MAURY USCG vessel records
← All vessels

KATE

Built
1970
Last inspected
29 January 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 January 2020
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG7318
104555
Flag
UNITED STATES
Maury page id
psix-104555

Documentation record

Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 9 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

29 January 2020 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6899295
2 October 2019 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6828347
10 September 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6808662
28 January 2019 Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6615810
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512553
2 April 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6383648
12 March 2018 Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6370046
14 April 2017 Internal Structural Exam · Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6220717
30 March 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5843416

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019 Resolved
Berthing area emergency escape hatch has been fitted with a large air conditioning unit on the top. While operable the hatch is extremely heavy. the air conditioner must be moved so that the hatch is clear at all times.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2019
Resolution: Escape hatch has been replaced and the air conditioner has been relocated.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 2 October 2019 Resolved
The vessel owner claims that there is a roving watch during all hours while the vessel is underway, but there is no program in place that outlines the role of the night time watch. Owner must create a written procedure for night watch and crew training.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 October 2019
Resolution: Owner has created a night watch program to include, training, logs, and written proceedures.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019 Resolved
Emergency escape hatches are not properly marked. Owner must mark.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 October 2019
Resolution: All emergency escape routes have been preoperly marked and lit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2019 Resolved
The wheelhouse serves as a berthing area for the Captain during overnight trips. This reclassifies that space as accommodations as apposed to operating station. The current 10B:C fire extinguisher required for operating station, must be upgraded to a 40 B:C as required in an accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 October 2019
Resolution: New 40 B:C extinguisher has been installed in the wheelhouse.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V), no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 29 March 2019
Communications › Radio Communications › EPIRB
Issued 14 April 2017 Resolved
EPIRB batter is expired. Repare/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2017
Resolution: New EPIRB was provided and registered prior to the completeion of the exam. Corrected on the spot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 April 2017 Resolved
Vessel high level alarm for the "tank space" is inoperable.Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2017
Resolution: Alarm panel was replaced, and tested prior to completeion of the exam, corrected on the spot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 April 2017 Resolved
Bilge high level audio alarm is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2017
Resolution: Bell activator was renewed prior to completeion of the exam. Corrected on the spot.
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2017 Resolved
Remote fuel shut-off valve is not marked. Mark per CFR.
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 5 May 2017
Resolution: Valves were properly marked.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 April 2017 Resolved
Alcohol test strips are expired. Renew.
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 5 May 2017
Resolution: New test kits were provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 14 April 2017 Resolved
FCC safety radio cert is expired. Provide new cert.
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 5 May 2017
Resolution: New cert was provided.
Lifesaving › Lifefloat › Netting
Issued 14 April 2017 Resolved
Life float net and webbing is damaged. Repair/renew.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 5 May 2017
Resolution: new life float was provided.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 14 April 2017 Resolved
waste management plan was not onboard. Provide.
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 5 May 2017
Resolution: plan was provided and posted.

Ownership record