MAURY USCG vessel records Sign in
← All vessels

SATIGNY

SATIGNY is a 2009 freight ship. The Coast Guard has recorded 10 inspections since 2009, most recently in May 2012, along with 16 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 2009 to 2012. Most recent: operational control imposed, 11 May 2012.

Built
2009
Last inspected
11 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9522738 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1026957
Flag
MALTA
—
Maury page id
psix-1026957

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (2009–2012)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it5087 - Convention (Subpart B), Gross Ton
2625 - Convention (Subpart B), Net Ton
7390 - Dead Weight, Ton
9996 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

11 May 2012 PI Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4308206
11 May 2012 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4308221
17 February 2012 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4241315
29 August 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4126903
5 July 2011 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4058740
1 July 2011 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4059353
22 February 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3950102
11 February 2011 COE-Dockside · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3943310
1 December 2009 ISPS I Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3641574
1 December 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3642765

Deficiency record · 16

Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 29 August 2011 Resolved
1220 Load Line rings, lines; Letters shall be painted in white or yellow on a dark background and shall be plainly visible. The ships deckline was not painted or plainly visible. Loadline Reg 8. 10c
Action required: 705 - Other - as specified
Due 29 August 2011
Resolved 29 August 2011
Resolution: Corrected on site.
Documentation › Logs/Records › Oil Record Book
Issued 11 February 2011 Resolved
After observing suspicious entries in the Oil Record Book (ORB), Port State Control Examiners (PSCE) expanded the scope of the engine room examination.The OCM was reading 30 ppm after the OWS was energized.The PSCE provided guidance to the C/E on the procedures for calibration using the OCM manual. The Elec calibrated the OCM and it read 15ppm afterwards. Failure to document equip failure in ORB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: New OCM installed on vessel
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 February 2011 Resolved
[name withheld] admitted making unauthorized modifications to the circuits in the OCM. Upon inspection by the PSCE, the tamper seal was missing on the OCM and the circuuit board had a 1/4 inch hole in the bottom left side where the electrician stated electrical components were removed. Vessel Detained (30 a&c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: New OCM installed on vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 February 2011 Resolved
The Chief Engineer has not conducted OWS preventative maintenance IAW the vessel's Safety and Environmental Manual chapter 10.2 (OWS). (30 a&c).
Action required: 705 - Other - as specified
Resolved 19 February 2011
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 February 2011 Resolved
The vessel's OCM was inoperable on 27SEP10. The master stated that he requested that the Company provide for a technician to come onboard but was told by the company that it was too expensive and that he should have the crew fix the OCM. MEPC 107(49) requires that the manufacturer of the OCM be the only personnel to fix and calibrate the OCM. Vessel Detained (30 a&c).
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: New OCM installed on vessel.
Construction/Loadline › Structures › Door
Issued 11 February 2011 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. Self closing door on 2nd deck leading to the stairway is not self closing. Vessel Detained (30 a&c). SOLAS 2009 Cons. Ch II-2 Reg 9.2.3.4.1
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: New self-closing devices have been installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 February 2011 No resolution recorded
Doors fitted in boundary bulkheads of machinery spaces of Category A shall be reasonable gas tight and self-closing. The two doors leading from the engine room to the engine control room are not self closing. Vessel Detained (30 a&c). SOLAS 2009 Cons. Ch. II-2 Reg 9.4.2.1
Action required: 705 - Other - as specified
Resolution: Nes self-closing devices have been installed.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 11 February 2011 Resolved
The fire alarm located next to the boiler on the upper deck of the engine room is inoperable. Vessel Detained (30 a&c). SOLAS 2009 Cons. Ch II-2 Reg 7.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2011
Documentation › Logs/Records › Oil Record Book
Issued 11 February 2011 Resolved
The [name withheld] weekly tank soundings do not match the tanks used for the collection and disposal of oil residues specified on the new IOPP Supplemental Form. The IOPP lists four tanks, while there are only sounding records for three tanks in the Oil Record Book. Vessel Detained (30 a&c).
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: L/O Sludge tank is of a design making it unable to be sounded, tank removed from IOPP.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 February 2011 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2011
Resolution: Corrected, Second Officer arrived by plane at ERT.
Engineering › Generator (propulsion/auxiliary-electric) › Cable
Issued 11 February 2011 Resolved
The cable attached to the emergency fuel shut-off handle for the emergency generator is frayed and in need of repair. Prior to departure for port (17 a&c).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2011
Resolution: Cable replaced
Operations/Management › Ballast Water Managment › Submission of Report
Issued 11 February 2011 Resolved
The Master did not report the vessel's condition in regards to Ballast Water to the NBIC 24 hours prior to arrival in Sector Hampton Roads RNA IAW ballast water reporting requirements (Master has not made any ballast water notifications in any US Port). Prior to departure (17c).
Action required: 705 - Other - as specified
Resolved 19 February 2011
Stability › Weathertight Integrity › General
Issued 11 February 2011 Resolved
The center window on the Navigation Bridge is shattered. These windows must be weather-tight and of approved construction. Repair prior to departure (17 a&c).
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: Window replaced.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 11 February 2011 Resolved
The above deficiencies indicate the ship's Safety Management System is not effectively implemented. An external audit is requested. Prior to departure (17 a&c).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2011
Resolution: Audit carried out on 19FEB11
Engineering › Steering Gear System › Pump
Issued 11 February 2011 Resolved
Steering gear pump 1 and 2 both have gauges that are inoperable. SOLAS 2009 Cons. Ch. II-I Reg 30.1
Action required: 705 - Other - as specified
Due 25 February 2011
Resolved 19 February 2011
Resolution: Both gauges replaced
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 February 2011 Resolved
The Chief Engineer and the electrician were unable to provide 18 months of OWS monitoring equipment data from the OCM. The Chief Engineer did not document the failure of the OCM data equipment. (30a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 February 2011

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.