MAURY USCG vessel records
← All vessels

ALPINE PERSEFONE

ALPINE PERSEFONE is a 2008 tank ship. The Coast Guard has recorded 2 inspections in 2019, along with 2 deficiencies.

Records in 2019. Most recent: inspection, 20 March 2019.

Built
2008
Last inspected
20 March 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 March 2019
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9379961
1034494
Flag
LIBERIA
Maury page id
psix-1034494

Documentation record

Tonnage as PSIX records it41696 - Convention (Subpart B), Gross Ton
21778 - Convention (Subpart B), Net Ton
69999 - Dead Weight, Ton
83951 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

20 March 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645782
22 January 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6613065

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 January 2019 Resolved
Where "A" class divisions are penetrated, such penetrations shall be suitably insulated by extension of the insulation at the same level of the division. During cargo pump room examination observed electrical wires penetrating through the bulkhead missing insulation as required per the appropriate fire boundary. Ship's force replaced insulation. 74SOLAS(04) CH. II-2, Reg.9.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 January 2019
Resolved 22 January 2019
Resolution: Ship's force replaced missing insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2019 Resolved
The machinery, boilers, and other pressure vessels, associated piping sysems and fittings shall be of a design and construction adequate for the service for which ther are intended and shall be so installed and protected as tu reduce to a minimum any dangerto persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. Hydraulic power pack in Bosn locker has a hydraulic leak. 74SOLAS(04) Ch. II-1, Reg 26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 January 2019
Resolved 20 March 2019
Resolution: DNV-GL attended vessel and attested to repairs. Provided class report and uploaded into ships documents.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.