MAETIGA is a 2009 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in June 2025, along with 5 deficiencies and 4 operational controls.
Records from 2016 to 2025. Most recent: inspection, 19 June 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it46925 - Dead Weight, Metric Ton 56232 - Displacement, Metric Ton 12017 - Convention (Subpart B), Net Ton 29304 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 19 June 2025Resolved
TO DISCHARGE BALLAST WATER INTO WATERS OF THE UNITED STATES, THE MASTER, OWNER, OPERATOR AGENT, OR PERSON IN CHARGE OF A VESSEL SUBJECT TO 151.2025 OF THIS SUBPART MUST EITHER ENSURE THAT BALLAST WATER MEETS THE BALLAST WATER DISCHARGE STANDARD AS DEFINED IN 151.2025(A)(3) OR BALLAST EXCLUSIVELY WITH WATER FROM A US PUBLIC WATER SYSTEM.
VESSEL REPORTED LACK OF SUCTION ON MAIN BALLAST WATER TREATMENT PIPING CAUSING THE TREATMENT SYSTEM TO SHUT DOWN UPON DISCHARGE. SYSTEM REQUIRES TREATMENT UPON UPTAKE AND DISCHARGE. VESSEL IS NOT AUTHORIZED TO DISCHARGE UNTREATED BALLAST INTO THIS WATERS OF THE US WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE CAPTAIN OF THE PART UNDER UNDER PROVISIONS OF 33CFR151.2040(b).
Action required: 15 - Rectify deficiencies by next port
Resolved 28 July 2025
Resolution: On 27 June 2025 at Cristobal (Panama), the system was verified by NKK class surveyor, tested and found to be in normal working condition to the satisfaction of attending surveyor.
Vessel’s ballast water treatment system is operating in good order.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2020Resolved
Participating ships must make report to the U.S. Coast Guard upon entering the area covered by a reporting system. The vessel failed to report when it had entered WHALESNORTH as defined in 33CFR169.105.
Action required: 705 - Other - as specified
Due 19 June 2020
Resolved 19 June 2020
Resolution: This activity was referred to enforcement.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2018Resolved
AN ALARM SYSTEM SHALL BE PROVIDED INDICATING ANY FAULT REQUIRING ATTENTION AND SHALL: BE CAPABLE OF SOUNDING AN AUDIBLE ALARM IN THE MAIN MACHINERY CONTROL ROOM OR AT THE PROPULSION MACHINERY CONTROL ROOM POSITION, AND INDICATE VISUALLY EACH SEPARATE ALARM FUNCTION IN A SUITABLE LOCATION. SIGNAL LIGHT COLUMN IN THE ENGINE ROOM DOES NOT RESPOND TO ALARM SYSTEM. 74 SOLAS (14) II-1/51.1.1
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2018
Resolved 4 July 2018
Resolution: BASED ON CLASS REPORT SHOWING SATISFACTORY CORRECTIONS, THE DEFICIENCY HAS BEEN CLEARED.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 1 July 2018Resolved
EACH OPERATION DESCRIBED IN PARAGRAPH 2 OF THIS REGULATION SHALL BE FULLY RECORDED WITHOUT DELAY IN THE OIL RECORD BOOK PART 1. 02 BUNKERING ENTRIES WERE MISSING.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 July 2018
Resolved 1 July 2018
Resolution: Entries were noted in the Oil Record Book.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2018Resolved
MAINTENANCE, TESTING, AND INSPECTION SHALL BE CARRIED OUT B ASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION AND IN A MATTER HAVING DUE REGARD TO ENSURING THE RELIABILITY OF FIRE-FIGHTING SYSTEMS AND APPLIANCES. LAST CO2 SERVICING DATE WAS 02JUN2017-OVERDUE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2018
Resolved 4 July 2018
Resolution: BASED ON CLASS REPORT SHOWING SATISFACTORY CORRECTIONS, THE DEFICIENCY HAS BEEN CLEARED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.