DAIQUIRI is a 2009 tank ship. The Coast Guard has recorded 21 inspections since 2017, most recently in July 2026, along with 3 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 25 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it42010 - Convention (Subpart B), Gross Ton 22454 - Convention (Subpart B), Net Ton 73719 - Dead Weight, Metric Ton 89321 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 21
25 July 2026PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8444378
23 July 2026Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8465997
22 July 2026Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8444355
26 June 2026Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8416356
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 August 2025Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. It was reported and observed by marine chemist that failed flange gasket on the crude oil wash line in the cargo pump room caused a crude oil leak in the cargo pump room. Repair and test prior to cargo operations.
74 SOLAS (Amend.) II-2/4.1.1
abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2025
Resolved 13 August 2025
Resolution: Received, reviewed and accepted class report from DNV rectifying deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 May 2023Resolved
The foam concentrates of low-expansion fire-extinguishing systems shall be approved by the Administration based on the guidelines adopted by the organization. Vessel master was unable to provide up to date Foam Analysis report, foam analysis test low expansion service report indicated test result NOT ACCEPTABLE.
74SOLAS(09) II-2/10.8.1.1
FSS 6.2.3.1.1
IBC 11.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2023
Resolution: Received foam analysis report attesting to suitability
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 May 2023Resolved
Electrical equipment, cables, and wiring shall not be installed in the hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization. PSCO observed wasted cable glands for explosion proof lighting in upper level cargo pump room.
74SOLAS(20) VII/10.1
IBC 10.1.4
Action required: 10 - Deficiency Rectified
Resolved 11 May 2023
Resolution: Cable glands replaced by electrician
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National