Records from 2018 to 2025. Most recent: inspection, 24 November 2025.
Inspection history · 14
24 November 2025
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8273103
18 February 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8123043
6 November 2024
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8032043
6 February 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7860517
21 February 2023
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7623400
13 December 2022
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7607950
28 February 2022
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7403841
12 January 2021
Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7123411
18 March 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6928399
26 February 2020
Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6916694
29 April 2019
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6675290
9 April 2018
Damage Survey · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6387732
8 April 2018
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6388320
22 February 2018
COI Inspection · Deficiency Check · Hull Examination · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6360294
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 November 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The operator could not provide proof of the emergency instructions.
46 CFR 185.510/512
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 November 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
46 CFR 185.516
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 November 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry; three red hand flare distress signals and three orange hand smoke signals. The vessel is not so equipped.
46 CFR 180.68
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 November 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050. The grab line is not in accordance with the required specifications.
46 CFR 180.70
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 November 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in ISO 18813 or a kit with equivalent contents and instructions. The first aid kit inventory is not complete.
46 CFR 184.710
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 November 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The stowage location for the child life jackets is not properly marked.
46 CFR 180.78
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 November 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The restraining devices on the extinguisher brackets are not suitable.
46 CFR 181.520
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 November 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 2.5 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI. The vessel is not so equipped.
46 CFR 181.610
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2025
Resolved
Flexible hose installed in lengths of not more than 30 inches and subject to pressures of not more than 5 psig, may meet USCG Type A1, A2, B1, or B2. Portions of the fuel hose do not meet the required standard.
46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 10 December 2025
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 November 2025
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The electrical system has numerous, non-approved, blade type fuses in place.
46 CFR 183.380 (l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 10 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 November 2025
Resolved
Each vessel must be marked as required by 46 CFR part 67, subpart I, of this chapter. The stern of the vessel is not marked with the name and hailing port.
46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 10 December 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 November 2025
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the date of the training, and general description of the training topics. The operator could not provide proof of a training log.
46 CFR 185.420
Action required: 705 - Other - as specified
Due 24 December 2025
Resolved 10 December 2025
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 February 2023
Resolved
Each portable fire extinguisher must be on board in accordance with the COI. One portable fire extinguisher requires recharging.
Action required: 10 - Deficiency Rectified
Due 22 February 2023
Resolved 28 February 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2022
Resolved
Provide proof of state registration showing commercial passenger use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2022
Resolved 1 March 2022
Resolution: Registration was corrected to show commercial passenger.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 February 2022
Resolved
Place in service two additional hand held flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 1 March 2022
Resolution: Two USCG approved flares were placed on the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 February 2022
Resolved
Show proper operation of compass light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 21 March 2022
Resolution: Light was repaired on the magnetic compass.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2019
Resolved
Service 10:BC Fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2019
Resolved 29 April 2019
Resolution: Extinguisher was serviced and received proof.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2019
Resolved
Properly terminate dead end wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 21 May 2019
Resolution: Picture Received
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2019
Resolved
Provide and install Battery box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 21 May 2019
Resolution: Picture Received
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2019
Resolved
Provide and install new fuel line from tank to priming bulb.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 21 May 2019
Resolution: Picture Received
Documentation › Certificates/Documents › FCC SSL
Issued 21 March 2018
Resolved
Optain current FCC SSL.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2018
Resolved 10 May 2018
Resolution: Vessel owner received current FCC SSL.