Records from 2016 to 2025. Most recent: inspection, 13 November 2025.
Inspection history · 13
13 November 2025
PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8262309
12 October 2025
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8248980
9 July 2024
PSC B · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7942997
15 July 2023
PSC B · COC-TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7739638
17 January 2023
PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7616708
24 June 2022
PSC B · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7482628
8 May 2021
COC-TVE Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7185379
1 May 2020
COC-TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6945200
10 May 2019
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6680257
5 February 2019
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6632768
3 May 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6403839
4 May 2017
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6135290
5 May 2016
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5867182
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 July 2023
Resolved
Fire detection above the incinerator inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2023
Resolved 7 August 2023
Resolution: Sent class report resolving def
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 July 2023
Resolved
Stern launch lifeboat was found to have 13 containers loose, not in a waterproof container and not sealed airtight. Rations compromised.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2023
Resolved 15 July 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 June 2022
Resolved
The following protection systems shall be kept in good order... structural protection to include fire resisting divisions and protection of openings and penetrations in these devisions. PSCO noticed penetrations in fire boundaries due to new cable run leaving a 2-3 inch openings in diameter. Insulation was also removed from bulkhead in same bulkhead in engine room.
74SOLAS(20)II-2/14.2.1.1.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2022
Resolved 24 June 2022
Resolution: As an interim measure the bulkhead penetration has been sealed with an insulation. The ship was advised that permanent repairs were to be completed. Flag recommended that permanent rectification prior to completion of the upcoming dry dock in july 2023.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 June 2022
Resolved
All access openings in bulkheads of superstructure should be weather tight. CO2 room door and other doors corroded arounf knife adeg and worn gasketing as well as access hatch to engine room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2022
Resolution: Hot work is not permitted. Flag considered it acceptable to allow the vessel to continue trading. Flag State Inspection Report uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2022
Resolved
In tankers electrical equipment shall not be installed in hazardous area without meeting standards of the organization. Cable were found worn in the hazardous area in the first leayer of sheathing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2022
Resolved 24 June 2022
Resolution: Temporary repairs were completed reducing the riskto an acceptable level. Permanent reparis have been included in the upcoming Dry Dock work. Flag State Inspection Report uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2022
Resolved
Conditions after survey shall not be changed. A dehumidifier was installed as well as an improperly spliced cable run in the converter room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2022
Resolved 24 June 2022
Resolution: The unapproved cable run was terminated and the dehumidifier was connected directly to a power outlet located in the same space. Flag state inspection report uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2022
Resolved
Maintenance testing and inspection shall be carried out based on the guidelines developed by the organization. Foam analysis was not conducted annually.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 1 July 2022
Resolution: Verified vessel receifed foam analysis report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2022
Resolved
The last 1.0 meter of vapor piping must be painted red/yellow/red with red bands 0.1 meter and yellow 0.8 meter. Bands were not painted correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 1 July 2022
Resolution: Verified vapor piping was painted red/yellow/red in accordance with the CFR.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2022
Resolved
Purpose of this regulation is to present the igniton of flammable liquids. The following functional requirements shall be met: means shall be provided to control leaks of flammable liquids to control accumulation of repairs. Multiple containers of flammable dye was found on deck in a plastic container in the hazardous area. Minimum spillage was noticed in container. No MSDS in area was found by PSCO either.
Action required: 10 - Deficiency Rectified
Due 24 June 2022
Resolved 24 June 2022
Resolution: Flammable liquids were removed from the plastic container on deck and moved to the paint locker.