Records from 2011 to 2019. Most recent: inspection, 15 August 2019.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Inflatable Liferafts › Float Free
Issued 14 February 2011
Resolved
Found life raft tied to cradle with cable wire, life raft not immediately available for use or deployment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 February 2011
Resolved
Found all PFD's with no markings indicating vessel name.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2011
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 14 February 2011
Resolved
Found several PFD's with inoperable PFD lights and missing whistles
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 14 February 2011
Resolved
Found all 7 portable fire extinguishers either expended or with no means of activation. Vessel incapable of properly combatting a fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2011
Stability › Watertight Integrity › General
Issued 14 February 2011
No resolution recorded
Found hatches missing gaskets ensuring watertight integrity
Action required: 15 - Rectify deficiencies by next port
Documentation › Markings/Placards › Garbage Placard
Issued 14 February 2011
No resolution recorded
Provide and post garbage placards in common areas.
Action required: 15 - Rectify deficiencies by next port
Documentation › Markings/Placards › Oil Discharge Placard
Issued 14 February 2011
No resolution recorded
Provide and post oil discharge placards in machinery areas
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 14 February 2011
No resolution recorded
Found vessel with no installed MSD tyep II or MSD typ III sewage device
Action required: 15 - Rectify deficiencies by next port
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 14 February 2011
No resolution recorded
Found vessel with no Oil Transfer Procedures
Action required: 703 - Prior to bunkering operations
Communications › Radio Communications › EPIRB
Issued 14 February 2011
Resolved
Found EPIRB with expired hydro static release
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 14 February 2011
Resolved
Found vessel with no Semi -portable B-III fire extinguisher for engine room. Vessel incapable of properly combatting a fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2011
Lifesaving › Lifebuoys › Quantity
Issued 14 February 2011
Resolved
Found 1 out of 3 ring bouys in severely deteriorated condition, deteriorated ring bouy incapable of providing flotation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 14 February 2011
Resolved
Found overbaord sewage piping in the open position allowing direct overboard discharge.
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 14 February 2011
Communications › Radio Communications › EPIRB
Issued 14 February 2011
Resolved
Found Cat 1 EPIRB installed in Masters cabin and incapable of being float free.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011