MOJO

MOJO is a 1969 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1989, most recently in May 2026, along with 54 deficiencies, 4 operational controls and 2 casualty investigations between 2002 and 2011.

Records from 1989 to 2026. Most recent: inspection, 12 May 2026.

Built
1969
Last inspected
12 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5169
102890
Flag
UNITED STATES
367036960
Maury page id
psix-102890

Inspections, by type

…with no type recorded8
Years with a record 32 calendar years (1989–2026)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)82.0 ft × 21.8 ft × 11.7 ft
Registered tonnagegross 86 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON · COSTA MESA, CA, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC5169MMSI 367036960 · active · compulsorily equipped · granted 15 March 2025, expires 26 April 2035
WCY8535MMSI not assigned · cancelled · compulsorily equipped · granted 26 January 1999, cancelled 1 February 2006
WBS2372MMSI 366740650 · expired · voluntarily equipped · granted 13 November 1997, cancelled 19 January 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

12 May 2026 Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8349648
4 February 2026 Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8270083
22 May 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8077667
31 May 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7905506
16 January 2024 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7775193
16 December 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7838188
1 June 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7668196
22 December 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7612187
21 September 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7557979
2 June 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466481
10 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7402317
5 January 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301300
20 July 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7262453
8 July 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7249995
2 June 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7213498
31 May 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7211311
19 June 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6921196
21 February 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6913129
22 January 2020 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6849961
10 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6832210
18 June 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6699446
24 April 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6371210
28 February 2018 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6360680
21 March 2017 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6104648
22 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5910656
27 January 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5796944
19 June 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4874495
15 May 2012 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4328798
11 January 2012 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4223105
23 August 2011 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4125322
9 August 2011 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4110714
5 August 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4121146
17 December 2009 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3651888
25 June 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3202010
28 April 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3194588
26 April 2008 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3194159
3 January 2008 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3122269
12 June 2007 Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2966097
18 May 2007 Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2961779
12 April 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2906586
5 April 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2898377
13 July 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2690963
25 January 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2573399
18 July 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2428006
10 May 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2063856
21 April 2004 Type not recorded
No type recorded · USCGC HADDOCK (WPB 87347) · USCG Southwest District (CGD-SW) · Activity 2135853
23 January 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1991391
10 April 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1771511
17 June 2002 Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 1632875
17 June 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1632926
17 April 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1605860
7 February 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1487020
14 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376719
25 April 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406710
27 January 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369502
15 December 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 812930
3 December 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 813326
5 May 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427660
10 February 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1420077
9 December 1998 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 809242
14 July 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396965
6 January 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 784736
4 June 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1418174
21 March 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1104122
12 March 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1103983
23 October 1996 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1159454
4 June 1996 Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380535
12 March 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 886282
10 January 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1085591
25 April 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355200
7 November 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356889
29 April 1994 Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396099
12 April 1994 Uninspected Other
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1370825
10 January 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396045
12 September 1990 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 912425
30 May 1990 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229549
27 July 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1038576
21 July 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897917
21 June 1989 Initial Certification · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1045015

Deficiency record · 54

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2022 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Inspector identified an open ground on the electrical outlet on the upper deck port side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 22 March 2022
Resolution: Operator provided objective evidence of properly grounded electrical outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 10 March 2022 Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Paddles were found permanently affixed to the life raft through the use of zip ties rather than lashed as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 22 March 2022
Resolution: Operator provided objective evidence of replaced and properly installed life float paddles.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2022 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Inspector discovered missing dead front cover for electrical distribution panel under galley stove top.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 22 March 2022
Resolution: Operator provided objective evidence of properly installed cover for distribution cover.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2022 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Inspector found two positive/hot electrical cables connected to a single breaker.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 22 March 2022
Resolution: Operator provide objective evidence of properly installed individual breakers for individual systems.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 March 2022 Resolved
Fire pump outlet must be fitted with a pressure gauge. Inspector discovered non functioning fire main pressure gauge on starboard side within engine room space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 22 March 2022
Resolution: Operator provided objective evidence of properly installed pressure guage with system providing the required pressure.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 March 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts for intended voyage. Inspector discovered charts were not up to date. Additionally, local notice to mariners were not sufficiently provided for reference by the ships master.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 22 March 2022
Resolution: Operator provided objective evidence of required charts and notice to mariners.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2021
Resolution: Vessel completed its annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The vessel experienced a loss of propulsion on the starboard main diesel engine when the propeller failed to engage. Vessel must prove proper operation of the starboard main diesel engine and propeller prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2021
Resolved 2 June 2021
Resolution: Technician installed new control head in wheelhouse and increased pressure to 65psi on hydraulic head tank. OPS tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2020 Resolved
On a vessel of more than 65 feet, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi. Found stbd fire pump only able to produce 15-20 psi.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Rectified, to the satisfaction of the attending marine inspector, prior to departure. Suction was clogged and became freed after getting underway for drills.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 June 2020 Resolved
Hydrostatic release for EPIRB was found to be expired.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Rectified, to the satisfaction of the attending marine inspector, prior to departure. Vessel replaced with a new disposable hydrostatic release unit.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 10 October 2019 Resolved
At each initial & subsequent inspection for certification, reinspection at every other inspection, the MI shall require that all observed unsafe practices or hazardous situations be corrected. Vessel is not authorized to carry passengers overnight until crew and passenger over night accomodations meet all applicable standards/regulations. 46 CFR 176.25-50.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 31 October 2019
Resolution: Vessel is authorized 6 overnight passengers at this time due to current vessel configuration.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 October 2019 Resolved
Adequate emergency lighting shall be automatically activated upon failure of the main lighting system shall be fitted along the line of escape in the vessel having lounge areas below the main deck. Vessel to install adeqaute emergency lighting. 46 CFR 184.30-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 31 October 2019
Resolution: Vessel installed adeqaute emergency lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2019 Resolved
Where liquid level indicating gauges are installed, they shall be of heat resistant material, adequately protected from mechanical damage. Vessel to install adequate protection around sight glass for f/o tank. 46 CFR 187.20-25(a)(5).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 31 October 2019
Resolution: Vessel installed adequate protection around sight glass for f/o tank.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 June 2019 Resolved
Any vessel of at least 5 net tons which engages in the fisheries on the navigable waters of the US or EEZ or Coastwise trade, unless under 67.9(c) must have a COD bearing a valid endorsement appropriate for the activity in which engaged. Provide confirmation from NVDC of submitted application for COD.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 June 2019
Resolution: vessel provided conformation from NVDC of submitted application of COD. COD was issued 19JUN19.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 June 2019 Resolved
Shut off valves installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at tank connection. The shut off valve at the tank shall be operated from outside the tank compartment. Install F/O shut off valve at tank with operation from outside the space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2019
Resolved 18 July 2019
Resolution: Vessel properly installed F/O remote shut off valves.
Operations/Management › Drills/Instruction › Fire
Issued 21 March 2017 Resolved
Create and post a station bill to outline crew duties in various emergencies
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 3 April 2017
Resolution: See Narrative.
Navigation › Piloting/Steering › Marine Charts
Issued 21 March 2017 Resolved
Provide updated charts for all areas of operation.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 3 April 2017
Resolution: See Narrative.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 March 2017 Resolved
Provide current tide tables, 2017.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 3 April 2017
Resolution: See Narrative.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 21 March 2017 Resolved
Provide proof of FCC Operator's Permit
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 11 April 2017
Resolution: See Narrative.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 March 2017 Resolved
Provide satisfactory testing service report of fixed CO2 system, report did not outline proper cylinder/agent weight and items tested.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Operations/Management › Drug and Alcohol Testing › Collection Sites
Issued 21 March 2017 Resolved
Provide updated drug and alcohol policy to include testing locations and lab locations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 March 2017 Resolved
Provide company and consortium list to prove vessel employees are subject to random drug testing.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 21 March 2017 Resolved
Provide proof that the empoyer has kept records of chemical tests as per 49CFR40.333.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 March 2017 Resolved
Provide proof that the employees undergo employee assistance program (EAP) training.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 March 2017 Resolved
Provide proof that supervisory personnel received 60 minutes or more of training on EAP.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 March 2017 Resolved
Post EAP hotline number where crew and supervsory personnel can view.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 21 March 2017 Resolved
Provide proof of a pre-employment test.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2017
Resolution: See Narrative.
Communications › Public Address System › Announcing Station
Issued 21 March 2017 Resolved
Install a public address speaker below deck, aft, so staterooms can properly hear an announcement during an emergency.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 3 April 2017
Resolution: See Narrative.
Lifesaving › Lifefloat › Painter
Issued 22 June 2016 Resolved
Discovered painter line for starboard lifefloats to not be connected to float-free link.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 June 2016
Resolution: Operator properly connected painter line to float-free link attached to the vessel.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 January 2016 Resolved
Make all through-hull valves available for inspection (through-hull valves)
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 2 February 2016
Resolution: Inspected all eight (08) through-hull valves, all sat.
Construction/Loadline › Hull › Keel
Issued 27 January 2016 Resolved
Make 03 indicated keel bolts available for inspection, from steering compartment, near floors #1, 3, & 4 from aft moving fwd.
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 2 February 2016
Resolution: All three (03) keel bolts in excellent condition, no corrosion/necking - all satisfactory.
Construction/Loadline › Penetrations › Gasket
Issued 27 January 2016 Resolved
Renew wood backing support for port main engine raw water intake, and for secured valve adjacent to port generator raw water intake valve.
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 2 February 2016
Resolution: Shipyard renewed wood backing support for both valves, all satisfactory.
Lifesaving › Lifefloat › Float-free Link
Issued 19 June 2014 Resolved
Vessel's four (04) Lifefloats were incorrectly installed. All four lifefloat painter lines were permanently secured to the deck instead of the metallic weak-link, making them unable to become float free in an emergency
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2014
Resolved 19 June 2014
Resolution: Gathered the master and four deckhands and thoroughly instructed proper installation procedures. Issue was then fixed on the spot with correct installations.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 June 2014 Resolved
Discovered the port engine exhaust piping [insulated followed by water injection towards end of piping] had a pinhole leak, causing constant water seepage from the water injection.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 25 June 2014
Resolution: Vessel representatives disassembled wet exhaust piping and performed hot work/welding to remove rusted metallic piping where leak was, and rewelded affected area. All satisfactory.
Deck/Cargo › Holds/Tanks › Coaming
Issued 19 June 2014 Resolved
Discovered vessel's single watertight door did not have a functional indicator light for opening/closure at the operating station.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 25 June 2014
Resolution: Visual signal and audible alarm are activated upon opening of watertight door.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 June 2014 Resolved
Port ring life buoy displayed wasted retroreflective tape.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 25 June 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2014 Resolved
Found eight feet of wiring in the aftermost compartment was supported overhead by plastic ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 25 June 2014
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 19 June 2014 Resolved
Vessel was unable to provide proof of drug and alcohol consortium enrollment, as well as a current employee roster indicating enrollment in consortium program
Action required: 705 - Other - as specified
Due 21 June 2014
Resolved 19 June 2014
Resolution: Vessel''s master [name withheld], provided proof of consortium enrollment and up to date emplyee list.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed proof of MIS submission.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed copy of updated consortium contract.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 9 August 2011 Resolved
Prove proper operation of the starboard main engine. Complete to the satisfaction of an attending Marine Inspector and prior to the carriage of passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2011
Resolved 23 August 2011
Resolution: Completed engine replacement. Witnessed performance test, sat.
Construction/Loadline › Hull › Side Shell
Issued 26 April 2008 Resolved
Make available for inspection the inner planks and frame in way of the 4th porthole from the stern on the starboard side. Vessel sustained limited surface damage due to a collision with a moored vessel.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 28 April 2008
Resolution: Vessel provided photo documentation of the interior. There is no damage to internal structure and the damage is only superficial. Repairs will consist of epoxy and fiberglass.
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently enrolls new employees in its contracted drug testing consortium on a quarterly basis, rather than at the time of hiring.
Due 5 July 2007
Resolved 14 June 2007
Resolution: New employee''''''''s names will be added to the company''''''''s consortium''''''''s random drug testing list prior the employee acting in a safety sensitive position.
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently is waiving random drug testing for some employees, based upon their participation in another unaffiliated company.
Due 5 July 2007
Resolved 14 June 2007
Resolution: No random drug tests will be waived in the future.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 July 2005 Resolved
Below deck lighting missing cover/guard.
Condition: Improper Installation
Due 18 July 2005
Resolved 18 July 2005
Resolution: Covered and corrected on the spot.
Electrical › Lighting (service) › Outlet Box
Issued 15 July 2005 Resolved
Outlet missing cover.
Condition: Unknown
Due 18 July 2005
Resolved 18 July 2005
Resolution: Covered and corrected on the spot.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 15 July 2005 Resolved
Fuel line on Aux Generator missing double clamp.
Condition: Unknown
Due 18 July 2005
Resolved 18 July 2005
Resolution: Double clamp added and corrected on the spot.
Engineering › Bilge Water Management System
Issued 10 May 2004 Resolved
Bilge High Water Alarm did not operate in bilge space below the crew accommodation space.
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 10 May 2004
Resolution: Alarm was rewired and is now operable.
Lifesaving
Issued 4 June 1996 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 4 July 1996
Resolved 5 June 1996
Electrical
Issued 21 June 1989 Resolved
INSTALL PROPER CIRCUIT PROTECTION IN MAIN A/C PANEL AND D/C PANEL AS PER PLAN APPROVAL LETTER DATED 14JUN89.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Engineering
Issued 21 June 1989 Resolved
PROVE PROPER OPERATION OF BILGE PIPING AND PUMP AT NEXT DRYDOCKING.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Accommodation/Occupational Safety
Issued 21 June 1989 Resolved
INSTALL PRESSURE RELIEF VALVE ON HOT WATER HEATER WITH A MAXIMUM RATING OF 100 PSI/210 DEGREE F.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Electrical
Issued 21 June 1989 Resolved
INSTALL FUSING OF PROPER AMPERAGE ON BATTERIES AS PER PLAN APPROVAL LETTER DATED 14JUN89.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Electrical
Issued 21 June 1989 Resolved
INSTALL EMERGENCY SHUTOFF SWITCH TO 12 VOLT BATTERY ON GENERATOR.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989

Casualty record · 2

17 June 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1632926
5 August 2011Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4121146
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.