Records from 2009 to 2026. Most recent: inspection, 26 February 2026.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portST JAMES CITY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
26 February 2026
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8311399
8 December 2025
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8282259
24 September 2025
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8238652
16 January 2025
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8063324
11 October 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8028341
4 March 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7871637
11 September 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7789224
28 March 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7657841
25 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7583348
11 April 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7428459
15 September 2021
Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7311810
27 October 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7084362
4 December 2019
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6865645
29 October 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6841875
5 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6635759
24 January 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6342394
16 October 2017
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6285649
24 January 2017
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6074091
14 March 2016
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5830697
28 October 2015
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5735500
10 March 2014
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4811412
9 December 2009
Administrative Inspection · Initial Certification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3647187
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 September 2025
Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. The vessel name is not clearly marked on the port, starboard, and stern. The vessel hailing port is not clearly marked on the stern.
46CFR185.602
Action required: 705 - Other - as specified
Resolved 7 November 2025
Resolution: The vessel name is now clearly marked on the port, starboard, and stern. The vessel hailing port is now clearly marked on the stern. The vessel is now marked as required by part 67, subpart I, of this chapter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 April 2022
Resolved
The portside forward bilge pump is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Received video of working bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2022
Resolved
Ring buoy light is inoperable. Restricted to day light hours until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Received video of working ring buoy light.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 11 April 2022
Resolved
Replace all expired items in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: New first aid kit provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 April 2022
Resolved
Could not verify call sign or MMSI number with VHF radio. Performed successful radio check. Verify MMSI & call sign with FCC certificates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: New Radio Safety Certificate issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2022
Resolved
Fuel lines are single clamped at connection points. Double clamp each connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Received photos of double clamped fuel lines.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 April 2022
Resolved
Provide additional 04 red hand flares for 12 total.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Received photos of hand flares.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2022
Resolved
Provide current chart, light list, tide tables and Coast Pilot for navigation area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Received photos of publications.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2022
Resolved
Starboard fuel tank is missing "Emergency Fuel Shutoff" label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Fuel shut off label provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2022
Resolved
Child lifejacket stowage is not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Received photo of labeled storage.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2022
Resolved
01 fire bucket is missing a grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: Fire bucket has a grab line.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 April 2022
Resolved
Provide proof of EPIRB registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 1 July 2022
Resolution: EPIRB registered.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 October 2020
Resolved
Monthly checks of EPIRB are not being logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2020
Resolved 10 November 2020
Resolution: Received photo of updated log book.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 October 2020
Resolved
Emergency drills are not being logged - required every 03 months.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2020
Resolved 10 November 2020
Resolution: Received photo of updated log book.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 October 2020
Resolved
Replace 01 missing fire bucket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Replaced missing bucket.
Construction/Loadline › Hull › Hull Plating
Issued 28 October 2015
Resolved
Vessel had areas that needed repair on both port and starboard hulls. All were noted as water blisters between bottom paint and gelcoat, some where into the first layer of glass. Stbd bow at main deck level had are that needed repair. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 2 November 2015
Resolution: Repairs were made to areas identified during inspection. Areas were ground to good glass and repaired with epoxy. All SAT
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 March 2014
Resolved
Provide proof of current contract with an approved consortium, list of current employees in the consortium, 2013 MIS report and EAP training for the deckhands and documentation fo random drug testing for all employees IAW 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2014