MAURY USCG vessel records
← All vessels

MAVERICK

MAVERICK is a 1999 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in June 2025, along with 20 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 5 June 2025.

Built
1999
Last inspected
5 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1026770
Flag
UNITED STATES
Maury page id
psix-1026770

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

5 June 2025 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8139779
14 April 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8106272
13 January 2025 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8062707
23 August 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7987573
5 October 2023 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7802061
3 May 2023 Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7680169
4 May 2022 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7439807
27 April 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7184456
14 August 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7035628
16 May 2019 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6683590
25 April 2019 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637754
9 April 2019 DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637762
10 July 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375254
22 June 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105814
11 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105347
12 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829898

Deficiency record · 20

10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 5 June 2025 Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Operator log of passenger counts does not meet entirety of regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 28 July 2025
Resolution: Sec Bos OCMI policy decision made to require only passenger counts be kept on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 October 2023 Resolved
At least one life ring buoy must be fitted with a lifeline. Vessel's one and only life ring buoy was missing the normally attached lifeline and floating water light. Vessel is to attach a lifeline and floating water light to its' ring buoy that complies with the requirements of 46 CFR 180.70 prior to movement. 46 CFR 180.70(c) 46 CFR 180.70(d)
Action required: 60 - Rectify deficiencies prior to movement
Due 5 October 2023
Resolved 6 October 2023
Resolution: O/O sent objective evidence that the life line and water light has been re-attached to vessel's life ring buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 October 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by table 176.810(b), the owner or managing operator must provide satisfactory evidence of the required servicing of the system to the marine inspector. Annual servicing of vessel's installed fire-boy system was not conducted. O/O is to have the vessel's installed fire extinguishing system serviced IAW 46 CFR 176.810. 46 CFR 176.810(d)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 October 2023
Resolved 6 October 2023
Resolution: O/O provided objective evidence that the installed fire extinguishing system gas cylinder has been replaced with a cylinder that has been serviced annualy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2023 Resolved
The minimum number of fire extinguishers required on a vessel must be acceptable to the cognizant OCMI but must not be fewer than the minimum number of portable fire extinguishers required by Table 181.500(b). Vessel's portable fire extinguisher at the operating station was beyond it's life expectancy and is to be replaced. O/O is to install a 10B.C extinguisher at operating station. 46 CFR 181.500(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 October 2023
Resolved 6 October 2023
Resolution: O/O provided objective evidence that a new 10 B.C fire extinguisher has been purchased and installed at vessel's operating station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2023 Resolved
Portable fire extinguishers must be inspected and maintained IAW NFPA 10(incorporated by reference see 175.600). Monthly and annual inspections IAW NFPA 10 have not been conducted. O/O is to provide servicing/inspection records of the portable fire extinguishers on board. 46 CFR 176.810(b)(1)
Action required: 60 - Rectify deficiencies prior to movement
Due 5 October 2023
Resolved 6 October 2023
Resolution: O/O provided objective evidence that the fire extinguishers on board vessel have been inspected and serviced IAW NFPA 10.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 October 2023 Resolved
Vessels are to be able to provide proof of state registration on board at all times. Vessel was missing the original state registration certificate. 46 CFR 67.313
Action required: 60 - Rectify deficiencies prior to movement
Due 5 October 2023
Resolved 6 October 2023
Resolution: O/O provided objective evidence that the vessel has a valid state registration and proof of such is now on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 02 fire buckets and all three lanyards. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 6 October 2023
Resolution: O/O provided objective evidence that 3 fire buckets are now on vessel with proper stencilling and lanyards attached.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 October 2023 Resolved
Each vessel with an installed compass must have that compass be suitable and designed for marine use and mounted at the operating station. The vessel's installed magnetic compass was broken and inoperable. O/O is to install a properly functioning magnetic compass or remove compass completely from vessel. 46 CFR 184.402(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 2 November 2023
Resolution: O/O provided objective evidence that the magnetic compass was removed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 October 2023 Resolved
As appropriate for its' intended voyage each vessel is required to carry adequate and up to date charts. Vessel was missing the chartlet of operating area that is usually carried on board. 46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 2 November 2023
Resolution: O/O provided objective evidence that a chartlet of operating area was acquired and carried on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2022 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the OCMI. The 40-B:C fire extinguisher is not bracketed or supported.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
Resolution: Verified installation of approved bracket for fire extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2022 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that; the pump is permanently moored. The bilge pump is not secured in any way.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
Resolution: Verified bilge pump was mounted and secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2022 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that; positive shutoff valve is installed at the hull penetration. No shutoff valve at the discharge for bilge pump. Rectify prior to hullexam.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 August 2024
Resolution: Shutoff valve installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2022 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The operating station does not have an indication when the bilge pump is in auto operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
Resolution: Verified correct operation of the indicator light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022 Resolved
A vessel must be provided with an auxilitary means of steering, a suitable hand tiller may be acceptable. The vessel did not have any auxiliary steering.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
Resolution: Operator demostrated how to disconnect the hydraulic ram and control the rudder in the event of a loss of steering.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 May 2019 Resolved
Vessel was sold. Complete new to zone inspection prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2019
Resolution: Completed COI inspection in Sector Boston OCMI zone on 5/16/19.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2019 Resolved
Ring buoy is deteriorated and no longer servicable. Provide a new ring buoy and mark accordingly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2019 Resolved
Ring buoy light is missing. Provide a ring buoy light with 3-6' line with clip.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 April 2019 Resolved
Provide proof that the fixed fire extinguishing system was serviced within the last 5 years for a visual and external examination by a licensed fire servicing company.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2019
Resolution: Provided proof that the fixed fire extinguishing system was serviced within the last 5 years for a visual and external examination by a licensed fire servicing company
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 April 2019 Resolved
Bilge alarm is not working. Prove proper operation of the bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 April 2019 Resolved
Vessel missing portable lights. Provide adequate flashlight or equivalent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019

Ownership record