Construction/Loadline
Issued 25 June 2002
No resolution recorded
Complete regulatory dry dock examination to the satisfaction of Flag or Classification Society prior to operating in U.S. Waters after 30 November 2002.
Due 30 November 2002 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 29 May 2002
No resolution recorded
Provide valid CCSSC certificate
Action required: 17 - Rectify deficiencies prior to departure
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 29 May 2002
No resolution recorded
Provide Safe Manning Certicicate
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Steering Gear System › Ram
Issued 29 May 2002
No resolution recorded
Repair leaking steering gear ram on aft deck
Action required: 17 - Rectify deficiencies prior to departure
Construction/Loadline › Structures › Door
Issued 29 May 2002
No resolution recorded
Make all watertight doors and hatches operational and watertight
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 May 2002
No resolution recorded
Provide ladder for engine room emergency excape.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 May 2002
No resolution recorded
remove and dispose properly, leaking cans of paint in forepeak. Remove all paint unless unless fire protected
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 29 May 2002
No resolution recorded
provide adequate anchoring arrangments for tug.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Construction/Loadline › Structures › Superstructure
Issued 29 May 2002
No resolution recorded
repair damaged pilot house on main deck, behind galley Stove.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Compressed Air System (control) › Compressor
Issued 29 May 2002
No resolution recorded
Pepair secondary air compressor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Engineering
Issued 29 May 2002
No resolution recorded
Provide flag state acceptance of missing generator
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Electrical
Issued 29 May 2002
No resolution recorded
repair remaining generators junction box and provide covers foe armature.
Action required: 17 - Rectify deficiencies prior to departure
Electrical
Issued 29 May 2002
No resolution recorded
provide covers for all exposed lighting throughout the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Fixed Fire Detection System
Issued 29 May 2002
No resolution recorded
provide fixed fire suppression and decetion system for engine room.
Action required: 17 - Rectify deficiencies prior to departure
Engineering
Issued 29 May 2002
No resolution recorded
Provive adiquate source of emergency power
Action required: 17 - Rectify deficiencies prior to departure
Navigation › Piloting/Steering › Marine Charts
Issued 29 May 2002
No resolution recorded
provide required nautical charts and publications
Action required: 17 - Rectify deficiencies prior to departure
Navigation › Piloting/Steering › Compass Deviation Table
Issued 29 May 2002
No resolution recorded
provide compass deviation table
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Navigation › Piloting/Steering
Issued 29 May 2002
No resolution recorded
Provide day time signal lamp
Action required: 17 - Rectify deficiencies prior to departure
Communications › Radio Communications › EPIRB
Issued 29 May 2002
No resolution recorded
provide 406 CAT 1 EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 29 May 2002
No resolution recorded
provide working lights on all PFDs
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 May 2002
No resolution recorded
properly mount fire extinguisher on bridge
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Fire Hydrants › Condition
Issued 29 May 2002
No resolution recorded
properly equip both firestations on main deck. (hose ,nozzle, spanner wrench)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting
Issued 29 May 2002
No resolution recorded
Provide fire ax
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 29 May 2002
No resolution recorded
Provide adequate liferaft with weak link and hydrostatic release
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure