressure. Chief Engineer could not provide proof of hydrostatic testing of bunker lines. 33 CFR 156.170(c)(1) 10c
Engineering › Steering Gear System › Cable
Issued 24 February 2016
Resolved
1499-Other-Steering gear control shall be provided for the main steering gear compartment; by two independent control systems both operable from the navigation bridge. PSCO observed hydraulic lock alarm on #1 steering pump that automatically started #2 steering pump. Ships electrician identified a loose connection. PSCO's witnessed a satisfactory steering test in all modes independently.
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 16 October 2014
Resolved
0940 - Ballast fuel and other tanks - PSCO observed that the vessel had been conducting flow through ballast exchange despite their ballast water management plan stating that only the sequential method shall be used. Provide clarification from company as to which method is to be used to conduct ballast water exchange to the satisfaction of the USCG - 33 CFR 151.2035(a)(7).
Communications › Radio Communications › EPIRB
Issued 16 October 2014
Resolved
0672 - EPIRB's for survival craft - The PSCO observed that EPIRB located on port-side bridge wing had a hydrostatic release unit that had been expired for more than 4 months (expired in May 2014). Vessel had previously ordered the incorrect unit in June 2014. Provide proof of delivery & installment of hydrostatic release unit to the satisfaction of USCG - SOLAS 74 (09 am) IV 7.6.4.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.