MAURY USCG vessel records Sign in
← All vessels

DEVELOPMENT DRILLER III

DEVELOPMENT DRILLER III is a mobile offshore drilling unit. The Coast Guard has recorded 7 inspections since 2009, most recently in July 2016, along with 5 deficiencies.

Records from 2009 to 2016. Most recent: inspection, 18 July 2016.

Built
Not recorded
Last inspected
18 July 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8769121 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1034275
Flag
VANUATU
—
Maury page id
psix-1034275

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (2009–2016)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it37981 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

18 July 2016 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5949258
3 August 2015 COC-MODU Renew
Type not classified · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5162034
22 June 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4897085
9 July 2012 COC-MODU Annual · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4373665
3 July 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4367900
10 August 2011 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4208326
18 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3727513

Deficiency record · 5

Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 August 2015 Resolved
Adequate provisions should be made to facilitate cleaning, inspection and maintenance of machinery. Multiple jacket water and lube oil leaks were present in both engine rooms and valve WC-PT-1001 in thruster room #1 (discharge pressure central fresh water cooling P-41) was corroded.
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 3 August 2015
Resolution: Received email from Captain with accompanying power point showing that deficiency had been corrected.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 3 August 2015 Resolved
In addition to complying with the specifics provisions for fire integrity of bulkheads and decks in this section and in 9.2 the minimum fire integrity of bulkheads and decks should be as prescribed in Tables 9-1 and 9.2. Sections of insulation have been removed in both engine rooms and at CO2 station.
Action required: 705 - Other - as specified
Due 3 September 2015
Resolved 3 August 2015
Resolution: Received email from Captain with accompanying power point showing that deficiency had been corrected.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 9 July 2012 Resolved
A-60 bulkhead within the cement room was torn and hanging off the bulkhead beside the deck enterance and approx 18" from the deck up. This insulation needs to be repaired with approved insulation and faseners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2012
Resolved 30 November 2012
Resolution: Received documentation from [name withheld] that ABS has cleared installation of the new insulation. Scanned in ABS Survey Report.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 10 August 2011 Resolved
PRIOR TO ANY WELL OPERATION - Launch, operate propulsion, steering and sprinkler systems in water, and recover all 4 life boats.
Action required: 705 - Other - as specified
Resolved 12 August 2011
Resolution: All 4 life boats were lowered, operated in water and recovered per OIM statement.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 December 2009 Resolved
Vessel reported unexpected discharge of the Novec firefighting syst
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 3 March 2010
Resolution: Recieved report from Master that ABS has cleared the NOVEC Fire Supression System.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.