MAURY USCG vessel records
← All vessels

OEL VARUN

OEL VARUN is a 2006 freight ship. The Coast Guard has recorded 36 inspections since 2016, most recently in August 2025, along with 17 deficiencies and 8 operational controls.

Records from 2016 to 2025. Most recent: inspection, 5 August 2025.

Built
2006
Last inspected
5 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9320001
1030446
Flag
PANAMA
Maury page id
psix-1030446

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded12
Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it25406 - Convention (Subpart B), Gross Ton
12538 - Convention (Subpart B), Net Ton
44539 - Displacement, Metric Ton
33813 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 36

5 August 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8202722
20 July 2025 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8188322
11 July 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8183232
10 July 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8182183
8 July 2025 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8179517
5 June 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8153209
20 May 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8139555
21 November 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8038136
4 November 2024 PSC B · MARPOL Annex V Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8028897
30 August 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7992655
9 August 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7979710
30 July 2024 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7970817
11 July 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7957010
2 July 2024 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7947403
13 June 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7934323
6 June 2024 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7927599
5 June 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7928937
14 May 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7915459
5 April 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7890280
20 March 2024 Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7882509
16 February 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7866755
12 February 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7864209
18 December 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7840034
1 December 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7832121
29 November 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7831075
27 November 2023 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7830005
20 November 2023 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7827304
25 September 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6274282
11 September 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6259726
11 September 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6264793
5 September 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6259595
3 October 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6015093
4 September 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5991530
24 June 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5917805
22 April 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5860354
19 February 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5818435

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 August 2025 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surroundedby at least "A-0"class divisions and be protected by self-closing doors at all levels. PSCO observed the escape trunk door in the generator room not properly latching. 74 SOLAS (20) II-2/9.2.3.4.1 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 August 2025
Resolution: Crew adjusted door to close and latch properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 August 2025 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. for the purpose, the following functional requirements shall be met: safe escape routes shall be provided. PSCOs observed an escape route door in the main switchboard room that was locked in the way of escape and requiring a key to open. 74 SOLAS (20) II-2/13.1.1 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 August 2025
Resolution: Crew unlocked door and the door is to be left unlocked.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 August 2025 Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the calceprotection cap in place. PSCO observed a pressure cylinder in the steering gear room that was missing a protective cap. 46 CFR 147.60(b)(1) Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 August 2025
Resolution: Crew added a cap to the pressure cylinder.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 20 July 2025 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. MSU SAVANNAH RECEIVED CORRESPONDENCE INDICATING THE PRESENCE OF FUEL OIL IN CARGO HOLD NO.3. PLEASE PROVIDE A REPORT FROM THE VESSEL'S CLASSIFICATION SOCIETY DETAILING THE FINDINGS, THE IDENTIFIED SOURCE OF THE LEAK, AND ANY PROPOSED PLAN FOR REPAIRS OR RECTIFICATION. 74SOLAS(20)I/11A
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2025
Resolution: RECEIVED CLASS REPORT ATTESTING TO FINDINGS, IDENTIFIED SOURCE, AND TEMPORARY FIXES MADE TO FUEL TANK.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 July 2025 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED EMERGENCY FIRE PUMP DID NOT START. WITNESSED SATISFACTORY OPERATION AFTER PROBLEM WAS IDENTIFIED. PROBLEM WAS DUE TO THE PRESENCE OF AIR IN SUCTION LINE. ONCE APPROPRIATE PRIME WAS MADE FIRE PUMP WAS FULLY OPERATIONAL. 74SOLAS(04)II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 20 July 2025
Resolution: SEE NARRATIVE
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025 Resolved
Main and emergency switchboards shall be so arranged as to give easy access as many be needed to apparatus and equipment, without danger to personnel. The sides and the rear...shall be suitably guarded. PSCO observed that the protective cover on the rear of the main switchboard were missing. 74 SOLAS (04) II-1/45.2 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 June 2025
Resolution: Received Survey Statement from DNV attesting to the approval of the arrangement for the main switchboard in the ECR being without covers but enclosed in a room behind a door with warning signs posted.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 November 2024 Resolved
Each emercgency generating set arrangedto be automatically started shall be equipped with startign devices approved by Administration with a stored energy capability of at least 3 consecutive starts. A second source of energy shall be provided for an additional 3 starts within 30 minutes unless manual starting can be demonstrated to be effective. PSCO's observed secondary source of energy not able to provide 3 starts.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2024
Resolved 21 November 2024
Resolution: Resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 June 2024 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCED SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO NOTED RESCUE BOAT THROTTLE LINKAGE OBSERVED INOPERABLE 74SOLAS(04) CH III REG.20.2
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 6 June 2024
Resolved 6 June 2024
Resolution: FIXED BEFORE USCG DEPARTED
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 June 2024 Resolved
BOUNDARIES IN SUCH A POSITION THAT THEIR FAILURE DURING A FIRE WOULD IMPEDE ESCAPE TO THE EMBARCATION DECK SHALL HAVE FIRE INTEGRITY. PSCO NOTED A-60 BOUNDARY INSULATION MISSING IN THE ESCAPE TRUNK FROM GENERATOR SPACE 74SOLAS(04) CH II-2 REG.13.3.2.4.1
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 2 July 2024
Resolution: Vessel added A boundry to escape space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 June 2024 Resolved
MAIN AND AUX MACHINERY ESSENTAIL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. PSCO NOTED BRIDGE CONTROLS FOR MAIN PROPULSION ENGINE HAS INTERMINTTENT ALARMS AND FAILURE 74SOLAS(04) CH II-1 REG. 31.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 29 August 2024
Resolution: Reviewed Class Survey Statement and all relevant correspondence correcting deficiency issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2024 Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. BWTS residual chlorine monitor is not operational. 33CFR151.2025(a)(1) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 April 2024
Resolution: Spare parts were received on board and BWTS maker's representative carried out the repairs. The TRO unit was cleaned, the inlet regulator was replaced in the TRO unit and correct set-up of parameters.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 December 2023 Resolved
Efficient guard rails shall be fitted to all exposed parts of freeboard and superstructure deck. OSCO observed broken and wasted railing along starboard side deck at midship.ICLL Reg. 25(2) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2023
Resolution: Main deck starboard side top railings in front of the following bays were cropped and renewed: bay 09 / 11 / 15 / 19 / 23 / 35 / 39 / 45
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 December 2023 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed F/O leaks from the M/E F/O supply line connection to the F/O pump. 74 SOLAS (09) II-2/4.1.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2023
Resolution: Connection gasket was change and no leaks were found on the survey.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 December 2023 Resolved
The arrangement for storage, distributions and utilization of the oil fuel shall be such to ensure the safety of the ship and persons aboard. PSCO observed oil fuel soaked lagging on the F/O supply line on the second level of the M/E and the pipes below the F/O purifiers. 74SOLAS(09)II2/4.2.2 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2023
Resolution: Bilge pump piping blanked off and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 1 December 2023 Resolved
Every steam pipe and every fitting connected there to which steam may pass shall be designed, constructed and installed as to withstand the maximum working pressure to which it may be subjected. PSCO observed a steam leak from the bilge pump pipe leasing to the incinerator.74SOLAS(04) II-1/33.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2023
Resolution: Bilge pump piping blanked off and secured.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 November 2023 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED SAFETY PINS INSTALLED ON ALL HIGH PRESSURE CO2 CYLINDERS, DEEMING THEM NON-OPERATIVE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 74 SOLAS (20) II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2023
Resolution: ALL SAFETY PINS REMOVED FROM HIGH PRESSURE CO2 CYLINDERS.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 4 September 2016 Resolved
1499 - Other - Every emergency generating set arranged to be automatically started..shall be provided with a second source of energy. Unable to start emergency generator with second set of batteries. SOLAS 74 (14) II-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2016
Resolved 4 September 2016
Resolution: Received class report attesting to proper operation and repair of emergency generator.

Ownership record