MAURY USCG vessel records
← All vessels

BLACK BEARD

Built
1970
Last inspected
3 June 2021
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 June 2021
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9235
103633
Flag
UNITED STATES
Maury page id
psix-103633

Documentation record

Registered dimensions (L × B × D)35.3 ft × 13.0 ft × 5.7 ft
Registered tonnagegross 15 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCOTTIE CRAFT BOAT CORP · N MIAMI BEACH, FL, UNITED STATES · built 1970
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPONCE, PR
Endorsements, as the file codes themcw_un
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 8 inspections, each with its date, unit and type; 29 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

3 June 2021 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7214849
15 October 2019 Deficiency Check · Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6876572
22 January 2019 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6613435
27 July 2018 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6495245
28 April 2017 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6134035
4 April 2017 Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6118757
31 March 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6115119
25 April 2016 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5862376

Deficiency record · 29

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 December 2019 Resolved
Battery on EPIRB expired. Vessel is limited to voyages no further than 3 miles from shore until replacement is verified onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 January 2020
Resolution: Replaced EPIRB and battery
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 December 2019 Resolved
Battery in light float for ring buoy was of the incorrect type and style.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 January 2020
Resolution: Rplaced with appropriate battery type
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 December 2019 Resolved
Could not get underway to conduct drills due to dead batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 January 2020
Resolution: Drills conducted satisfactorily
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 July 2018 Resolved
Required fixed fire extinguishing system missing from machinery space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Fireboy system is installed and certified. Verified proper operation of manual override and engine shutdown.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2018 Resolved
Portable fire extinguishers required by COI were not aboard vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: All required fire extinguishers were on board and appropriately serviced and mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 July 2018 Resolved
Two of the three installed bilge pumps were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: All bilge pumps were verified as properly installed and working.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 July 2018 Resolved
All high water alarms were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: All high water alarms were verified as properly installed and working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2018 Resolved
Provide written documentation to the Coast Guard that both installed alternators on main propulsion engines are approved and suitable for marine use and application on installed engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Newly installed alternators were of approved for marine service type.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2018 Resolved
Dead-end wiring observed through out vessel. Directed vessel rep to remove all dead end wiring.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Wiring in machinery space, accomodation and operating station was verified as correct and no visible dead end wiring was found.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2018 Resolved
Electrical fuse cabinet is not watertight and some electrical wiring spliced with battery conductors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Fuse cabinet is appropriate and installed correctly for use
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2018 Resolved
Installed electrical lighting observed inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 July 2018 Resolved
Anchor light lens missing. Prove prper operation of all navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: All navigation lights were verified as operable and of an approved type.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 July 2018 Resolved
Batteries in machinery space are uncovered.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Custom made battery box top was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 July 2018 Resolved
Batteries in machinery space are unsecured.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Batteries are secured in box using a brace from the forward end of the box.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 27 July 2018 Resolved
No proof of monthly EPIRB testing was available.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: COI was surrendered. Monthly testing resumes as of date of COI.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 27 July 2018 Resolved
Hydrostatic release for EPIRB expired in April, 2018.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: new hydro-static release was purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 July 2018 Resolved
Vessel name was partially worn off of life buoy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Vessel name clearly marked on ring bouy.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 July 2018 Resolved
Abandoned ship and man overboard drill records were not available to Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Drill records show history before COI surrender and resume as of date of COI.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 July 2018 Resolved
Record of fire drills were not available to Coast Guard inspectors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Records show history of drills before COI surrender and resume as of date of new COI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 July 2018 Resolved
FCC Safety Radiotelephony Certficate expired on 01Mar17.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Verified new radio certificate.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 July 2018 Resolved
Aft deck rails broken / missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Repaired appropriately.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 July 2018 Resolved
Rotted deck on the port side of forward cabin. Vessel owner to provide written repair plan for approval by Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2019
Resolution: Repair plan was submitted and verified.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 28 April 2016 Resolved
Install Engine ventilation vent closures
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2016
Resolution: Satisfactory Installation of new vent closures.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 28 April 2016 Resolved
Install Pre-Engineered fixed fire system of large enough capacity IAW 46 CFR 181. 410 (f)(4)(i).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2016
Resolution: Vessel installed new Pre-Engineered fixed fire systems approved for space.
Lifesaving › Lifebuoys › Approval
Issued 28 April 2016 Resolved
Replace life ring
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2016
Resolution: Vessel installed approved life ring.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 April 2016 Resolved
Replace life ring float light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2016
Resolution: life ring float light repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 April 2016 Resolved
Install mechanical fastener on battery terminals
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2016
Resolution: mechanical fastener on battery terminals installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 April 2016 Resolved
Mark fuel shut off valve location
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2016
Resolution: fuel shut off valve location marked.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 April 2016 Resolved
Install missing deck railings located starboard side aft
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2016
Resolution: Installed missing deck railings.