MAURY USCG vessel records
← All vessels

KATHRINE KOSAN

KATHRINE KOSAN is a 2008 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in May 2026, along with 2 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 24 May 2026.

Built
2008
Last inspected
24 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2026
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9366940
9V7450
1034375
Flag
ISLE OF MAN
Maury page id
psix-1034375

Documentation record

Tonnage as PSIX records it9735 - Convention (Subpart B), Gross Ton
2920 - Convention (Subpart B), Net Ton
9325 - Dead Weight, Metric Ton
15377 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

4 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

24 May 2026 COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8379409
16 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6242924
6 August 2017 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6229245
21 June 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5907118

Deficiency record · 2

Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 6 August 2017 Resolved
1138-Liquified Gasses in Bulk-Pressure relief valves should be set and sealed by a competant authority and a record of this action, including values of set pressure, should be retained aboard the ship. Vessel could not produce the record of service for safety relief valves. 74SOLAS(14), VII/13.1, IGC(93)8.2.5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 16 August 2017
Resolution: SEC HOU-GAL PSC Branch received proper documentation satisfying the requirement.
Construction/Loadline › Structures › Door
Issued 6 August 2017 Resolved
1850-Fire Protection-Cargo deck area airlockdoors should be self closing and without any holdback arrangements. Vessel's airlock was missing a self closing unit on the exterior door. 74SOLAS(14)VII/13.1, IGC(93)3.6.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 2 June 2026
Resolution: Verified in working order by CG Sec Hou-Gal during COC-REN exam