MAURY USCG vessel records
← All vessels

BAKER SPIRIT

BAKER SPIRIT is a 2009 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in February 2026, along with 3 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 25 February 2026.

Built
2009
Last inspected
25 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9408073
1041621
Flag
BAHAMAS, THE
Maury page id
psix-1041621

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it83545 - Convention (Subpart B), Gross Ton
49022 - Convention (Subpart B), Net Ton
182539 - Displacement, Metric Ton
156929 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 19

25 February 2026 COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8316732
11 April 2025 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8110204
1 December 2024 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8041650
6 July 2024 PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7944617
29 June 2024 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7945043
24 June 2023 COC-TVE Annual · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7722023
2 September 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7549505
10 December 2021 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7361125
24 January 2020 COC-TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6877844
16 January 2019 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611312
16 December 2018 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6593017
26 March 2018 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6378664
23 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6360643
27 April 2017 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6114930
29 November 2016 MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6063500
18 November 2016 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6043831
27 April 2016 COC-TVE Renew · COE-Offshore · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5863633
27 April 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5864229
27 April 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5864240

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 March 2026 Resolved
A system for continuous monitoring of the concentration of hydrocarbon gases shall be fitted. Sampling points or detector heads shall be located in suitable positions in order that potentially dangerous leakages are readily detected. PSCO observed the fixed gas detection for cargo pump room and wing ballast tanks turned off. When energized the detection system was found inoperable. 74SOLAS(09) II-2/ 4.5.10.1.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2026
Resolved 5 March 2026
Resolution: Vessel has submitted class report attesting to corrective action taken. Report is in documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 March 2026 Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZORDOUES LOCATIONS UNLESS IT CONFORMS WITH STANDARS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED IMPROPER WIRING, LOOS WORES, EXPOSED WIRING, BROKEN PACKING GLANDS AND MISSING GROUNDS ON LIGHTING INSTALLED ALONG FRONT OF ACCOMODATION AND PUMP ROOM. ADDITIONALLY, PSCO OBSERVED LOOSE AND EXPOSED WIRING ON PUMP ROOM VENTILATION VALVE POSITION INDICATORS AND POWER SUPPLIED TO ODME PANEL IN PUMP ROOM. 74SOLAS(20) II-1/ 45.11 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2026
Resolved 5 March 2026
Resolution: Vessel has submitted class report attesting to corrective action taken. Report is in documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 February 2026 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with bolt hole pattern. PSCO observed the permanent stud not located at the top of the flange face 46CFR39.2001(j) 16c 10c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2026
Resolved 4 March 2026
Resolution: Vessel is removing current reducer and replacing it with the correct size.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.