MAURY USCG vessel records
← All vessels

MTM MISSISSIPPI

MTM MISSISSIPPI is a 2006 tank ship. The Coast Guard has recorded 10 inspections since 2017, most recently in May 2026, along with 2 deficiencies and 1 operational control.

Records from 2017 to 2026. Most recent: operational control imposed, 26 May 2026.

Built
2006
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9315056
9V9266
1045862
Flag
SINGAPORE
Maury page id
psix-1045862

Documentation record

Tonnage as PSIX records it30152 - Convention (Subpart B), Gross Ton
13648 - Convention (Subpart B), Net Ton
614193 - Displacement, Metric Ton
51182 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

26 May 2026 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8381297
1 December 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8271842
6 October 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8013781
12 October 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7804439
4 August 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7524860
9 July 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7501590
19 May 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7453932
19 November 2019 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6853531
23 October 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6564420
24 September 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6273528

Deficiency record · 2

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2023 Resolved
Ships shall be maintained in compliance with the structural requirements of a classification society which is recognized by the administration. Cargo tanks 6 port, 4 port, 3 port and 1 port are leaking cargo vapors and inert gas. 74 SOLAS 04 II-1 / 3-1
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
Resolution: Ship's crew members tightened the fittings around the locations where the vapors where escaping.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 12 October 2023 Resolved
Protective equipment shall not be kept within accommodation spaces. 02 Chemical suits were stowed in the air conditioning room. 74 SOLAS 20 VII / 10 IBC Code 14.1.2
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
Resolution: Ship's crew moved the equipment to SMPEP locker.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.