Records from 2016 to 2025. Most recent: inspection, 14 August 2025.
Documentation record
Registered dimensions (L × B × D)64.5 ft × 22.0 ft × 10.3 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNO. AMERICAN ROCKWELL COR · NEW BERN, NC, UNITED STATES · built 1970
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGIG HARBOR, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 6 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
14 August 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8209547
23 October 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8024181
15 July 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7956245
5 February 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7861121
7 July 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7736258
7 July 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7741945
24 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7575144
20 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7488711
21 April 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7176678
5 October 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7074305
10 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6973200
4 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6828571
11 September 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809514
9 May 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6680786
17 October 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6560320
16 May 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6415450
21 April 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6127892
6 September 2016
Damage Survey · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6026069
25 April 2016
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5854326
28 January 2016
Type not recorded
No type recorded · Station Bellingham · USCG Northwest District (CGD-NW) · Activity 5807362
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 August 2025
Resolved
For alcohol testing, the marine employer shall have a sufficient number of alcohol testing devices readily accessible onboard the vessel. Vessel did not have alcohol testing devices on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2025
Resolved 21 August 2025
Resolution: O/o provided pictures of the new alcohol swabs.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 15 July 2024
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. MI observed the EPIRB hydrostatic release to have not been marked with the expiration date when installed. Based on the date of purchase, May 2021, hydrostatic release expired May 2023.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: O/O provided sufficent photographs detailing a new hydrostatic release installed, marked with an expiration date.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 July 2024
Resolved
Each dead cover must be designed so that it can be secured watertight. MI observed 04 dead light covers in overnight accommodation spaces below the bulkhead deck to not have the ability to be sealed watertight and latches to secure covers were heavily corroded rendering them inoperable.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 29 August 2024
Resolution: Owner/operator provided sufficent video showing satisfactory correction of deficency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 July 2024
Resolved
A hatch cover must be attached to the hatch frames or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. MI observed 02 hatch covers on the FWD deck to be missing a means of attachment to the hatch frames.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 29 August 2024
Resolution: Owner/operator provided sufficent photo showing satisfactory correction of deficency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 July 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Marine inspector observed expired aspirin to be in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 25 July 2024
Resolution: O/O provided sufficent photgraphs to prove they have aspirin onboard the vessel for the first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 July 2023
Resolved
All engines must have at least two means for stopping under any operating conditions. Vessel's main engine could not be stopped under normal operating conditions. Please provide a report of full functionality.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2023
Resolved 10 July 2023
Resolution: Vessel owner provided report for full generator functionality.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 20 June 2022
Resolved
Electrical equipment on a vessel must be installed to protect passengers from electrical hazards. Dead end wires found by inspectors under bridge console.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2022
Resolved 4 July 2022
Resolution: [name withheld] sent in photos via email of the dead end wires with caps
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 June 2022
Resolved
Each survival craft must be stowed so that when the vessel sinks it floats free and if inflatale it inflates automatically. Liferaft stowage arrangement found to be installed incorrectly with strong link unable to connect to the VSL.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2022
Resolved 4 July 2022
Resolution: [name withheld] sent in photos via email of the corrected liferaft arrangement which sufficiently demonstrated the proper stowage
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2020
Resolved
Cable connecting batteries in series has a sharp bend. Remedy sharp bend in cable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 11 June 2020
Resolution: Replaced short cable linking the batteries in series with no sharp bends.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2019
Resolved
In accordance with the Small Passenger Vessel Inspection Direction, from 16SEP19. An 835V was issued to the vessel because the owner was unable to make the vessel available for inspection before 14OCT19. The vessel can not accommodate overnight passengers until ONA CIC is completed.
Action required: 705 - Other - as specified
Due 4 October 2019
Resolved 10 June 2020
Resolution: Verified compliance of items listed SPV Overnight Accommodations Job Aid with [name withheld] was conducted virtually due to COVID-19.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2019
Resolved
Demonstrate proper operation of currently inoperable bilge pump in Shaft Alley. 46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 20 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 May 2019
Resolved
Provide valis Radio Safety Telephony certificate. 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 4 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 May 2019
Resolved
Provide required number of acceptable flare (currently expired). 46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 20 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2019
Resolved
Prode required number (5) of Type I child life jackets. Vessel may not operate with more than 2 child children until life jackets are provided. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 20 May 2019
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 May 2018
Resolved
Provide proof of purchase and place on board updated Coast Guard Light List IAW 46 CFR 185.20-35.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 1 June 2018
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 May 2018
Resolved
Provide proof of purchase and place onboard updated US Coast Pilot IAW 46 CFR 185.20-35.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 1 June 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2018
Resolved
Properly install machinery guard on aft machinery belt on main engine IAW 46 CFR 177.35-15.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 9 June 2018
Resolution: Installed machinery guard.
Documentation › Markings/Placards › Warning Signs
Issued 16 May 2018
Resolved
Place emergency broadcast placard next to radion equipment IAW 46 CFR 176.25-30.
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 1 June 2018