CONTI CORTESIA is a 2005 freight ship. The Coast Guard has recorded 32 inspections since 2016, most recently in April 2026, along with 4 deficiencies and 10 operational controls.
Records from 2016 to 2026. Most recent: inspection, 23 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it90494 - Convention (Subpart B), Gross Ton 134888 - Displacement, Metric Ton 100864 - Dead Weight, Metric Ton 55452 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 32
23 April 2026Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8351819
18 April 2026Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8351818
13 February 2026In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8307784
8 February 2026Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8307798
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 25 February 2019Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background and in b lack on a light background. They shall also be permanently marked on the sides of the ships to the satisfaction of the Administration. The marks shall be plainly visible and if necessary, special arrangements shall be made for this purpose. Load line markings on sides of the ship found printed but not permanently affixed. ILLC 2005 Edition Ch. I/Reg 8. 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 28 February 2019
Resolution: Received Class Report indicating correction of this deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 September 2018Resolved
The machinery systems shall be adequate for the service for which they are intended.Vessel experienced a reduction of propulsion while attempting to depart from berth at Bayport Container Terminal.
74 SOLAS (04) II-I/26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: PSC HOU received class report attesting to satisfactory repairs of main engine fuel pump.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 3 February 2018Resolved
0750: Means shall be provided to control leaks of flammable liquids. The fuel source for the emergency generator has a leak at the sight glass. SOLAS(04) II-2 Reg 4.1.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 9 March 2018
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2018
Resolved 25 January 2018
Resolution: Received tech report.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.