MAURY USCG vessel records
← All vessels

HOTTUNA

HOTTUNA is a 2009 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in March 2021, along with 17 deficiencies — 4 with no resolution recorded —.

Records from 2016 to 2021. Most recent: inspection, 2 March 2021.

Built
2009
Last inspected
2 March 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1030105
Flag
UNITED STATES
Maury page id
psix-1030105

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 5 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it1 - Simplified, Gross Ton
1 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

2 March 2021 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7149081
5 August 2019 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6774086
29 March 2019 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6656562
12 April 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6379335
5 April 2017 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6124547
28 March 2017 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6102632
10 March 2016 Hull Examination · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5830519

Deficiency record · 17

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 March 2019 No resolution recorded
Hull fracture IWO port chine @ side shell/bottom plating. Owner/Operator to grind paint for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 March 2019 No resolution recorded
Moderate pitting/wastage noted IWO starboard hull plating @ jet drive assembly (external).
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2019 No resolution recorded
Vessels main propulsion engine motor mounts were severely corroded/deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2019 No resolution recorded
Vent tube assembly for jet drive unit was found loose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Engineering › Steering Gear System › Bracket/Clamp
Issued 12 April 2018 Resolved
Attending Inspector(s) called out wasted helm pump mounting brackets.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 14 May 2018
Resolution: Attending Inspector(s) verified repairs made to main steering helm pump.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 April 2018 Resolved
Vessel failed to carry two (2) portable flashlights.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 14 May 2018
Resolution: Attending Inspector(s) verified carriage of two portable flashlights.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2018 Resolved
Vessels first aid kit contained expired items.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 14 May 2018
Resolution: Attending Inspector(s) verified contents of first aid kit.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 12 April 2018 Resolved
Vessels machinery space was not properly sealed to prevent the escape of gas/agent from pre-engineered fire suppression system.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 14 May 2018
Resolution: Attending Inspector(s) verified repairs made IWO main engine hatch/machinery space seal.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 12 April 2018 Resolved
Vessels ventilation ducts for machinery space were not equipped with closure devices to prevent the escape/release of gas/agent from pre-engineered fire extinguishing system.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 14 May 2018
Resolution: Attending Inspector(s) verified carriage/fitment of ventilation closure devices for vessel.
Construction/Loadline › Penetrations › Gasket
Issued 28 March 2017 Resolved
Renew gasket for forward engine room hatch.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified repairs made to machinery space hatch gasket.
Engineering › Fuel Oil Service System › Hose
Issued 28 March 2017 Resolved
Fuel hose between fuel return from engine to tank does not have the proper hose fittings installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified replacement of fuel hose assembly between engine and fuel tank (return).
Fire Fighting › Ventilation Systems › Ducts
Issued 28 March 2017 Resolved
Port machinery space ventilation ducting was holed, required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified replacement/installation of flexible ducting for port blower assembly, machinery space.
Fire Fighting › Ventilation Systems › Ducts
Issued 28 March 2017 Resolved
Provide ventilation closure devices for intake to machinery space (from wing)
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified carriage of ventilation closure device(s) for machinery space ventilation.
Lifesaving › Hand Flares › Quantity
Issued 28 March 2017 Resolved
Provide proper type & quantity of visual distress signals for vessels route.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified carriage of proper type/qty of visual distress signals.
Navigation › Piloting/Steering › Marine Charts
Issued 28 March 2017 Resolved
Provide current/up to date charts for areas transited.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications.
Communications › Alarms/Indicators › Fire Alarm
Issued 28 March 2017 Resolved
Troubleshoot/repair audible/visual alarm indicators for pre-engineered fire suppression system (FIREBOY).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified operation of audible/visual indicator for pre-engineered fire system.
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 March 2017 Resolved
Renew flexible hose connection between power steering pump & hydraulic actuator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 5 April 2017
Resolution: Attending Inspector verified replacement of flexible hose connection between power steering pump & hydraulic steering actuator.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.