Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it7833 - Regulatory (Subpart C or D), Gross Ton 7833 - Convention (Subpart B), Gross Ton 3626 - Convention (Subpart B), Net Ton 3626 - Regulatory (Subpart C or D), Net Ton 10736 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
3 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
2 December 2016Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6051724
2 December 2016Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6051757
17 March 2016ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5828674
EACH TANKSHIP TO WHICH THIS PART APPLIES MUST HAVE AN INERT GAS SYSTEM WITH AN APPROVED DECK SEAL. PRIOR TO CONDUCTING CARGO OPS PROVIDE AN ATTENDING CLASSIFICATION SOCIETY SURVEYOR REPORT CERTIFYING THE VESSEL'S INERT GAS GENERATOR DOUBLE BLOCK AND BLEED CONFORMS TO THE REQUIREMENTS IN THE INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES (IACS) UNIFIED REQUIREMENTS F20.3.3 REV. 6 2012
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2016
Resolved 5 December 2016
Resolution: Received class statement addressing and certifying the vessel's double block and bleed meets IACS standards.
1740 - POLLUTION PREVENTION - OIL TANKERS OF 150 GROSS TONNAGE AND ABOVE SHALL BE EQUIPPED WITH AN OIL DISCHARGE MONITORING AND CONTROL SYSTEM APPROVED BY THE ADMINISTRATION; VESSELS ODME IS NOT OPERATIONAL. - MARPOL ANNEX I/31.1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2016
Resolution: Received class report verifying ODME is operational.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 17 March 2016Resolved
9900 - STRUCTURAL ZONES - WHERE A CLASS DIVISIONS ARE PENETRATED, SUCH PENETRATIONS SHALL BE TESTED IN ACCORDANCE WITHTHE FIRE TEST PROCEDURES CODE; VESSEL HAS INSTALLED CABLE PASSAGE USING A STEEL PIPE PACKED WITH COMMON SILICONE BETWEEN DECK "PIPE TRUNK" AND "UNDER FORCASTLE STORAGE" SPACES. - SOLAS(74)II-2/9/3.1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2016
Resolution: Received class report attesting to proper cable installation.
Deck/Cargo › Inert Gas System › Deck Mechanical Non-Return Valve
Issued 17 March 2016No resolution recorded
0199 - INERT GAS SYSTEM - EACH TANKSHIP TO WHICH THIS PART APPLIES MUSTHAVE AN INERT GAS SYSTEM WITH AN APPROVED DECK SEAL. VESSELS MAIN LINE AND N2 MAIN LINE ARE EQUIPPED WITH DOUBLE BLOCK AND BLEED ARRANGEMENTS AND VESSEL CANNOT PROVIDE USCG APPROVAL LETTER. - 33CFR 32.53-10
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2016 — due date passed with no resolution recorded
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.