MAURY USCG vessel records Sign in
← All vessels

BERKSHIRE

BERKSHIRE is a 2008 tank ship. The Coast Guard has recorded 18 inspections since 2010, most recently in January 2022, along with 8 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 2010 to 2022. Most recent: inspection, 12 January 2022.

Built
2008
Last inspected
12 January 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9369760 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1028432
Flag
LIBERIA
—
Maury page id
psix-1028432

Inspections, by type

…with no type recorded8
Years with a record 8 calendar years (2010–2022)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23032 - Regulatory (Subpart C or D), Gross Ton
6009 - Regulatory (Subpart C or D), Net Ton
23032 - Convention (Subpart B), Gross Ton
6909 - Convention (Subpart B), Net Ton
26446 - Dead Weight, Ton
37125 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

12 January 2022 COC-GAS Annual · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7379416
30 March 2021 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7165670
26 January 2021 PSC B · COC-GAS Renew · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7126602
19 July 2017 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6213769
19 May 2017 ISPS III Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6144794
23 October 2016 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6027904
3 March 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5826569
18 January 2016 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5799154
31 July 2015 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5202280
23 July 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4387474
17 May 2012 Type not recorded
No type recorded · Station Port OConnor · USCG Heartland District (CGD-H) · Activity 4314644
18 August 2011 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4116007
16 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4117514
16 February 2011 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3946484
14 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3942194
22 November 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3896763
20 October 2010 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3871408
11 October 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3867755

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 January 2022 Resolved
On ships carrying flammable and/or toxic products, a water-spray system for cooling, fire prevention and crew protection shall be installed to cover exposed cargo tank domes and expose on-deck storage vessels for flammable or toxic products. PSCO observed approximately 15 spray nozles not functional. Areas on the #1 cargo tank dome, port deck tank, starboard deck tank are not providing adequate water coverage. 74 SOLAS (20) VII/13.1 IGC (1993) 11.3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2022
Resolution: Vessel submitted class report and photos attesting to proper operation of deck nozzles.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 January 2021 Resolved
Vessels #1 cargo compressor motor was replaced and electrical splice completed in fabricated plywood shield for main power supply to the motor. Class not notified of replacement or modification.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2021
Resolved 30 January 2021
Resolution: Vessels classification society approved a more stout box protecting the spliced connection, and issued a condition prohibiting the use of the #1 cargo compressor/motor. Motor to be replaced with original no later than 28APR21.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 26 January 2021 Resolved
Cargo tank #3 and #2 starboard side guaging device wiring found to be exposed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2021
Resolved 30 January 2021
Resolution: Vessel repaired damaged fittings to the satisfaction of the attending class surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 26 January 2021 Resolved
Vessel failed to fully implement the SMS as evident by deficiency #1, an internal audit is required within 3 months.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 April 2021
Resolved 30 March 2021
Resolution: Recieved Liberian Flag report of ISM audit compliance.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 May 2017 Resolved
0111-All electric cables and wiring external to equipment shall be so installed as not to impair their original flame-retarding properties. The wiring leading to the instrinsically safe light fixture in way of the cargo motor room entrance is loose from what appears to be inadequate repairs or installation. 74 SOLAS (2004) II-1/45.5.2 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Lighting fixture repaired to manufacturer specifications.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 18 August 2011 Resolved
2510; Ship has two different Ballast Water Management Plans. Ballast Water handling log forms being used are not approved for use as per ISM. And recording of exchange are not on approved forms.
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 18 August 2011
Resolution: Discussed with the Captain and [name withheld].
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 August 2011 Resolved
0371; Inventory of medical equipment and medicines is poor. Cold medicines have not been accounted for. Thermometers have not been listed on inventory list and eyewash on bridge is dirty.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 18 August 2011
Resolution: Discussed with the Captain and [name withheld].
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 August 2011 Resolved
2055; Fire and lifesaving manuals have not been kept up to date. Instructions for response to fires has been changed but not approved by the company. Hydrostatic release for life rafts is not the type listed in manual.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 18 August 2011
Resolution: Discussed with the Captain and [name withheld].