← All vessels
LIBERTY PRIDE
LIBERTY PRIDE is a 2009 freight ship. The Coast Guard has recorded 70 inspections since 2010, most recently in February 2026, along with 17 deficiencies, 11 operational controls and 3 casualty investigations between 2010 and 2017.
Records from 2010 to 2026. Most recent: inspection, 22 February 2026.
- Built
- 2009
- Last inspected
- 22 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2010–2017
Identity
1222356
9448114 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
KRAU
1028717
Flag
UNITED STATES
368473000 (licence lapsed)
Maury page id
psix-1028717
Inspections, by type
…with no type recorded21
Years with a record
16 calendar years (2010–2026)
The 70 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it57030 - Convention (Subpart B), Gross Ton
19535 - Convention (Subpart B), Net Ton
19535 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
KRAUMMSI 368473000 · cancelled · compulsorily equipped · granted 1 May 2019, cancelled 1 June 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 70
22 February 2026
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8313903
15 November 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8269382
1 October 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8244882
16 July 2025
Annual Inspection · MSP Select Annual Oversight
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8186517
14 June 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8159094
14 April 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8111662
11 March 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8092113
16 January 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8064792
17 September 2024
Administrative Inspection · MTSA/ISPS Verification · MSP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8003827
10 August 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7978163
24 July 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7966025
6 May 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7907472
29 April 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7903555
7 February 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7861883
12 December 2023
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7852761
30 October 2023
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7819814
23 October 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7811973
31 July 2023
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7757284
27 May 2023
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7697514
16 January 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7622122
20 December 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7611237
6 December 2022
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7604820
2 December 2022
MSP Periodic Oversight
Type not classified · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7603353
28 July 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7529940
19 July 2022
Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7516277
25 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7459127
8 May 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7446542
13 April 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7430538
11 April 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7429081
4 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7424095
11 January 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7378349
28 September 2021
Annual Inspection · MSP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7322415
10 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7309104
27 November 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7102574
12 November 2020
Annual Inspection · MSP COI Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7093816
13 August 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7043769
10 August 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7029025
13 November 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6854994
24 October 2019
MTSA/ISPS Verification · Deficiency Check · ISM SMC Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6840943
25 August 2019
MSP COI Oversight · COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6788940
26 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6763235
10 January 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6608673
25 September 2018
MTSA/ISPS Verification · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6547646
5 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6514201
6 June 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6436004
8 February 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6352034
27 December 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6329228
18 December 2017
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6346733
27 October 2017
Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6282142
4 May 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6138489
30 April 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6135450
26 March 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6108498
20 March 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6112477
26 August 2016
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5980566
25 August 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5981268
26 January 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5803355
26 January 2016
Type not recorded
No type recorded · Station Channel Islands Harbor · USCG Southwest District (CGD-SW) · Activity 5803959
7 September 2015
Annual Inspection
Physical examination · Activities Europe · Activity 5208491
23 June 2014
Internal Structural Exam · ACP Handover Survey · COI Inspection · Drydock Exam · MTSA/ISPS Verification · Hull Examination
Physical examination · Activities Europe · Activity 4871864
4 July 2012
Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Activities Europe · Activity 4321302
22 May 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4319321
28 February 2012
MTSA/ISPS Verification · DAPI Audit · Ballast Water Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4252368
28 February 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4252942
20 February 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4247806
6 September 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4137246
29 August 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4130396
21 August 2011
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4122676
11 January 2011
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3924767
13 December 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4078934
20 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3881302
Deficiency record · 17
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 September 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction for the service for which they are intended. Pressure, Thermal, and RPM Gauges throughout the vessel for are damaged and not maintained. No gauge maintenance program was able to be produced during the COI. 90 Days to implement
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 September 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that inspections are held at appropriate intervals and records of these activities are maintained. The inspections should be integrated into the ship's operational maintenance routine. Many gauges throughout the vessel were found damaged and not maintained or calibrated. SMS procedures for gauge maintenance and calibration were not implemented and tracked in the SMS. 90 Days to implement. ISM Code, 10.1,10.2,10.3, and 10.4
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 December 2022
Resolved
The machinery shall be of a design amd construction adequate for the service for which it is inteded. There was a fuel oil leak coming from the #4 cylinder fuel pump which required repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 December 2022
Resolved
The machinery shall be of a design amd construction adequate for the service for which it is inteded. There was a lube oil leak found coming from the aft oil cooler needing repair.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 6 December 2022
Resolved
The boilers shall be of a design amd construction adequate for the service for which it is inteded. The boiler cascade tank had an oil/water interface device which was in alarm mode, make necessary repairs to ensure proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 December 2022
Resolved
The boilers shall be of a design amd construction adequate for the service for which it is inteded. Make proper repairs to the boiler cascade system salinity monitor box.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 December 2022
Resolved
When the potential of the final emergency source reaches 85 to 95 percent of normal value, the emergency loads must transfer automatically to the final emergency power source and this transfer must be accomplished in no more than 45 seconds after failure of the normal source of power. MI tested emergency generator, which started on loss of power; however, air circuit breaker remained open and failed to power emergency switchboard. Engineer replaced faulty relay, MI retested as operational. Require Class verification of repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 13 April 2022
Resolved
The OCMI will determine the specific manning levels for vessels required to have certificates of inspection by part B of subtitle II of title 46 U.S.C. The masters or individuals in command of all vessels, whether required to be inspected under 46 U.S.C. 3301 or not, are responsible for properly manning vessels in accordance with the applicable laws, regulations, and international conventions.
Vessel reports sailing short the second mate required by the COI.
Vessel shall ensure second mate position is properly filled IAW the COI minimum manning requirements prior to departing the Sector Delaware Bay OCMI zone.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 August 2019
Resolved
As far as reasonable and practicable, rescue boats, other than lifeboats must be launched with their assigned crew aboard and maneuvered in the water each month. Rescue boat launching was not permitted by the port during the COI inspection. Launch and maneuver rescue boat to satisfaction of ABS surveyor. 46CFR199.180(d)(7)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 August 2019
Resolved
A fixed fire detection and fire alarm system shall be installed in machinery spaces where the installation of automatic and remote control systems and equipment has been approved in lieu of continuous manning of the space. The steering gear room's alarm horn and beacon did not activate when testing smoke detectors. 74SOLAS(09) II-2 7.4.1.2
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 August 2019
Resolved
lifesaving appliances shall be in working order and ready for immediate use. The rescue boat search light was not functional.74SOALS(14) III 20.2
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 August 2019
Resolved
Maintenance, testing and inspections of lifesaving appliances shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring reliability of such appliances. The rescue boat's brake release cable can fall off of the sheaves before tension is applied to the cable, reducing reliability. Provide manufacturer's report.74SOLAS(14) III 20.3.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2018
Resolved
Periodic Safety test procedures described in subpart 61.40 must be submitted and approved by Marine Safety Center. Current approved test procedures do not include testing for the Kongsberg alarm and monitoring system power sources. This shall be added and resubmitted to Marine Safety Center for approval.
Deck/Cargo › Cargo Stowage › General
Issued 27 October 2017
Resolved
Hazmat employees have not received recurring hazmat training within the past 3 years. A hazmat employee must receive training at least once every 3 years. Complete required training to satisfaction of marine inspector prior to carriage of hazmat. 49 cfr 172.704 (c)(2)
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 28 February 2012
Resolved
Two boat hooks from the life boat and one from the recure boat, replace.
Lifesaving › Immersion Suits › General
Issued 28 February 2012
Resolved
Provide one small immersion suit for crew member, as required to fit.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 February 2012
Resolved
Vessel failed to complete annual inspection due 4 Sep, 2011.
Casualty record · 3
13 December 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4078934
2 July 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4916313
18 December 2017Routine · role: Involved in a Marine Casualty · activity 6346733
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.