MAURY USCG vessel records Sign in
← All vessels

F3

F3 is a 2010 tank barge. The Coast Guard has recorded 18 inspections since 2010, most recently in June 2026, along with 9 deficiencies.

Records from 2010 to 2026. Most recent: inspection, 11 June 2026.

Built
2010
Last inspected
11 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1036158
Flag
UNITED STATES
—
Maury page id
psix-1036158

Inspections, by type

Years with a record 17 calendar years (2010–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)125.0 ft × 32.0 ft × 9.3 ft
Registered tonnagegross 312 / net 312
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNATIONAL MAINTENANCE & REPAIR INC · HARTFORD, IL, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 15 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it312 - Simplified, Gross Ton
312 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

11 June 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8383776
23 May 2025 MTSA Verification · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8139756
21 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7909515
12 June 2023 Administrative Inspection · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7709609
14 June 2022 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7472075
9 June 2021 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7220823
20 May 2020 Administrative Inspection · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6956610
16 October 2019 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6836082
28 November 2018 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6813285
14 November 2017 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6376888
2 November 2016 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6058654
17 September 2015 Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5722734
21 October 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5010071
18 December 2013 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4771403
5 November 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4490588
21 October 2011 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4166463
16 November 2010 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3892359
30 March 2010 Initial Certification · Administrative Inspection · Initial Construction-Excluding Oversight · Internal Structural Exam · Plan Review (Other than "T") · Construction Oversight · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3702774

Deficiency record · 9

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 14 June 2022 Resolved
No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel or facility operator, as appropriate, tests and inspects the equipment in accordance with paragraphs (b), (c) and (f) of this section and the equipment is in the condition specified in paragraph (c) of this section... (c) For the purpose of paragraph (a) of this section:... (2) Each transfer system relief valve must open at or below the pressure at which it is set to open; (This site also contains pipe testing requirements). Relief valves on fuel oil transfer system and slop oil transfer system not tested within the last year. Cargo pumps on systems with non-tested relief vessels prohibited from use until properly tested and documented in accordance with 33 CFR 155.820.
Action required: 705 - Other - as specified
Resolved 20 June 2022
Resolution: Relief valves properly tested by company representative.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 June 2022 Resolved
The vessel operator shall keep a written record available for inspection by the COTP or OCMI of... (b) the date and result of the most recent test and inspection of each item tested or inspected as required by 33 CFR 156.170. 33 CFR 156.70(c)(3) includes each transfer pipe system...must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. Record of piping test conducted on 31 Mar 2022 not available during inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 20 June 2022
Resolution: Testing of cargo transfer system relief valves properly documented.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 June 2022 Resolved
Hose used to transfer oil or hazardous material must meet the requirements of § 154.500 of this chapter. 33 CFR 154.500 states each hose must be marked with maximum allowable working pressure and NOT pressure used for the test required by 33 CFR 156.170. Three 1 1/4 inch cargo transfer hoses were marked with test pressure and not maximum allowable working pressure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 15 June 2022
Resolution: Cargo transfer hoses re-marked with proper MAWP.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 27 September 2010 Resolved
Ground fault detector not installed on vessel generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Resolution: Ground fault detector instalalled in vessel generator room.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 September 2010 Resolved
No non-conductive mat on metal deck at switch board in generator room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Resolution: Non-conductive mat installed on metal deck at switch board in generator room.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 27 September 2010 Resolved
Only 2 portable fire extingusihers (B-II) installed on vessel, 3 are required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Resolution: Third portable fire extinguisher (B-II) installed on vessel.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 27 September 2010 Resolved
Provide copy of tests for emergency shut down & cargo transfer hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2010
Resolution: Owner/Operator provided documenation showing emergency shut down properly operated. Cargo hoses to be purchased new and placed in service. There are currently no hoses on board the vessel.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 27 September 2010 Resolved
Provide a copy of Oil Transfer Procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2010
Resolution: Reviewed OTPs which were in substantial compliance with regs.
Documentation › Markings/Placards › Warning Signs
Issued 27 September 2010 Resolved
Diesel fuel tank for vessel service generator was not properly marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Resolution: Diesel fuel tank for vessel service generator was properly marked.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.