PELAGIC EXPRESS

PELAGIC EXPRESS is a 2008 freight ship. The Coast Guard has recorded 41 inspections since 2016, most recently in December 2025, along with 39 deficiencies and 7 operational controls.

Records from 2016 to 2025. Most recent: inspection, 5 December 2025.

Built
2008
Last inspected
5 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 December 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9390381
1032554
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1032554

Documentation record

Tonnage as PSIX records it1867 - Convention (Subpart B), Gross Ton
885 - Convention (Subpart B), Net Ton
2777 - Dead Weight, Ton
3855 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 41

5 December 2025 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8277993
21 November 2025 Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8271768
5 November 2025 Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8264409
14 October 2025 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8251535
8 October 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8249284
6 October 2025 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8246882
23 September 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8239809
12 September 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8233172
22 August 2025 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8215577
16 October 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8016205
5 April 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7885728
5 April 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890414
27 September 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7797971
24 March 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7656165
20 March 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7653229
26 January 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7627859
24 December 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7612757
24 December 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7613071
17 December 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7610500
28 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7567784
7 September 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7553312
3 March 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7404571
17 February 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7442499
7 December 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7367317
1 October 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7324622
30 August 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7300449
26 August 2021 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7296409
26 February 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7146275
14 August 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7032715
4 June 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6967812
5 November 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6849881
15 October 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6835045
6 November 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6575222
14 July 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6478586
13 June 2018 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6442948
10 May 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6408134
10 May 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6142754
28 September 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6011259
19 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6004335
26 April 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5863288
29 March 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5842570

Deficiency record · 39

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 November 2025 Resolved
Where air pipes to the ballast and other tanks extend above the free board or super structured decks, the exposed parts of the pipes shall be of substantial construction. PSCO observed 3 inch hole due to corrosion on ballast tank number five port side vent and 1/4 inch hole in the port side aft freshwater tank vent. ICLL 66 Annex 1 Reg 20 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2025
Resolved 5 December 2025
Resolution: Received report from BV attesting to repairs. Sector Miami personnel conducted def check confirming repair.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 21 November 2025 Resolved
All ships of 500 gross tonnage, and upward shall… Have, a gyro-compass, heading repeater, or other means, to supply heading information visually at the emergency steering position. PSCO observed, gyro-compass, repeater, and steering gear room was unable to display heading. 74SOLAS904)V/19.2.5.2 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2025
Resolved 5 December 2025
Resolution: Received report from BV attesting to repairs. Sector Miami personnel conducted def check confirming repair.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 21 November 2025 Resolved
The machinery… Shall be of a design and construction adequate for the service for which they are intended and shall be so installed… To reduce to a minimum any danger to persons on board. PSCO observed, exhaust piping in emergency generator room was constructed in a way that allowed exhaust to re-enter the space, creating a hazardous atmosphere for persons in the space. 74SOLAS 04 II-1/26.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2025
Resolved 5 December 2025
Resolution: Received report from BV attesting to repairs. Sector Miami personnel conducted def check confirming repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 November 2025 Resolved
Where air pipes to ballast and other tanks extend above the free board or super structure decks, the exposed parts of the pipes shall be of substantial construction, satisfactory means, permanently attached, shall be provided for closing the openings of the air pipes. PSCO observed number 25 ballast air vent was missing bolts. ICLL 66 Annex 1 Reg 20 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 November 2025
Resolved 21 November 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2025 Resolved
Means of control for flammable liquids in the space shall be provided. PSCO observed open container of lube oil improperly stored in the engine room. 74SOLAS(04)II-2/5.1.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 November 2025
Resolved 21 November 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 5 November 2025 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a started energy capability of at least three consecutive starts. PSCO observed emergency generator battery set was inoperable, preventing the generator set from automatically starting. 74 SOLAS (2004) I-1/44.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2025
Resolution: Recieved Class Report from BV, and duty personnel attended vessel to confirm new batteries and charger and full functionality of the EDG starting arrangements.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2025 Resolved
The main inlet and outlet of all ventilation systems shall be capable of being closed from the outside of spaces being ventilated. PSCO observed ventillation closing fixture on upper deck for the cargo hold is missing a dog and cannot be fully closed. 74 SOLAS (2004) II-2/5.2.1.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2025
Resolved 5 December 2025
Resolution: Received report from BV attesting to repairs. Sector Miami personnel conducted def check confirming repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2025 Resolved
The main inlet and outlet of all ventilation systems shall be capable of being closed from the outside of spaces being ventilated.PSCO observed ventillation closing fixture on boat deck for the engine room with a damaged bracket, dry rotted gasket, and corroded steel which prevents the fixture from fully closing. 74 SOLAS (2004) II-2/3.2.3 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2025
Resolved 5 December 2025
Resolution: Received report from BV attesting to repairs. Sector Miami personnel conducted def check confirming repair.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 November 2025 Resolved
"A" class divisions are those divisions formed by bulkheads and decks which comply with the following criteria:... they are insulated with approved non-combustable matericals. PSCO observed incomplete installation of A 60 insulation in machinery room overhead. 74SOLAS(2004) II-2/3.2.3 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2025
Resolved 5 December 2025
Resolution: Received report from BV attesting to repairs. Sector Miami personnel conducted def check confirming repair.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 November 2025 Resolved
... the essential importance of good housekeeping in the prevention of accidents to personal, the elimination of fire hazards and the avoidance of any conditions on board likely to be injurious to seafarers health. PSCO observed unsecred deck planting and missing deck plating in the engine room, creating a harzard for the crew. ILO 147 pg 45 46 USC 70002 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 November 2025
Resolved 14 November 2025
Resolution: see Documents for CAR
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2025 Resolved
The machinery... and the fittings shall be... so installed and protected as to reduce to a minimum and danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. The design shall have regard to materials used in construction, the porpose for which the equipment is intended, the working conditions to which it will be subject and the enviromental conditions on board. PSCO observed water jacket leack from mulitple cycinders on mian engine. 74SOLAS(2004)II-1 26.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2025
Resolved 5 December 2025
Resolution: Received report from BV attesting to repairs. Sector Miami personnel conducted def check confirming repair.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 October 2025 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles... PSCOs observed a large chair in the enclosed stairway and obstacles blocking both escape routes from the engine room. 74 SOLAS (04) II-2/13.3.1.1 Code 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2025
Resolved 5 November 2025
Resolution: PSCO confirmed chair blocking escape route was moved.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 October 2025 Resolved
Ventilation openings, except those under the door, shall be fixed with a grill made of non-combustible material. PSCOs observed 03 cabin rooms missing vents on doors. 74 SOLAS (04) II-2/9.4.2.3 Code 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2025
Resolved 5 November 2025
Resolution: PSCO confirmed that ventillation openings in doors were appropriately fitted with vents.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 October 2025 Resolved
At least one means of escape required by paragraphs 3.2.1.1 and 3.2.2 shall consist of a readily accessible encolosed stairway, which shall provide coninuous fire shelter from the level of its origin to the appropriate life raft and lifeboat embarkation decks. PSCOs observed A-60 boundary missing from enclosed stairway below bridge. About 1 sq ft. 74 SOLAS (04) II-2/13.3.2.4.1 Code 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2025
Resolved 5 November 2025
Resolution: PSCO confirmed approriate placements of new A-60 insulation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 October 2025 Resolved
Openings in "A" class divisions: It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. PSCO observed self-closing "A" class door to emergency escape hatch from the engine room is unable to close. 74 SOLAS (2004) II-2/9.4.1.1.3 Code 17
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2025
Resolved 6 October 2025
Resolution: Vessel provided video evidence of door self closing completely.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2025 Resolved
The machinery...und fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed jacket water leaking out of a cover on the main engine. 74 SOLAS(2020) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2025
Resolution: PSCOs did not observe jacket water leak and temperatures were maintaining.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 September 2025 Resolved
Each muster station shall have sufficient clear deck space to accommodate all persons assigned to muster at that station. PSCO observed a large portable generator taking up the port side muster station. 74 SOLAS (2020) III/11.2
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2025
Resolved 14 September 2025
Resolution: PSCOs observed muster station cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 August 2025 Resolved
Measures shall be taken to the satisfaction of the Admin. to ensure that the equipment is functioning in a reliable manner. PSCOs observed multiple activated alarms on the engine alarm system panels in the engine room and in the emergency generator room. Additional, PSCOs observed an error on the cargo hold smoke detection system panel on the bridge. 74SOLAS(04) II-1/46 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2025
Resolution: RO submitted report of sruvey: Centralized alarm panel overhauled by OEM, connections verified, components cleaned. System thoroughly checked; confirmed fully operational.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 22 August 2025 Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. The master notified the PSCOs that the ballast water treatment system was non-operational due to a faulty sensor. 33CFR151.2025(a)(1) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 August 2025
Resolution: RO provided Report of Survey indicating Alarm caused by high engine room temperature triggering high-temp sensor. Ventilation redirected to improve cooling. BWTS found fully operational
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 August 2025 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck... escape routes shall be maintained in a safe condition, clear of obstacles. PSCOs observed mutliple escape routes blocked by spare parts and garbage. 74SOLAS(04) II-2/13.1.2 10c
Action required: 10 - Deficiency Rectified
Resolved 22 August 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 August 2025 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed spare parts and other ship's stores blocking access to fire fighting equipment including a portable fire extinguisher in the engine room and two fire equipment lockers in the steering gear room. 74SOLAS(04) II-2/14.2.1.2 10c
Action required: 10 - Deficiency Rectified
Resolved 22 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2025 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed multiple hold-back hooks preventing A-Class fire doors from closing, including doors to the BOSN storage, provisions room, and an escape truck in the engine room. 74SOLAS(04)II-2/9.1.3 10c
Action required: 10 - Deficiency Rectified
Resolved 22 August 2025
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 5 April 2024 Resolved
Four sets of full protective clothing, resistant to chemical attack, shall be provides... PSCO's observed only 02 chemical outfits onboard. 74SOLAS(04) II-2/19.3.6.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2024
Resolved 5 April 2024
Resolution: Recevied flag documentation attesting to 04 chem suits onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2023 Resolved
A fixed fire detection and fire alarm system and a sample extraton smoke detection system required in this regulation and other regulations in this part shall be of an approved type and comply with the Fire Safety Systems Code...Any required system shall be capable of continuous operation at all times. PSCO observed smoke detection for cargo space secured with multiple errors and was not operational. 74SOLAS(20)II-2/7.2.2 FSS CODE 10.2.1.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 21 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 December 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. USCG Sector Miami was notified from the Port Everglades Pilots of a loss of propulsion while mooring at berth 30, Port Everglades. 74 SOLAS (2004 Cons)CH.I/11(a). 17ac. 26DEC2022 Updated 17ac to 50ac after Class Report was accepted. Updated Form B sent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2023
Resolved 24 March 2023
Resolution: Class report attested to the satisfactory condition of main propulsion.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 7 September 2022 Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ships officers showing clearly for each deck... the various fire sections enclosed by "A" class divisions, the sections enclosed by "B" class divisions... PSCO observed ships fire control plan did not denote the graphical symbols for shipboard fire control plan as per resolution A.952(23) numbers 1.1 through 1.7. 74SOLAS(09cons..)II-2/15.2.4.1
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2022
Resolved 28 September 2022
Resolution: Received Class report from BV attesting to new fire control plans drawn in accordance with the graphic symbols in compliance with A.952(23).
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 26 August 2021 Resolved
The structure, machinery and equipment of a cargo ship as referred to in paragraph b(i) shall be subject to the surveys and inspections specified below: A minimum of two inspections of outside of the ship's bottom during any five year period...interval between two inspections shall not exceed 36 months. Vessel had documents showing completion of UWID in April 2021. RO failed to endorse the certificate. 74 SOLAS (2020) I/10(a)(v)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 August 2021
Resolution: BV provided updated SOLAS Cargo Ship Safety Construction Certificate noting the completion of outside the ship's bottom on 22APR2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 August 2021 Resolved
The machinery, boilers and other pressue vessels, associated piping systems shall be of a design and construction adequate for the service for which they are intended. PSCO observed excessive cooling water leakage on the main engine. 74SOLAS (2004 CONS) II-I/26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 3 March 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 February 2021 Resolved
The angular position of the rudder shall: if the main steering gear is power-operated, be indicated on the navigation bridge...PSCO's could not verify true position of the rudder due to 05 degree difference between the bridge and local indicator. 74 SOLAS (04) II-1/29.11.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 28 April 2021
Resolution: Rudder angle indicator repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2020 Resolved
A fixed-gas extinguishing system complying with the provisions of the Fire Safety Systems Code; Two separate controls shall be provided for releasing carbon dioxide into a protected space and to ensure activation of the alarm. Vessel reported to Captain of the Port Sector Miami that the fixed-CO2 system for their engine room is not currently capable of remote activation, but is capable of local activation. II-2 /4.1.1.1 FSS Code 5.2.2.2.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2020
Resolved 27 August 2020
Resolution: A flexible hose, rated at 3200 PSI was installed. Both new pilot lines were pressure tested at 120 BAR, system is fully functional and operational both remotely and locally.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 6 November 2019 Resolved
Every Ship 100 gross tons shall carry a garbage management plan which the crew shall follow. Crew is not following vessel garbage plan for cooking oil, operational waste, or E-Waste. MARPOL Annex V Reg 10.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019
Resolved 25 November 2019
Resolution: Flag attestation submitted showing familiarization training conducted.
Communications › Alarms/Indicators › Fire Alarm
Issued 14 May 2018 Resolved
Detection System shall initiate audible and visual alarms in sufficient places to ensure that the alarms are heard and observed on the navigation bridge and by a responsible engineering officer. The fire alarm system in the machinery space did not give an audible alarm. 74 SOLAS (2004) II-2/7.4.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 13 June 2018
Resolution: Fire Alarms now provide audible and visual notification in the machinery space.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 May 2018 Resolved
Rudder angle indicator to determine and display rudder angle readable from conning position. Rudder angle indicator from remote steering was up to 10 degrees variance from local steering indicator. 74 SOLAS (2014) V/19.2.5.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2018
Resolution: As per class report, technician resolved the issue of the rudder angle indicator being out of calibration.
Communications › Alarms/Indicators › Fire Alarm
Issued 10 May 2018 Resolved
Detection System shall initiate audible and visual alarms in sufficient places to ensure that the alarms are heard and observed on the navigation bridge and by a responsible engineering officer. The fire alarm system in the machinery space did not give an audible alarm. 74 SOLAS (2004) II-2/7.4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2018
Resolution: Flag issued conditional CSSE valid until 11JUN18 pending permanant rectification of the issue with conditions. See survey.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 10 May 2018 Resolved
Vessel must submit the ballast water report no later than 6 hours after arrival at the port or place of destination. Vessel did not submit ballast water report within the alloted time.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 May 2018
Resolution: Vessel submitted ballast water report before Coast Guard team departed vessel and were educated on the requirement to submit a ballast water reporting form when entering each COTP zone.
Fire Fighting › Means of Escape › Doorways
Issued 28 September 2016 Resolved
Fire doors in main vertical zone bulkheads, the doors shall be self closing and be capable of closing with an angle of inclination of up to 3.5 opposing closure. Engine room emergency escape self closing firedoor is not self-closing. 74SOLAS(09Cons.) Ch.II-2/Reg.9.4.1.1.4.1 Def rectified on the spot.
Action required: 705 - Other - as specified
Resolved 28 September 2016
Resolution: Deficiency was rectified to the satisfcation of the CG before departing the vessel.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 21 September 2016 Resolved
1510 - Navigation Equipment - Steering gear control shall be provided for the main steering gear on the navigation bridge. The vessel's controllable pitch propeller bridge automation controls are not operational. 74 SOLAS (04 cons) CH II-1/Reg 29.7.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2016
Resolution: Class survey report stated four damaged communication cables were renewed which communicated commands from the wheelhouse controls to the CPP mechanism in the engine room. After testing, all systems functioned properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 April 2016 Resolved
1400 - Automatic control of the CPP monitoring and control system found inoperable from the bridge. 74SOLAS(14) CH.I/Reg. 11(a)
Action required: 705 - Other - as specified
Resolved 31 May 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 29 March 2016 Resolved
0750-Fire Prevention-Category A Machinery Spaces containing internal combustion machinery shall be provided with a fixed fire-extinguishing system.Fixed CO2 system discharge nozzles can't be located in engine room which is a machinery space of category A.Operating procedures & fire control plan state that a fixed CO2 suppression system is installed in engine room.SOLAS74(04)ChII-2/Reg10.5.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2016
Resolution: Received class report stating that a shore based specialized service company was contracted to carry out general check of CO2 piping in engine room & blow all lines.All nozzles located and found in order.Location of the nozzles marked above floor plates.

Ownership record