MAURY USCG vessel records
← All vessels

GERAKAS

GERAKAS is a 2009 tank ship. The Coast Guard has recorded 35 inspections since 2016, most recently in January 2026, along with 14 deficiencies and 8 operational controls.

Records from 2016 to 2026. Most recent: inspection, 15 January 2026.

Built
2009
Last inspected
15 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 January 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9399894
1044598
Flag
PANAMA
Maury page id
psix-1044598

Documentation record

Tonnage as PSIX records it30040 - Regulatory (Subpart C or D), Gross Ton
13312 - Regulatory (Subpart C or D), Net Ton
30040 - Convention (Subpart B), Gross Ton
13312 - Convention (Subpart B), Net Ton
49997 - Dead Weight, Metric Ton
60119 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

35 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; 8 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 35

15 January 2026 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8293636
10 June 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8156300
16 April 2025 PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8110244
8 March 2025 PSC A · Deficiency Check · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8090421
9 February 2024 Administrative Inspection · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7862020
23 June 2023 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7721509
10 May 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7684996
10 May 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7690021
17 February 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7638262
18 August 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7537191
27 March 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7419240
7 February 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7389610
18 September 2021 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7315100
7 April 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7170707
31 March 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7167597
25 March 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7163034
9 February 2021 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7138578
8 February 2021 COC-CHEM Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7136434
6 February 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7136858
13 December 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7110994
27 January 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6894827
14 January 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6889405
2 December 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6865607
15 September 2019 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6812450
22 August 2019 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6791534
22 August 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6795911
18 August 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6786919
27 May 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6695651
22 May 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6690906
11 March 2019 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6639943
12 September 2018 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6538784
12 September 2018 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6539125
26 January 2018 COC-TVE Renew · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6343964
26 May 2017 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6153433
28 March 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5840009

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 April 2025 Resolved
Eletrical installations shall be such as to minimize the risk of fire and explosion from flammable products. Emergency shut down device on PIS not maintained intrinsically safe. 74 Solas (20) VII/10.1 IBC 10.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: The vessel used the appropriate electical putty to repair wasted conduit.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 16 April 2025 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for which they are intended... will be subjected and the environment conditions on board. Boiler had large steam leak at top valve. 74 SOLAS (20) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: Vessel crew repaired boiler.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 10 March 2025 Resolved
The company and the ship shall comply with the requirements of the International Safety management Code. The Company should establish procedures to ensure that the ship is maintained in conformance with provisions of relevant rules and regulations and with any additional requirements which may be established by the company. The technical and operational nature of deficiencies 02-08 provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency. 74SOLAS(20) IX/3.1 ISM Code 10.
Action required: 30 - Ship detained
Resolved 16 March 2025
Resolution: LR ISM audit attesting to satisfactory compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 10 March 2025 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliance shall be in working order and readily available for immediate use. PSCO observed starboard lifeboat unable to start and operate as required. Observed lifeboat sputtering and the inability to remain running. 74SOLAS(20) III/20.2
Action required: 30 - Ship detained
Resolved 12 March 2025
Resolution: Class report attesting to satisfactory rectification.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 March 2025 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be installed and protected so as to reduce to a minimum any dangers to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed approximately 2 inches of pooling lube oil leaks under generators 1, 2, and 3. 74SOLAS(04) II-1/26.1
Action required: 30 - Ship detained
Resolved 12 March 2025
Resolution: Class report attesting to satisfactory rectification.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 March 2025 Resolved
Maintenance, testing, and Inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire protection systems and appliances. PSCO observed crew unable to conduct testing on flame detectors in the engine room due to required testing equipment being inoperable since 25JAN2025 as noted on procurement order from crew. Further PSCO observed flame detection logged as tested after equipment was reported broken and new tester was ordered. Crew informed PSCO that they had not tested detectors. PSCO observed monthly testing checklist missing instructions for testing flame detectors. 74SOLAS(09) II-2/14.2.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Class report attesting to satisfactory rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the persons on board. PSCO observed bonding straps broken and/or missing on cargo deck piping systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Class report attesting to satisfactory rectification.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 March 2025 Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical Code and shall, in addition to the requirements of I/8, I/9, and I/10, as applicable, be surveyed and certified as provided for in that code. For the purpose of this regulation the requirements of the code shall be treated as mandatory. The stowage space shall be : .1 cell divided in order to avoid shifting of the bottles at sea. PSCO observed Annex I and Annex II sample bottles not cell divided with full bottles on their sides and rolling around. 74 SOLAS(20) VII/10.1 IBC 16.5.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Class report attesting to satisfactory rectification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 March 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the persons on board. PSCO observed multiple cargo tank man hole covers with missing studs and nuts. 74SOLAS(20) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2025
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 10 March 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the persons on board. PSCO observed debris floating in deck water seal. 74SOLAS(20) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2023 Resolved
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. VESSEL REPORTED THAT SHIP BECAME STUCK AT HALF AHEAD WHILE TRANSITING IN INNER ANCHORAGE.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 May 2023
Resolution: Port State Control received class survey report stating that main engine (M/E) fuel linkages were examined and M/E satisfactorily passed ahead and astern propulsion tests in surveyors presence.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 7 February 2022 Resolved
12108 - Suitably marked decontamination showers and eyewash stations shall be available on deck in convenient locations. The portside decontamination shower supply water piping was wasted. The decontamination supply valve was secured, rendering both port and starboard side showers inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 February 2022
Resolved 27 March 2022
Resolution: Vessel removed insulation, repaired damaged areas in supply lines, and painted. Class report received verifying proper work completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 March 2019 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids... The number two fuel pump on main engine hd substantial leak. - 74SOLAS(09) II-2/4.1 - 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 15 March 2019
Resolution: Received, reviewed and approved LR class report.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 March 2016 Resolved
0611-Lifeboat inventory-Each survival craft shall be equipped as required; the normal equipment of every lifeboat shall consist of a food ration for each person the lifeboat is permitted to acoommodate and shall be kept in airtight packaging. PSCO observed 19 of the required 54 rations were not kept in airtight packaging. SOLAS III/13.4, LSA 4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2016
Resolved 31 March 2016
Resolution: Received, reviewed and accepted proper documentation from the World [name withheld] stating the deficiency was rectified. All of the food rations on board were replaced. Shipping papers were sent in and confirmed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.