Records from 2010 to 2025. Most recent: inspection, 8 December 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
8 December 2025
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8277007
16 September 2025
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8230864
24 September 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8003512
11 October 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7806479
7 September 2023
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7786964
28 December 2022
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7612103
12 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7575823
7 December 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7363342
20 October 2021
Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7335485
23 December 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7113188
23 October 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6839344
4 September 2019
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6803729
11 December 2018
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6595951
18 December 2017
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6324573
31 October 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6296081
6 December 2016
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6044959
16 December 2015
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5772061
19 November 2015
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5766431
1 December 2011
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4198738
31 August 2011
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4127696
14 December 2010
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3907136
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 September 2019
Resolved
Accommodation space portable extinguisher missing; add extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2019
Resolution: 2A portable fire extinguisher purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2019
Resolved
Ring buoy grab line separated from buoy; replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2019
Resolution: New ring buoy purchased with grab line and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2019
Resolved
Ring buoy line not buoyant material; replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2019
Resolution: New ring buoy buoyant line purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2019
Resolved
Floating water light line not buoyant material; replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2019
Resolution: New floating water light buoyant line purchased and installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 September 2019
Resolved
Provide current chart of area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2019
Resolved 3 October 2019
Resolution: Current chart of operating area purchased and on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 September 2019
Resolved
Update first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2019
Resolved 3 October 2019
Resolution: First aid kit is updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 September 2019
Resolved
Provide portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2019
Resolution: Portable bilge pump purchased and on board.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 27 September 2019
Resolved
High water visual/audible alarm is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2019
Resolution: High water visual/audible alarm tested operable.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 December 2016
Resolved
Replace retro reflective tape on life ring.
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 16 December 2016
Resolution: Received emailed photos of renewed retro reflective tape added to subject vessel's ring buoy.
Construction/Loadline › Hull › Hull Plating
Issued 19 November 2015
Resolved
Repair both port and stbd stern corners that have been worn to glass, IAW 46 CFR 176.600.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 November 2015
Resolution: Repaired both port and starboard stern corners with resin. SAT
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 November 2015
Resolved
Replace fuel line where it mates up to copper piping aft in front of emergency shut-off. Fitting is severly corroded. IAW 46 CFR 182.455.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 November 2015
Resolution: Replaced fuel line with new fuel line. SAT
Engineering › Bilge Water Management System › Piping
Issued 19 November 2015
Resolved
Repair overboard discharge that is loose stbd side. IAW 46 CFR 182.510.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 November 2015
Resolution: Tightened overboard discharge connection. SAT
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 November 2015
Resolved
Repair or Replace propeller. IAW 46 CFR 176.600.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 November 2015
Resolution: Owner replaced propeller with new. SAT
Engineering › Fuel Oil Service System › Valve
Issued 1 December 2011
Resolved
Repair fuel shutoff valve pull cable for proper closing of the valve IAW 46CFR182.455(b)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 1 December 2011
Resolved
Provide evidence of proper servicing to fixed fire fighting system IAW 46CFR176.810(b)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 December 2011
Resolved
Re-attach buckles to straps on all type I pfds for proper donning IAW 46CFR180.71(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2011
Navigation › Piloting/Steering › Magnetic Compass
Issued 1 December 2011
Resolved
Install a magnetic compass on board with proper illumination IAW 46CFR184.402.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2011
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 December 2011
Resolved
Provide a copy of MIS report for drug testing IAW 46CFR16.
Action required: 705 - Other - as specified
Due 8 December 2011
Resolved 8 December 2011
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 1 December 2011
Resolved
Provide provisions for drug testing in case of a serious marine incident IAW 46CFR16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 December 2011
Resolved
Provide evidence of user fee payments for 2010 and 2011 IAW 46CFR2.10-101(b).
Action required: 705 - Other - as specified
Due 15 December 2011
Resolved 10 February 2012
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 February 2011
Resolved
Provide documentation of vessel's measurements from the builder to determine documentation requirements IAW 46CFR67.7. This requirement was originally issued 14DEC10 with a deadline of 28DEC10 and no resolution has been provided to our office. It shall be completed prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 28 February 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 December 2010
Resolved
Provide evidence of an active EAP IAW 46CFR16. Shall be completed prior to 28DEC10.
Action required: 705 - Other - as specified
Due 28 December 2010
Resolved 28 January 2011
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 December 2010
Resolved
Provide evidence that employees in other drug consortiums will notify Naples Bay Water Shuttle upon a failed drug test IAW 46CFR16. Shall be completed prior to 28DEC10.
Action required: 705 - Other - as specified
Due 28 December 2010
Resolved 28 January 2011
Resolution: All Captains are now members under the Company''s Drug Consortium.
Lifesaving › Hand Flares › Not on Board
Issued 14 December 2010
Resolved
Provide additional flares to equal 3 red hand and 3 orange day smoke or 6 red hand flares IAW 46CFR180.68. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 December 2010
Resolved
Replace expired battery in waterlight IAW 46CFR180.70(d). Shall be completed prior to any night trips.
Action required: 705 - Other - as specified
Resolved 15 December 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 December 2010
Resolved
Provide ammonia inhalants to first aid kit IAW 46CFR160.041. Shall be completed prior to 28DEC10.
Action required: 705 - Other - as specified
Due 28 December 2010
Resolved 13 January 2011
Fire Fighting › Fire Bucket › Capacity
Issued 14 December 2010
Resolved
Provide 3 2.5 gallon fire buckets on board IAW 46CFR181.610. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2010
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 14 December 2010
Resolved
Install closure device for engine room ventilation IAW 46CFR182.465. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 December 2010
Resolved
Provide documentation of vessel's measurements from the builder to determine documentation requirements IAW 46CFR67.7. Shall be completed prior to 28DEC10.
Action required: 705 - Other - as specified
Due 28 December 2010
Resolved 3 February 2011
Resolution: NVDC confirmed the vsl measures at 06 Net Tons and has begun the COD process.