OCEAN PEARL is a 2009 freight ship. The Coast Guard has recorded 28 inspections since 2010, most recently in January 2026, along with 6 deficiencies and 8 operational controls.

Records from 2010 to 2026. Most recent: operational control imposed, 22 January 2026.

Built
2009
Last inspected
22 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9401829 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1044282
Flag
BAHAMAS, THE
—
Maury page id
psix-1044282

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (2010–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it29829 - Simplified, Gross Ton
29829 - Convention (Subpart B), Gross Ton
15810 - Simplified, Net Ton
15810 - Convention (Subpart B), Net Ton
60497 - Displacement, Metric Ton
51758 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

22 January 2026 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8299995
21 January 2026 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8299193
23 December 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8286758
16 October 2025 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8250426
3 August 2025 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8202121
3 August 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8203167
9 June 2025 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8155436
5 June 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8152534
21 March 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8097614
3 March 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8084151
4 September 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7992198
29 August 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7992283
8 August 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7764690
14 June 2023 PSC B · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7704566
31 March 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7660810
27 September 2022 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7567449
19 November 2021 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7354303
9 August 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7281612
6 July 2021 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7247137
21 April 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7180418
7 February 2020 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6904645
17 July 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6753000
22 May 2019 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6685502
26 February 2019 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6633188
17 May 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6410816
26 January 2018 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6343712
26 April 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6132954
8 September 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3845503

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 June 2023 Resolved
Hydraulic power-operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuated system including the reservior. PSCO observed that the fixed storage tank was empty. 74 SOLAS (2009 cons) II-1/29.12.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2023
Resolution: Vessel provided a class report stating that the empty hydraulic tank for the steering gear had been filled to the sufficient level.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2023 Resolved
The condition of the ship and its equipment shall be maintained. PSCO obsedrved a doubler on the raw water inlet side of the cooling system. 74 SOLAS (2020 cons.) 1/11(a) 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 June 2023
Resolution: Vessel submitted class report attesting to repair of the sea water inlet pipe and successful hydrostatic test of lines.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 June 2023 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed #1 service generator had 1 of 2 water mist nozzles blocked, PSCO had crew remove. 74 SOLAS II-2/14.1.1 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 14 June 2023
Resolution: Corrected on the spot by removing the materials blocking the nozzle.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 June 2023 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Quick closing valves for the D.O. Serv. TK were blocked at the time of the exam. 74 SOLAS II-2/14.1.1 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 June 2023
Resolution: Corrected on the spot by removing the bolts blocking the quick closing valves and providing dcumentation that they had conducted testing of the valves within the past 24 hours.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 July 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of he present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Master reported damage to the vessel which occurred while mooring at the port. PSCO attended the vessel and observed a gouge in the port side hull on the outside of the ballast tank approximately 15 feet(4.6 meters) in length with a 1.5 inch (3.8 centimeters) inset resulting from an exposed shackle due to lack of fendering on the port.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2019
Resolution: DNV GL Class Survey indicated No further action or repairs required as the indent is considered within acceptable tolerances and of no significance.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 22 May 2019 Resolved
The 15 ppm bilge alarm should record date, time and alarm status and operating status of the 15 ppm bilge separator. The recording device should store data for at least 18 months and should be able to display or print a protocol for official inspections. Crew was unable to retrieve data.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2019
Resolved 25 May 2019
Resolution: Received Class report attesting to the correction of this deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.