Inspection history · 24
27 October 2025
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8259518
23 July 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7965122
13 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7668172
21 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7435555
12 May 2021
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7195503
10 December 2019
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6871870
13 December 2017
Administration
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6326464
9 November 2017
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6307427
4 August 2017
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6265698
12 July 2017
Administration
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6207517
23 March 2015
Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5088848
29 August 2012
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4425377
13 February 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4243585
7 March 2011
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3959052
10 March 2010
Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3694204
3 September 2008
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3317790
5 June 2007
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2952737
25 September 2000
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 282607
11 July 2000
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 279906
28 January 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 425160
12 September 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 407964
12 September 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 407966
11 August 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 407331
1 May 1992
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 9031
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 October 2025
No resolution recorded
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. The COI for the vessel has expired as of 27MAY2025. omplete renewal inspection prior to engaging in or intending to engage in the service of pulling, pushing, or hauling alongside, or any combination of pulling, pushing, or hauling alongside. 46 CFR 136.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 October 2025
No resolution recorded
A vessel that is exposed to salt water not more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least once every 5 years. The vessel has not undergone the required dry dock inspection which was due 31JAN2025. 46 CFR 137.300(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 July 2024
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Bilge in engine room had excess oil accumulation. Remove oily waste.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 8 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2023
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Pressure vessel relief valves must be tested twice every 5 years, with no more than 3 years elapsing since last test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 9 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 May 2021
Resolved
Prove proper operation of port main engine prior to getting underway or any operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: MI attended vessel, got underway and verified proper operation of both MDEs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 May 2021
Resolved
Prove proper operation of the gauges on the bridge for port generator prior to getting underway or any operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: MI attended the vessel and verified all gauges in PH.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 May 2021
Resolved
Complete satisfactory COI inspection prior to vessel getting underway or any operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: MI attended vessel and completed COI inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2021
Resolved
Provide metal cable supports for electrical wires over egress routes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 21 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 12 May 2021
Resolved
Post signs on both sides of each escape hatch and emergency exit with two inch letters, "EMERGENCY EXIT, KEEP CLEAR"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 21 September 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 May 2021
Resolved
Upon the start of vessel operations or movement, complete and submit, two weeks of logs in accordance with 46 CFR 140.915, specifically the navigation assessment required by 46 CFR 140.635.
Action required: 705 - Other - as specified
Resolved 21 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2020
Resolved
Bench test or replace relief valve on pressure vessel and prove proper operation at set relief pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 6 February 2020
Resolution: Relief valve was replaced and a CG Inspector observed proper operation at set relief pressure.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 January 2020
Resolved
Install adequate guard on rotating machinery on port MDE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 6 February 2020
Resolution: An adaquate guard was installed on rotating machinery on Port MDE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 January 2020
Resolved
Prove starboard life buoy and attached line meets requirements in 46 CFR 160.050.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 6 February 2020
Resolution: CG Inpectors observed that the grab line on the starboard life buoy had been replaced and met the requirements set in 46 CFR 160.050.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 27 January 2020
Resolved
Provide adequate fall overboard protection along length of vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 6 February 2020
Resolution: Steel cable was installed as adequate fall overboard protection system along the length of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 27 January 2020
Resolved
Mark voids and other confined spaces to mitigate health and safety hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 6 February 2020
Resolution: Voids and confined spaces were properly marked so as to be easily identifiable.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 27 January 2020
Resolved
Provide screen on potable water tank vent to mitigate health and safety hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 6 February 2020
Resolution: Screen was added to potable water tank vent.
Documentation
Issued 25 September 2000
Resolved
CG Local Notice to Mariners and USACE Notice to Navigation must be onboard
Condition: Unknown
Due 25 September 2000
Resolved 27 September 2000
Lifesaving
Issued 25 September 2000
Resolved
All broken glass in windows must be removed and or replaced
Condition: Unknown
Due 25 September 2000
Resolved 27 September 2000
Lifesaving
Issued 25 September 2000
Resolved
Replace USCG approved life rings
Condition: Unknown
Due 25 September 2000
Resolved 27 September 2000
Electrical
Issued 25 September 2000
Resolved
All lights must have proper protective coverings
Condition: Unknown
Due 25 September 2000
Resolved 27 September 2000
Lifesaving › Lifebuoys › Serviceable
Issued 11 July 2000
Resolved
Life rings need to be replaced and available when needed.
Condition: Unknown
Due 11 August 2000
Resolved 11 July 2000
Electrical
Issued 11 July 2000
Resolved
All lighting fixtures need protective coverings
Condition: Unknown
Due 11 August 2000
Resolved 13 July 2000
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 January 1999
Resolved
FIRE EXSTINGUISHERS WERE ON THE DECK, THEY NEEDED TO BE MOUNTED TO THE BULKHEAD.
Condition: Unknown
Due 28 February 1999
Resolved 28 January 1999
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 28 January 1999
Resolved
OIL POLLUTION PREVENTION PLACARD WAS MISSING. NEEDS TO BE REPLACED IN A VISABLE AREA IN THE ENGINE ROOM.
Condition: Unknown
Due 28 February 1999
Resolved 28 January 1999
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 28 January 1999
Resolved
INSULATION IS MISSING AROUND EXHUAST.
Condition: Unknown
Due 28 February 1999
Resolved 28 January 1999
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 28 January 1999
Resolved
SIGHT TUBES NEED TO BE GLASS INSTEAD OF PLASTIC.
Condition: Unknown
Due 28 February 1999
Resolved 28 January 1999
Navigation
Issued 11 August 1997
Resolved
VESSEL WAS MISSING LOCAL NOTICE TO MARINERS.
Condition: Unknown
Due 16 September 1997
Resolved 16 September 1997
Accommodation/Occupational Safety
Issued 11 August 1997
Resolved
VESSEL'S MSD VENT WAS DISCONNECTED.
Condition: Unknown
Due 16 September 1997
Resolved 16 September 1997