MAURY USCG vessel records Sign in
← All vessels

ATLANTIC MAZATLAN

ATLANTIC MAZATLAN is a 2000 freight ship. The Coast Guard has recorded 11 inspections since 2006, most recently in May 2016, along with 6 deficiencies and 4 operational controls.

Records from 2006 to 2016. Most recent: inspection, 22 May 2016.

Built
2000
Last inspected
22 May 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9227792 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SINGAPORE
—
Maury page id
psix-10273

Inspections, by type

…with no type recorded4
Years with a record 5 calendar years (2006–2016)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it58136 - Displacement, Metric Ton
50296 - Dead Weight, Metric Ton
27986 - Convention (Subpart B), Gross Ton
17077 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

22 May 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5883223
23 March 2016 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5837254
23 November 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5768442
23 November 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5770679
15 September 2015 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5719514
25 March 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4822989
24 March 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4822388
18 October 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3082345
19 January 2006 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2568994
18 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2569311
14 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2567075

Deficiency record · 6

Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 23 March 2016 Resolved
2099-(Solas Operational Def.)- Vessel procedures for conducting enclosed space entry and rescue drill contained in the Vessels Procedures Manual (VPM) do not include all elements listed within SOLAS as required. 74 SOLAS(14am)III/19.3.6, Action Taken 50a
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 24 March 2016
Resolution: PSC NOLA received a class report from PACC SHIPPING satisfying the requirement
Engineering › Diesel Engine (auxiliary) › Air Silencer
Issued 15 September 2015 Resolved
0999 - Safety - The machinery and associated pipping shall be of a design and construction adequate for the service for which they are intended. PSCO observed a leak on the exhaust piping upon start up of the emergency generator. 74 SOLAS (01) II-1 Reg 26
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 October 2015
Resolved 19 September 2015
Resolution: Received, reviewed, and accepted documentation from Master satisfying the requirement.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 September 2015 Resolved
0715 - Detection - Fire detection and fire alarm systems shall be kept in good working order so as to ensure their required performance. PSCO observed a broken smoke detector hanging from its bracket over the #2 ships service generator. 74 SOLAS (01) II-2 Reg 14
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 16 September 2015
Resolution: Crew had ordered and installed during this exam. PSCO verified proper operation of the newly installed smoke detector head.
Navigation › Piloting/Steering › Gyro Compass
Issued 25 March 2014 Resolved
Gyro-Compass was not operable and needed to be corrected.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2014
Resolution: Received, reviewed ,and accepted Tech report. technician replaced inverter, reassembled gyro and restored power to the unit. satisfactory test completed. Equipment is now operational.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 19 January 2006 Resolved
One of the three fireman's suits is in poor condition. It must be replaced or repaired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 January 2006
Resolved 24 January 2006
Resolution: Received class report stating fireman''s outfit was replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 January 2006 Resolved
The main engine lube oil cooler salt water outlet pipe has two temporary patches and needs to be repaired or replaced.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 24 January 2006
Resolution: Received class report stating pipe was cropped and renewed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.