MAURY USCG vessel records
← All vessels

MSC RONIT R

MSC RONIT R is a 2005 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in February 2026, along with 4 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 27 February 2026.

Built
2005
Last inspected
27 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9293167
1026781
Flag
LIBERIA
Maury page id
psix-1026781

Documentation record

Tonnage as PSIX records it58960 - Convention (Subpart B), Gross Ton
31442 - Convention (Subpart B), Net Ton
86424 - Displacement, Ton
64519 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

27 February 2026 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8353927
24 February 2026 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8312198
16 December 2024 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8045090
6 June 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7928866
12 March 2024 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7875425
29 January 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7922395
9 November 2023 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7822025
19 March 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7652470
13 December 2021 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7367220
4 November 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7090101
10 September 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7054992
5 December 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6864768
31 July 2017 Ballast Water Examination · Administrative Inspection · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6226221
10 March 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5831025

Deficiency record · 4

03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 24 February 2026 Resolved
THE INTERNATIONAL LOAD LINE CERTIFICATE SHALL NOT BE DELIVERED TO THE SHIP UNTIL THE OFFICER OR SURVEYOR ACTING UNDER THE PROVISIONS OF ARTICLE 13 OF THE CONVENTION HAS CERTIFIED THAT THE MARKS ARE CORRECTLY AND PERMANENTLY INDICATED ON THE SHIP'S SIDES. PSCO OBSERVED VESSEL LOAD LINE DEPICTED THE FRESH WATER MARK, WHICH DID NOT MATCH THE VESSEL'S CERTIFICATE WHICH HAD BOTH SUMMER AND FRESH INDICATED. ICLL REG 9 40AC
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 February 2026
Resolved 27 February 2026
Resolution: Recieved copy of new Load Line Certificate from Class, accurately reflecting current Load Line.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 March 2024 Resolved
A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM REQUIRED IN THIS REGULATION AND OTHER REGULATIONS IN THIS PART SHALL BE OF AN APPROVED TYPE AND COMPLY WITH THE FIRE SAFETY SYSTEMS CODE. THE ACTIVATION OF ANY DETECTOR SHALL INITIATE A VISUAL AND AUDIBLE FIRE DETECTION ALARM SIGNAL AT THE CONTROL PANEL AND INDICATING UNITS. ; SMOKE DETECTORS IN ENGINE CONTROL ROOM WERE NOT ACTIVATING ANY ALARMS IN FIRE DETECTION PANEL. (74 SOLAS, 2020 CONS., II-2/7.2.2 ; FSS CODE 9.2.5.1.1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 May 2024
Resolved 31 May 2024
Resolution: Vessel provided class report attesting to operational test of fixed fire detection system.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 March 2024 Resolved
ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. DURING LOCAL OPERATIONAL TEST OF STEERING SYSTEM, A PORT DRIFT OF 2.5 DEGREES PER MINUTE WAS OBSERVED WHILE ATTEMPTING TO HOLD 20 DEGREES ON PORT. OTHER ANGLE POSITIONS WERE NOT ABLE TO HOLD POSITION EITHER. SOLAS II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 May 2024
Resolved 31 May 2024
Resolution: Vessel provided a class report attesting to steering system repairs, test sat.
Fire Fighting › Ventilation Systems › Fans
Issued 1 August 2017 Resolved
0599 Other Working Spaces - Ships shall be maintained in compliance with mechanical and electrical requirements of a classification society. The ventilation of the CO2 room is not operational. The space could not be inspected. SOLAS 74 (2004 Cons) II-1/3-1.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 August 2017
Resolved 3 August 2017
Resolution: DNV_GL Classification report submitted attesting to the operational status of the CO2 room ventilation.

Ownership record