MAURY USCG vessel records Sign in
← All vessels

ALEXANDROS PETRAKIS

ALEXANDROS PETRAKIS is a 2008 freight ship. The Coast Guard has recorded 15 inspections since 2010, most recently in October 2024, along with 13 deficiencies and 4 operational controls.

Records from 2010 to 2024. Most recent: inspection, 27 October 2024.

Built
2008
Last inspected
27 October 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9442938 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A4307
1043335
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1043335

Inspections, by type

…with no type recorded4
Years with a record 7 calendar years (2010–2024)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39737 - Convention (Subpart B), Gross Ton
39737 - Simplified, Gross Ton
25754 - Convention (Subpart B), Net Ton
25754 - Simplified, Net Ton
76596 - Dead Weight, Metric Ton
86824 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

27 October 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8025218
25 October 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8019873
5 October 2021 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7320695
22 March 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6643642
5 April 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6386186
27 March 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6372931
24 March 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6377830
30 November 2015 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5765919
24 November 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5769150
23 November 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5769165
23 September 2015 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5717390
3 August 2015 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5205369
14 May 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4306667
6 November 2010 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 3886118
3 November 2010 ISPS I Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3882344

Deficiency record · 13

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 October 2021 Resolved
02107-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCO discovered severe leak on a ballast discharging pipe that was causing flooding in the bilge. 74 SOLAS 20 Chapt. 1 Reg 11 (a)-17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2021
Resolved 6 October 2021
Resolution: Vessel provided Class Survey Report attesting to temporary repairs on the BWTS pipeline. Class NK has issues a temporary condition of class for permanent repairs to be completed by 30Nov21.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 March 2019 Resolved
02199 - THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PIPING ON THE VESSEL’S SALT WATER COOLING SYSTEM HAS APPROXIMATELY 10 LEAKS WITH TEMPORARY REPAIRS MADE BY THE CREW WITHOUT APPROVAL OF THE VESSEL’S CLASSIFICATION SOCIETY. 74 SOLAS 74 (04) II-1/26.1, 30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 22 March 2019
Resolved 27 March 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 March 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 30 - Ship detained
Due 22 March 2019
Resolved 27 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2019 Resolved
13199- ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. LOSS OF POWER ALARM FOR STEERING GEAR PUMP # 1 DOES NOT ALARM IN THE ENGINE ROOM OR BRIDGE. DURING STEERING GEAR TESTS, EXCESSIVE HYDRAULIC OIL LEAKS WERE IDENTIFIED ON BOTH PUMPS AND ON THE HYDRAULIC RAM. 74SOLAS (04)II-1/29.2.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2019
Resolved 27 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 March 2019 Resolved
11112- THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. LOWERING MECHANISM FOR PORT SIDE LIFEBOAT DAVIT LAUNCH HAS EXCESSIVE CORROSION. 74SOLAS (14)I/11 (a) 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2019
Resolved 27 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 March 2019 Resolved
07113- FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. MULTIPLE TEMPORARY PATCHES WERE FOUND ON THE FIRE MAIN PIPING AND WERE ACTIVELY LEAKING FROM THE FIRE AND GENERAL SERVICE PUMPS PACKING GLADS. 74SOLAS (09)II-2/14.2.1.2 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2019
Resolved 27 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 March 2019 Resolved
11135- EXCEPT AS PROVIDED IN PARAGRAPHS 3.3.4 AND 3.3.5, EACH LIFEBOAT SHALL BE LAUNCHED, AND MANOEUVRED IN THE WATER BY ITS ASSIGNED OPERATING CREW, AT LEAST ONCE EVERY THREE MONTHS DURING AN ABANDON SHIP DRILL. CREW FAILED TO PROVIDE DOCUMENTATION FOR REQUIRED LOWERING AND LAUNCHING OF PORT SIDE LIFE BOAT. 74SOLAS (14)III/19.3.3.3 16AC
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2019
Resolved 27 March 2019
Communications › Radio Communications › EPIRB
Issued 23 September 2015 Resolved
1671-EPRIB-Every ship shall be provided with a satellite emergency position-indicating radio beacon which shall be capable of floating free. Satellite emergency position-indicating radio beacon is installed with a liferaft hydrostatic release. 74SOLAS(14)IV/7.1.6.6.4 - 17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2015
Resolution: Recieved notification of EPIRB hydrostatic release purchased.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 23 September 2015 Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall, in the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the bridge. The bridge received no audible or visual alarm during loss of power test. 74 SOLAS(04)Ch.II-1/29.8.4-40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2015
Resolution: Recieved class report and attended vessel verifying audible and visual alarms were recieved on bridge for loss of power of steering system
Lifesaving › Liferaft Equipment › First-aid Kit
Issued 23 September 2015 Resolved
Cargo ships shall carry one or more totally enclosed lifeboats complying with section 4.6 of the code. Port and starboard lifeboats do not have sufficient anti-seasickness medicine for at least 48 hours for each person. 74SOLAS(14)Ch.III/31.1.1.1-40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2015
Resolution: Received class report and attended vessel to confirm port and starboard lifeboats have sufficient anti-seasickness medicine.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 23 September 2015 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The diesel oil transfer pump and the fuel oil transfer pump are excessively leaking. 74SOLAS(14)Ch.I/II(a)-40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2015
Resolution: Received class report and attended vessel confirmining the DO transfer pump and FO tansfer pump had no leaks during operational test.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 14 May 2012 Resolved
0799- Other(Fire Fighting Equipment) - Fire fighting systems shall be readily available for immediate use. Ship's water mist system pump discharge valves were in the closed position. Reviewed Operations Manual and found that the systems valves should remain open. SOLAS74a II-2/14
Action required: 705 - Other - as specified
Due 14 May 2012
Resolved 14 May 2012
Resolution: Discussed with C/E and [name withheld] were opened on the spot.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 14 May 2012 Resolved
0799- Other(Fire Fighting Equipment) - Fire fighting systems shall be readily available for immediate use. Ship's fixed foam system pump discharge valves were in the closed position. Reviewed Operations Manual and found that the systems valves should remain open. SOLAS74a II-2/14
Due 14 May 2012
Resolved 14 May 2012
Resolution: Discussed with C/E and [name withheld] were opened on the spot.

Ownership record