SM PORTLAND is a 2008 freight ship. The Coast Guard has recorded 17 inspections since 2021, most recently in August 2026, along with 10 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 2021 to 2026. Most recent: inspection, 7 August 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it51313 - Dead Weight, Metric Ton 67515 - Displacement, Metric Ton 40839 - Convention (Subpart B), Gross Ton 24099 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 August 2026No resolution recorded
A lifejacet complying with the requirements of the code shall be provided... A lifejacket shall be provided with a reasonable buoyant line or other means to secure it to another person
PSCO observed lifejackets on board the vessel were not fitted with means of securing one lifejacket to another via a buoyant line as required by LSA
74SOLAS III/7.2.1
LSA 2.2.1.16
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2026
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 March 2025Resolved
ESCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. EMMERGENCY ESCAPED HATCH FROM ENGINE ROOM TO MAIN DECK WAS BLOCKED BY BENT CARGO LASHING BRACKET AND SAFETY ROPE.
74 SOLAS 2009 ED II-2/13.1.2
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2025
Resolved 22 March 2025
Resolution: CREW CLEARED OBSTACLES BY BENDING BRACKET BACK INTO PLACE AND LOOSEN ROPE.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 22 March 2025Resolved
THE MACHINERY... SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSON ON BOARD, DUE REGARD BEIGN PAID TO MOVIN G PARTS. NUMBER 1 JACKET WATER PUMP TO MAIN ENGINE WAS MISSING SAFE GUARD TO MOVING SHAFT.
74 SOLAS 2009 ED II-1/26.1
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2025
Resolved 22 March 2025
Resolution: CREW REPLACED MISSING GUARD
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2025Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT, E.G. IN PAINT LOCKERS... UNLESS THE ADMINISTRATION IS SATISFIED THAT SUCH EQUIPMENT IS... OF A TYPE WHICH WILL NOT IGNITE THE MISTURE OCNCERNED. EXPLOSION- PROOF LIGHT IN PAINT LOCKER WAS NOT PROPERLY TIGHTENED AND ABLE TO IGNITE FLAMMABLE GASES.
74 SOLAS 2009 ED. II-1/45.10.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2025
Resolved 22 March 2025
Resolution: CREW TIGHTENED COVER TO EXPLOSION-PROOF LIGHT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 August 2022Resolved
Ships shall be designed, constructed and maintained in compliance with the electrical requirement of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI-1/1. PSCO observed open electrical panel for W2 anchor winch with temporary fan for cooling electrical installations.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 December 2022
Resolved 5 October 2022
Resolution: Received class report attesting to repairs made to W2 windless electrical panel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 November 2021Resolved
07126- N/A (Oil accumulation in engine room)- The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed oil pooling in "hot box" area of MDGE 1, 2, 3 & 4.
PSCO also observed oil aturation on electrical wiring on MDGE 1, 2, 3 & 4. 74 SOLAS(09) II-2/4.1.1- 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 9 November 2021Resolved
07122- N/A (Fire Control Plan)- The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed oil-soaked lagging on ME FO drain line, ME LO line, ME inlet piping & ME purifier line. 74 SOLAS(09) II-2/4.1.1- 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 November 2021Resolved
07126- N/A (Oil acucumulation in engine room)- The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be in place to control leaks of flammable liquids. PSCO observed oil-soaked electrical wiring by LGSP-3 starter & by telephone booth on 2nd deco of ME. 74 SOLAS(09) II-2/4.1.1- 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2021Resolved
13199- N/A (other machinery)- After any survey of this ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. PSCO observed a crack and temporary repair on the sludge drain line. 74 SOLAS(20) I/11(b)- 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 November 2021Resolved
07126- N/A (Oil accumulation in engine room)- The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammanle liquids. PSCO observed oil-soaked lagging on the sludge drain line. 74 SOLAS(09) II-2/4.1.1- 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2021