MAURY USCG vessel records
← All vessels

GRAND LEGACY

GRAND LEGACY is a 2008 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in October 2022, along with 7 deficiencies and 5 operational controls.

Records from 2016 to 2022. Most recent: inspection, 18 October 2022.

Built
2008
Last inspected
18 October 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 October 2022
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9355240
1045530
Flag
PANAMA
Maury page id
psix-1045530

Documentation record

Tonnage as PSIX records it25002 - Displacement, Metric Ton
59217 - Convention (Subpart B), Gross Ton
17766 - Convention (Subpart B), Net Ton
8075 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

18 October 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7579536
23 November 2020 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7100316
20 November 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7099230
24 February 2020 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6913196
19 February 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6911666
18 February 2020 PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6910474
15 February 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6915378
11 February 2020 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6906717
9 February 2020 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6905936
9 February 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6906079
7 February 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6907943
27 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6727836
21 June 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6714613
23 May 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6418246
16 March 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6103285
29 January 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5805778
28 January 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5804911

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 February 2020 Resolved
Manually operated call points complying with the FSS code shall be installed throughout the accomodation spaces, service spaces, and control stations. During routine maintenance tests, the manually operated call point by the port side bunker station was not operational. Vessel provided purchase order for a new call point unit. PSC Examiners tested 02 smoke detectors near the port side bunker station, that were found to be operational. 74SOLAS(04) II-2/7.7 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 November 2020
Resolution: MSU Savannah received Korean Regsiter class report satisfying the requiprment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2020 Resolved
13199 - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PSCO OBSERVED TEMPORARY REPAIRS TO CRANKCASE DOORS # 3, 4, 5, AND 6. [name withheld] DOOR #6 AND A CRACK WAS OBSERVED ON THE OPPOSITE SIDE OF THE TEMPORARY REPAIR. 74SOLAS(14)I/11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2020
Resolved 11 February 2020
Resolution: Received class report stating that the deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2020 Resolved
09209 - ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN A NORMAL MANNER. THE TEMPERATURE SENSOR ON THE NO. 1 WASTE OIL TANK HAS A BROKEN COVER AND EXPOSED ELECTRICAL WIRES. 74SOLAS(04)II-1/45.1.3
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2020
Resolved 11 February 2020
Resolution: Received class report stating that the deficiency was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2020 Resolved
13199 - EVERY STEAM GENERATING SYSTEM WHICH COULD BE RENDERED DANGEROUS BY THE FAILURE OF ITS FEEDWATER SUPPLY, SHALL BE PROVIDED WITH NOT LESS THAN TWO SEPARATE FEEDWATER SYSTEMS FROM AND INCLUDING THE FEED PUMPS. THE FEEDWATER REGULATING VALVE FOR THE BOILER WAS EXCESSIVELY LEAKING WATER. 74SOLAS(04)II-1/32.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2020
Resolved 11 February 2020
Resolution: Received class report stating that the deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 February 2020 Resolved
09211 - NO CHANGE SHALL BE MADE TO THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT, AND OTHER ITEMS COVERED BY THE SURVEY WITHUOT SANCTION OF THE ADMINISTRATION. PSCO DISCOVERED A PATCH ON THE RETURN STEAM LINE FOR THE NO. 1 WASTE OIL TANK. 74SOLAS(14)I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2020
Resolved 11 February 2020
Resolution: Received class report stating that the deficiency was rectified.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 21 June 2019 Resolved
Ships of 3,00 GT and over shall be provided with at least six water closets. The vessel has a clogged in the sewage piping system that only leaves one operable water closet for a crew of 21 persons. Action tacke: 15ac Ports and Waterways Safety Act 46 USC Ch.700 Sec. 7002 ILO 147 Pg. 36
Action required: 15 - Rectify deficiencies by next port
Resolved 27 June 2019
Resolution: Recieved KR survey report attesting to the proper operation of the vessel's sewage system.
Electrical › Electric Supply System (service) › Cable
Issued 28 January 2016 Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. Int the crew and officer's laundry rooms, the laundry machine's electrical supply cords are spliced and taped. 74SOLAS (04 CONS) II-1/40.1.3 Action taken: 10(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Vessel electrictians were able to replace the spliced cable with the proper connections.

Ownership record