Records from 2017 to 2025. Most recent: inspection, 4 February 2025.
Inspection history · 7
4 February 2025
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8072817
27 January 2022
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7381897
17 September 2019
NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6813375
2 October 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6546155
18 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6483916
7 March 2017
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6100119
13 February 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6087228
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 4 February 2025
No resolution recorded
TO ASSIST IN CASUALTY INVESTIGATIONS, SHIPS, WHEN ENGAGED ON INTERNATIONAL VOYAGES, SUBJECT TO THE PROVISIONS OF REGULATION 1.4, SHALL BE FITTED WITH A VOYAGE DATA RECORDER (VDR). PSCO OBSERVED INOPERABLE VDR.
SOLAS (2020) V REG 20.1
40 A&C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 13 February 2017
Resolved
0371: Each enclosed space entry and rescue drill shall include checking and use of rescue equipment and procedures. The stretcher on board is not adequate for the removal of a person from a confined space, 74 SOLAS (14) III/19.3.6.2.4, 17c.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2017
Resolved 14 February 2017
Resolution: A [name withheld] type stretcher was purchased and placed on board.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 February 2017
Resolved
1499: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or the persons on board. The vessels incinerator has a 5cm crack on the upper left corner of the opening. Also the auxiliary pump sea water supply line; See Narrative
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 7 March 2017
Resolution: Corrected by the crew.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 13 February 2017
Resolved
2510: Vessel must maintain a Ballast Water Management Plan that has been designed specifically for the vessel that will allow those responsible to understand and follow. Crew is not properly documenting items including Bio-Fouling and sediment procedures, 33CFR151.2050(g), 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Resolution: Reviewed procedures with the Captain, [name withheld], Chief Engineer [name withheld] and Third Mate.