MRC NAZENDE is a 2009 tank ship. The Coast Guard has recorded 27 inspections since 2016, most recently in March 2026, along with 13 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 2016 to 2026. Most recent: inspection, 7 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it30010 - Regulatory (Subpart C or D), Gross Ton 30010 - Convention (Subpart B), Gross Ton 13607 - Regulatory (Subpart C or D), Net Ton 13607 - Convention (Subpart B), Net Ton 51291 - Dead Weight, Metric Ton 54923 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
27 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 27
7 March 2026Deficiency Check · Administrative Inspection
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 January 2026Resolved
The foam concentrates of low-expansion foam fire extinguishing systems shall be approved by the administration based on the guidelines adopted by the organization.
PSCO Observed the foam analysis conducted on 23 June 2025 states that the foam needs further investigation and replacement is recommended. Solas (74) II-2/10.8.1.1 / FSS Code 6.4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2026
Resolved 7 March 2026
Resolution: Recieved satisfactory tech repot
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 May 2025Resolved
IN MEETING THESE REQUIREMENTS, THE COMPANY SHOULD ENSURE THAT: ALL NON-CONFORMITIES ARE REPORTED WITH ITS POSSIBLE CAUSE IF KNOWN, AND APPROPRIATE CORRECTIVE ACTION IS TAKEN.
THE TECHNICAL AND OPERATIONAL NATURE OF DEFICIENCIES 2-6 AND 8 PROVIDE OBJECTIVE EVIDENCE OF FAILURE, OR LACK OF EFFECTIVENESS OF THE IMPLEMENTATION OF THE ISM CODE. ADDITIONALLY, PSCO OBSERVED FIXED GAS TURNED OFF, 02 LOGS FOR CARGO TANKS INNACURATE, AND CREW UNABLE TO CALIBRATE PORTABLE METERS.
AN INTERNAL SAFETY MANAGEMENT AUDIT IS REQUIRED WITHIN 90 DAYS.
74SOLAS(20)IX/13.1
ISM CODE 10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2025
Resolved 1 July 2025
Resolution: AUDIT IN DOCUMENTS.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2025Resolved
ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ADMINISTRATION
PSCO OBSERVED IMPROPERLY INSTALLED EX LIGHT ON DECK FORWARD OF ACCOM, AND WASTED CABLE RUNS ABOVE CARGO TANK 4S
74SOLAS(20)II-1/45.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2025
Resolution: Class report that deficiency has been rectified
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 May 2025Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS.
PSCO OBSERVED ACTIVE FUEL OIL LEAKS ON AUX BOILER, AROUND A/E 3 FLYWHEEL, AND UNDERNEATH A/E 2 LO COOLER. ADDITIONALLY, PSCO OBSERVED LEAKING HYDRAULIC OIL ON STBD ANCHOR WINDLASS.
74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2025
Resolution: Class report submitted that deficiency was cleared.
PROVISIONS SHALL BE MADE TO GUARD AGAINST LIQUID RISING IN THE VENTING SYSTEM. THIS SHALL BE ACCOMPLISHED...TOGETHER WITH INDEPENDANT GAGING DEVICES.
PSCO OBSERVED ULLAGE SENSOR ON CARGO TANK 1P INOPERABLE. ADDITIONALLY, PSCO OBSERVED ASSOCIATED AUDIBLE ALARM BUZZER FABRICATED WITH CLIP FOR EASY DISCONNECTION TO BYPASS ALARM.
74SOLAS(04)II-2/11.6.3.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 May 2025
Resolution: Downgraded to 40ac as class report verified that parts are ordered and that there is adequate mitigations.
Master provided Class attetation and technician report confirming repaoir/satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 May 2025Resolved
THE PROTECTION OF CARGO TANKS SHALL BE ACHIEVED BY A INERT GAS SYSTEM IAW THE FSS CODE.
A GAS REGULATING VALVE SHALL BE FITTED IN THE INERT GAS MAIN. IT SHALL BE CAPABLE OF AUTOMATICALLY REGULATING THE FLOW OF INERT GAS TO THE CARGO TANKS.
PSCO OBSERVED GRV TO ATMOSPHERE TAKEN APART, ONLY CAPABLE OF BEING OPERATED BY HAND.
74SOLAS(04) II-2/4.5.5.1.1
FSS CODE 15.2.3.1.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 July 2025
Resolution: DOCUMENTS IN MISLE.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 May 2025Resolved
THE PROTECTION OF CARGO TANKS SHALL BE ACHIEVED BY A INERT GAS SYSTEM IAW THE FSS CODE.
THE AUDIBLE AND VISUAL ALARM ON THE LOW LEVEL OF WATER IN THE WATER SEAL SHALL OPERATE AT ALL TIMES.
PSCO OBSERVED INOPERABLE LOW LEVEL ALARM ON THE DECK WATER SEAL.
74SOLAS(04)II-2/4.5.5.1.1
FSS CODE 15.2.2.3.1.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2025
Resolution: Class report received that deficiency was rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 5 May 2025Resolved
THE RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK BACKGROUND.
PSCO OBSERVED UNPAINTED MARK FOR FRESHWATER LOADLINE ON PORT SIDE.
ICLL REG 8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2025
Resolution: Class report received that deficiency has been rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2025Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED.
PSCO OBSERVED DISCONNECTED GROUND WIRE ON LIGHT FIXTURE ABOVE IGG. ADDITIONALLY, PSCO OBSERVED BARE CONDUCTORS ON AUX BOILER BURNER, GEN LO COOLER, AND NO 2 HFO PURIFIER.
74SOLAS(04)II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2025
Resolution: Class report received that deficiency has been rectified.
The voyage data recorder system shall be subject to an annual performanace test. Master was unable to provide an annual performance test report and certificate of compliance for the newly installed voyage data recorder. SOLAS 74 (amended) V/18.8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 3 March 2020
Resolution: RCV'D REPORT THAT VDR PERFORMANCE TEST CONDUCTED.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 April 2019Resolved
A fixed deck foam fire extinguishing system shall be provided complying with the provisions of the Fire Safety Systems (FSS) Code. Master was unable to provide annual foam concentrate analysis results in accordance with MSC.1/Circ. 1312. SOLAS 74 (amended) II-2/10.8.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 3 March 2020
Resolution: RCV'D REPORT OF FOAM CONCENTRATE ANALYSIS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 December 2018Resolved
The ring, lines, and letters shall be permanently marked on the sides of the ship. The loadline is not permanently marked on the sides of the ship. ICLL 66/88 I/8, 50ac.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 8 March 2019
Resolution: Class report received. Planned completion at dry dock. See Documents.
Documentation › Manuals/Policy Documentation › Tank Vessel Loading Information
Issued 7 January 2016Resolved
The owner/operator of a forighn flag vessel may submit certification of vessels vapor control system by the classifiction society which classes the vessel that the vessel meets the requirement in paragraph (a) of this section. Vessel does not have the approved letter from class society. - 46CFR39.10-13(c)
Action required: 705 - Other - as specified
Due 6 February 2016
Resolved 11 January 2016
Resolution: Received documentation attesting to vessel's VCS approval