MAURY USCG vessel records Sign in
← All vessels

IRMGARD SCHULTE

IRMGARD SCHULTE is a 2009 tank ship. The Coast Guard has recorded 17 inspections since 2020, most recently in December 2022, along with 4 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 2020 to 2022. Most recent: inspection, 5 December 2022.

Built
2009
Last inspected
5 December 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9410624 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1042272
Flag
ISLE OF MAN
—
Maury page id
psix-1042272

Inspections, by type

…with no type recorded10
Years with a record 3 calendar years (2020–2022)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it18311 - Convention (Subpart B), Gross Ton
5493 - Convention (Subpart B), Net Ton
23362 - Dead Weight, Ton
3330 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

5 December 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7604390
3 December 2022 COC-GAS Annual · PSC B · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7602674
1 December 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7602430
11 May 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7448263
15 October 2021 PSC B · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7333628
12 July 2021 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7253875
23 June 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7233517
23 June 2021 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7235003
6 June 2021 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7217253
6 June 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7217290
27 March 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7161907
24 March 2021 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7162043
7 January 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7119867
1 November 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7088875
10 September 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7054095
10 September 2020 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7054643
31 July 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7021059

Deficiency record · 4

14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 3 December 2022 Resolved
NBIC report not submitted per 33CFR151.2060(b)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 December 2022
Resolved 8 December 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 June 2021 Resolved
Gas detection equipment should be so designed that it may be readily be tested. During gas detection testing, found the gas sampling system for CT 1,2,3 &4 hold spaces (containing type c tanks) to be inoperable & not provide correct LEL % from span gas during testing. Corrected on the spot by re-calibration. 74 SOLAS (09) VII/13. IGC(93)13.6.6.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 July 2021
Resolved 6 June 2021
Resolution: Cleared on the spot by conducting a re-calibration of the system with appropriate span gas. Verified system was operational & provided sufficient alarms at 30% LEL of propane.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 June 2021 Resolved
On ships carrying flammable products, a water-spray system for colling, fire prevention, and crew protection should be installed to cover exposed cargo tank domes and cargo manifolds. Found 2/3 nozzles blocked on the #1 port tank dome , 1/3 nozzles on the #1 stbd tank dome, and 2/3 nozzles on the aft cargo manifold on the stbd. side. Corrected on the spot by blowing out the nozzles with water. 74 SOLAS (09) VII/13, IGC (93) 11.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 July 2021
Resolved 6 June 2021
Resolution: Cleared on the spot by having crew blow through nozzles with high pressure water spray. Re-conducted test, verified nozzles were in
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 September 2020 Resolved
Electrical equipment or wiring should not be installed in gas dangerous spaces or zones unless essential for operational purposes. PSCO observed an electrical wire dead ended at the aft of the rear of each compressor. The crew demonstrated that the wire was not carrying current and stated the wires were part of the vessel's original installation. The wire does not terminate within an explosion proof junction box. 74 SOLAS (2014) VII.13 / IGC 1993 Ch. 10.2.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 28 September 2020
Resolution: The junction boxes cables penetrations glands have been satisfactorily renewed using original spare glands with plugs. After cables removal the remaining cables have been satisfactorily secured. The repair now carried out may be considered permanent.

Ownership record