← All vessels
NAVIGATOR SCORPIO
NAVIGATOR SCORPIO is a 2009 tank ship. The Coast Guard has recorded 10 inspections since 2009, most recently in January 2026, along with 4 deficiencies and 3 operational controls.
Records from 2009 to 2026. Most recent: inspection, 20 January 2026.
- Built
- 2009
- Last inspected
- 20 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9404792 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5DP6
1035809
Flag
LIBERIA
—
Maury page id
psix-1035809
Inspections, by type
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it18311 - Convention (Subpart B), Gross Ton
5493 - Convention (Subpart B), Net Ton
23330 - Dead Weight, Ton
33301 - Displacement, Ton
5493 - Convention (Subpart B), Net Ton
23330 - Dead Weight, Ton
33301 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
20 January 2026
COC-GAS Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8298747
9 December 2021
PSC B · COC-GAS Annual · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7365152
24 November 2020
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7101181
28 October 2020
COC-GAS Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7085195
27 October 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7084853
18 April 2019
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6662676
13 July 2015
COC-GAS Renew · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5182790
22 March 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4820958
5 January 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3657039
10 December 2009
Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3648144
Deficiency record · 4
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 9 December 2021
Resolved
A gas carrrier shall comply with the requirements of the International Gas Carrier Code...The equipment shoul be capable of producing inert gas with an oxygen content at no time greater than 5% by volume subject to the special requirements of chapter 17. Vessel's inert gas generator is unable to produce inert gas. 74SOLAS(2020) VII/13.1, IGC Code 9.5.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 October 2020
Resolved
Air lock doors are to be self-closing. The outer air lock door closing mechanism was inoperable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2020
Resolved
Pilot ladder was rigged with shackles holding ladder at the step, which is not a point as strong as the side ropes. The platform at the bottom of the accommodation ladder not level as rigged. This is not a compliant arrangement as per SOLAS V/23 and Resolution A 1045(27).
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 April 2019
Resolved
On ships carrying flammable or Toxic products a water spray system for cooling, fire prevention and crew protection should be installed to cover cargo tank domes and cargo manifolds. Deck water spray did not provide adequate coverage over tank dome #2 Starboard or either port or starboard manifolds.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.