← All vessels
KALLISTI
Freight Ship · Bulk Carrier class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named KALLISTI
KALLISTI is a 2009 freight ship. The Coast Guard has recorded 28 inspections since 2010, most recently in February 2026, along with 10 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 2010 to 2026. Most recent: inspection, 25 February 2026.
- Built
- 2009
- Last inspected
- 25 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9449340 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A7080
1045557
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1045557
Inspections, by type
…with no type recorded9
Years with a record
10 calendar years (2010–2026)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23456 - Convention (Subpart B), Gross Ton
13210 - Convention (Subpart B), Net Ton
37763 - Dead Weight, Metric Ton
47072 - Displacement, Metric Ton
13210 - Convention (Subpart B), Net Ton
37763 - Dead Weight, Metric Ton
47072 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
25 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8316409
30 October 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8260933
29 July 2025
Deficiency Check · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8175408
6 July 2025
COE-Administrative
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8187588
15 April 2023
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7665972
11 April 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7666500
11 February 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7635453
9 February 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7634537
29 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7185593
12 November 2020
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7093831
4 November 2018
COE-Offshore
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6574926
4 November 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6575324
9 August 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6506087
6 August 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6502300
21 December 2017
COE-Dockside · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6325118
6 July 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6191670
4 July 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6196989
10 May 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5868784
13 February 2016
ISPS III Exam · COE-Dockside
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5812195
12 February 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5814588
12 February 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5818280
1 February 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4236244
17 January 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4220459
12 January 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4220458
14 October 2010
ISPS I Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3869790
14 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3870230
13 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3869161
7 January 2010
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3655991
Deficiency record · 10
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 July 2025
Resolved
THERE SHALL NOT BE LESS THAN TWO SOURCES OF POWER FOR THE ELECTRICAL EQUIPMENT USED IN THE OPERATION OF THE FIXED FIRE DETECTION AND FIRE ALARM SYSTEM, VESSEL'S DETECTION SYSTEMS'S SOURCE OF POWER WAS LIMITED TO ONE, WITH A FLAG DISPENSATION LETTER TO HAVE IT CORRECTED BY 29JUL2025, VESSEL NOT ABLE TO REPAIR ON THIS DATE.
74SOLAS(20) CH. II-2 REG. 7.2.2
FSS CODE CH.9 REG 2.2.1
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 29 July 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 July 2025
Resolved
ALL DETECTORS SHALL BE OF A TYPE SUCH THAT THEY CAN BE TESTED FOR CORRECT OPERATION AND RESTORED TO NORMAL SURVEILLANCE. SMOKE DETECTORS WERE UNOPERATIONAL DURING THE INITIAL EXAMINATION.
74SOLAS(20) CH. II-2 REG. 7.2.2
FSS CODE CH.9 REG. 2.3.1.6
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 August 2018
Resolved
In addition to complying with specific provisions for fire integrity of bulkheads and decks of cargo ships, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and 9.6. Bottom 18 inches of insulation in CO2 room was damaged and removed from the space.
Fire Fighting › Combustible Materials › Linings
Issued 6 July 2017
Resolved
0750-Fire prevention- The following functional requirements shall be met; means shall be provided to control leaks of flammable liquids. PSCO observed lagging under the fuel oil purifier was covered in fuel oil. 74 SOLAS (2004) II-2/4.1 16ac
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 6 July 2017
Resolved
9900-Other (Not clearly hazardous)- The plan must included detailed fouling maintenance and sediment removal procedures. The PSCO observed growth on the hull under the water line. 33CFR151.2050 40 c
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 10 May 2016
Resolved
9900 - Other (not clearly hazardous)- The means acceptable to the Administration shall be maintained in proper condition to ensure continued accurate functioning in service. Crew has attached a fabricated gagging device on the MDO. settling tank, MDO service tank, L.O. gravity tank, and Main Engine L.O. settling tank that prevents the valve from closing as designed. SOLAS 74(2004)II-2/4.2.2.3.5.3
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 May 2016
Resolved
0660- Lifejackets- Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO while conducting the engine room inspection noticed only one life jacket in the Engine Control Room where two are to be stowed per the Safety Plan. SOLAS 74(2004)III-20.1
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 17 January 2012
Resolved
9900-Other (not clearly hazardous)-Each bunker line transfer pipe must be tested annually and not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel conducted annual test however air was used as a medium.- 33CFR155.820
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 14 October 2010
Resolved
1410: ABS Classification Society and Port State Control inspectors attended vessel. Class/PSC witnessed dead slow ahead/astern test from local and bridge control on MGO fuel; engines were found to be working properly. ABS to provide class survey report prior to departing Anchorage 9.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.