← All vessels
QUEEN ELIZABETH
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Northwest District (CGD-NW) · Other hulls named QUEEN ELIZABETH
QUEEN ELIZABETH is a 2010 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2011, most recently in May 2026, along with 20 deficiencies and 1 operational control.
Records from 2011 to 2026. Most recent: inspection, 19 May 2026.
- Built
- 2010
- Last inspected
- 19 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9477438 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZCEF2
1041039
Flag
BERMUDA
—
Maury page id
psix-1041039
Inspections, by type
…with no type recorded4
Years with a record
10 calendar years (2011–2026)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it90901 - Convention (Subpart B), Gross Ton
50157 - Convention (Subpart B), Net Ton
7773 - Dead Weight, Ton
47263 - Displacement, Ton
50157 - Convention (Subpart B), Net Ton
7773 - Dead Weight, Ton
47263 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
19 May 2026
PSC A · COC-CVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8376611
2 May 2026
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8360562
21 December 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8285513
29 May 2025
COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8147271
28 May 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8145811
27 September 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8010639
22 August 2024
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7987808
29 March 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7905496
21 March 2024
COC-CVE Annual · PSC A
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7879986
23 October 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7813033
23 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7796158
3 June 2023
PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7702197
24 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542770
9 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529404
2 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7523040
13 May 2022
PSC B · COC-CVE Quarterly · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7446727
23 May 2019
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6753364
15 May 2019
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6680601
12 January 2018
COC-CVE Annual · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6337145
3 February 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6082480
10 January 2017
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6068507
9 February 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4250624
4 February 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4238289
18 January 2012
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4225914
21 September 2011
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4150545
19 September 2011
Ballast Water Examination · PII Safety Exam · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4149262
13 January 2011
ISPS II Exam · COC-CVE Initial
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3925939
Deficiency record · 20
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 June 2026
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The propeller shafting shall be so arranged that the propeller can be disengaged from the engine. Provision shall be made for ahead and astern propulsion of the lifeboat. Lifeboat 18 was incapable of astern propulsion.
74 SOLAS 20 III/34 LSA Code 4.4.6.5
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 June 2026
Resolved
Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, be of restricted fire risk determined in accordance with the Fire Test Procedures Code, and shall not restrict the passenger escape route. The Administration may permit additional seating in the main reception area within a stairway enclosure if it is fixed, non-combustible and does not restrict the passenger escape route. Furniture shall not be permitted in passenger and crew corridors forming escape routes in cabin areas. In addition to the above, lockers of non-combustible material, providing storage for non-hazardous safety equipment required by these regulations, may be permitted. Drinking water dispensers and ice cube machines may be permitted in corridors provided thye are fixed and do not restrict the width of the escape routes. This applies as well to decorative flower or plant arrangements, statues or others objects of art such as paintings and tapestries in corridors and stairways. Several portable chairs were found in multiple stairway landings and elevator landings.
74 SOLAS 20 II-2/5.3.3
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 June 2026
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire stations 9.I.02 and 9.III.01 doors were found stuck closed. Fire station 10.V.9 was found unable to be closed while fire hose was connected. Fire station 7.11.05 had multiple trash bags stored inside. Fire station in Deck 9 Lido Galley was blocked by dish trolley.
74 SOLAS 20 II-2/14.2.1.2
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2026
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Deck 12 AC station 12304 electrical cabinet was open, with too much equipment inside to close, and wires found on the deck. Deck 6 frame 282 had a low voltage panel missing an electrical cover.
74 SOLAS 04 II-1/40.1.3
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 June 2026
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI-1/1, or with applicable national standards of the Administration which provide an equivalent level of safety. Multiple cracks were found in crew stairwell near FSD 07.4.22. Significant corrosion resulting in a hole was found in A class bulkhead by FSD 10.2.38. Piping was found near FSD 07.01.56 from category 10 to category 3 through A Class bulkhead with gap found between pipe and bulkhead.
74 SOLAS 20 II-1/3-1
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 June 2026
Resolved
The purpose of this regulation is to contain fire in the space of origin. For this purpose, the following functional requirements shall be met: the ship shall be subdivided by thermal and structural boundaries. Insulation as found missing in door frame connecting passenger to crew area in vicinity of midship elevator outside stateroom 6118.
74 SOLAS 20 II-2/9.1.1
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 June 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Cardboxes, foam rolls, and flammable glue was found inside category 10 space, AC room 5604 with FSD 5.6.5.
74 SOLAS 20 II-2/9.2.2.3.2.2
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 March 2024
Resolved
74 SOLAS 20 II-2/9.2.2.3.2.2, 10(C)- Spaces are classified according to their fire risk as shown in categories (1) to (14). Pool equipment room is a category (10) space where storage of combustibles is prohibited, PSCO observed storage of cardboard boxes and other combustible materials stored within this space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2024
Resolved
74 SOLAS 20-22/13.3.2.3. 10(C)- Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustibles material providing storage for non-hazardous safety equipment and open information counters are permitted. PSCO observed hand sanitation stations and general information signs placed within category (2) stairway enclosures throughout the ship.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 March 2024
Resolved
74 SOLAS 20 II-2/4.4.2 10(C)- Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed a plastic waste receptacle with combustible material in one of the ship's galleys.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 3 June 2023
Resolved
Rescue boat launching arrangements shall be such that the rescue boat can be boarded and launched in the shortest possible time. The hydrostatic release mechanism on rescue boat/life boat #1 was not functioning properly and required manual release. 74 SOLAS 20 III/17.1 (16ac)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 June 2023
Resolved
The load line ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked. The deck line on the port side of the vessel was not painted with a contrasting color. ICLL 6 (50ac)
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 June 2023
Resolved
All survival craft required for the abandonment by the total number of persons on board shall be capable of being launched with their full complement of persons and equipment with in a period of 30 min from the time the abandon ship signal is given after all person have been assembled, with lifejackets donned. The team assigned to deploy life rafts on the port side of the vessel was unfamiliar with the launching procedures and could not meet the time requirements. 74 SOLAS 20 III/21.1.3 (10c)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. The fire door on deck 8 outside of cabin 8180 would not close. 74 SOLAS 20 II-2/9.4.1.1.5.1 (10c)
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 June 2023
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. Except as otherwise stated, the normal equipment of every life boat shall consist of a food ration totaling no less than 10,000 kJ for each person the lifeboat is permitted to accommodate. One ration on life boat #3 was torn open. 74 SOLAS III/34 LSA Code 4.4.8.12
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2022
Resolved
07105 - Fire doors/ openings in fire-resisting divisions - The construction of doors in door frames in "A" class divisions with the means of securing of them when closed, shall provide resistance to fire as well as to the passage of smoke and flame. Fire screen door 03.2.63 did not close. SOLAS 09 II-2/9.4.1.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2022
Resolved
07105 - Fire doors/openings in fire-resisting divisions - Where ventilation ducts with a free cross sectional area exceeding 0.075m2 shall be fitted with fire dampers... provided with an indicator which shows whether the damper is open or closed. Visual indication for automatic damper C0/310137ft found in fault status. SOALS 09 II-2/9.4.1.1.2
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 May 2019
Resolved
0715-fire detection-As required ships automatic sprinkler system shall include means for giving a visual and audible alarm signal automatically at one or more indicating units whenever any sprinkler comes into operation. Such alarm systems shall be such as to indicate if any fault occurs in the system. Such units shall indicate in which section served by the system a fire has occurred. While testing section valves in various locations around the vessel it was discovered that section 22 was indicated as the active location, no matter what section was tested. This does not indicate the actual location that was activated and may cause confusion when determining the fire location. Provide a class report attesting to the proper operation of the automatic sprinkler alarms and indicators.- SOLAS (2014) II-2 Reg 10.6.1.1/ FSS code Ch. 8.2.5.2.1
Lifesaving › Launching Appliances › Davit
Issued 12 January 2018
Resolved
Each survival craft shall be stowed in a state of continuous readiness so that two crew members can carry out preparations for embarkation and launching in less than 5 minutes. The launching appliance for the following lifeboats were inoperable. Lifeboats 6, 8, 9, and 18. Attending inspectors witnessed proper operation of all portside lifeboat launching appliances, and spot checked launching appliance on lifeboat 9 on stbd side. Vessel to notify Flag State of corrective action taken.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 January 2017
Resolved
Escape routes shall be maintained in a safe condition, clear of all obstacles. Oil drums and other obstacles are located in 1-95 that obstruct egress. IAW SOLAS (09) II-2/13.1.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.