GERDA MAERSK is a 2009 freight ship. The Coast Guard has recorded 30 inspections since 2016, most recently in April 2026, along with 12 deficiencies and 5 operational controls.
Records from 2016 to 2026. Most recent: inspection, 23 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it127015 - Dead Weight, Metric Ton 99002 - Convention (Subpart B), Gross Ton 57019 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 30
23 April 2026Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8354979
6 March 2026PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8320689
18 July 2025PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8188802
19 November 2024PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8036614
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 May 2023Resolved
Means shall be provided to control leaks of flammable liquid. PSCO observed hydraulic oil accumulation under no. 01 and no. 02 diesel service generators. Additionally, PSCO observed lubrication oil accumulation under the no. 03 diesel service generator and fuel oil accumulation under no. 11 main engine cylinder head.
74 SOLAS(20) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 22 May 2023
Resolved 22 May 2023
Resolution: Master provided class report attesting that the deficiency had been rectified.
After any survey of the ship under regulations 7,8,9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. Port side anchor unable to deploy due to damaged anchor winch gear/shaft.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 December 2020
Resolution: The fractured intermediate gear shaft of port side anchor windlass was repaired by ship crew. The operation test of port side windlass conducted/SAT. Class (ABS) rpt received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2018Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Temporary repair was made on the lower stern tube.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2018
Resolved 5 September 2018
Resolution: Recieved technician report and class report allowing the vessel to proceed as is until next dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2018Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Five temporary repairs were made on the sewater cooling system supply.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 5 September 2018
Resolution: Recieved technician report and class report allowing the vessel to proceed as is until next dry dock.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 September 2018Resolved
After any survey of the ship under paragraph 1 has been completed, no change shall be made in equipment systems or fittings covered by the survey without the sanction of the administration. Sensors and fittings were removed from purifier sludge pumps. This could allow for the release of sludge into the engine room and could pose an electrical hazard to personnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 5 September 2018
Resolution: Recieved technician report and class report allowing the vessel to proceed as is until next dry dock.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 25 May 2017Resolved
CODE: 1715 CITE: 74SOLAS(2014 CONS.)II-2/14.2.1.1.2 ACTION: 10 a.c.
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. HEAT DETECTOR ABOVE AUXILLARY GENERATOR IS INOPERABLE.
Due 25 May 2017
Resolved 25 May 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 May 2017Resolved
CODE: 0750 CITE: 74SOLAS(2014 CONS.)II-2/9.4.2.1 ACTION: 40 a.c.
DOORS FITTED IN BOUNDRY BULKHEADS OF MACHINERY SPACES OF CATEGORY "A" SHALL BE SELF-CLOSING. SELF-CLOSING DOOR LEADING TO AUXILLARY GENERATOR ROOM WAS FOUND WITH CLOSING DEVICE REMOVED.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 June 2017
Resolved 23 June 2017
Resolution: See attached Class Report.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 25 May 2017Resolved
CODE: 1470 CITE: 74SOLAS(2014 CONS.)II-2/3.1.1 ACTION: 40 a.c.
INSULATING MATERIALS SHALL BE NON-COMBUSTIBLE. INSULATED PIPING ON MAIN ENGINE WAS FOUND WITH OIL SOAKED LAGGING.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 June 2017
Resolved 23 June 2017
Resolution: See attached Class Report.
Engineering › Pressure Vessel › Piping
Issued 28 March 2016Resolved
74SOLAS(04 CONS.)II-1/26.1 40ac Multiple steam pipes found leaking at the bunker oil heating system, in the fuel oil purifier room & in the steam turbine room. SEE NARRATIVE FOR SITE INFORMATION
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2016
Resolution: See attached Class Report.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 28 March 2016Resolved
74SOLAS(09 CONS.) II-2/2.2.1.3 40ac In order to achieve fire safety objectives set out in paragraph 1, the following functional requirements are embodied in the regulations of this chapter as appropriate: restricted use of combustible materials. Fuel soaked lagging found in multiple locations throughout the engine room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2016
Resolution: See attached Class Report.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2016Resolved
74SOLAS (14) II-1/40.3 40ac Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Exposed electrical wiring (non energized) found in multiple locations throughout the engine room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2016
Resolution: Seee attached Class Report.
74SOLAS (14) II-1/40.3 40ac Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Light fixture in the engine room found damaged causing wires to be exposed and found with cracked cover.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2016
Resolution: See attached Class Report.